OLYMPUS RecMic II RM-4110S Standard Kit User Guide
- June 12, 2024
- Olympus
Table of Contents
RecMic II RM-4110S Standard Kit
User Guide
RecMic II Configuration Guide: Microsoft PowerPoint
Making PowerPoint presentations can certainly take some time. Whether you are pre-recording your presentation or planning to present live, a high-quality recording device is essential. The RecMic II from Olympus captures natural speaking voices with its noise filtration technology. Easily record the audio for your presentation without breath or outside noise as well as dictate your slide notes without having to type. Increasing your productivity within Microsoft PowerPoint is easy. Assign functions, or short-keys, to the RM-4010P to make creating your presentation more efficient.
Tutorial
Button Modes
The RecMic series comes with preset button modes which are configured for
Windows.
Position | Olympus Mode | Description |
---|---|---|
F1 | Custom Mode | Default setting used for Olympus Software. |
F2 | Dragon Mode | Custom setting is offered via the RecMic Configuration Tool. |
F3 | Windows Mode | Button setting is optimized for Dragon Software from Nuance. |
F4 | Preset Button Modes | Button setting is optimized for Windows Speech |
Recognition.
How to Change Modes.
****Press the NEW and INSERT button as you see in on the right. LEDs from F1 to F4 will flash for 15 seconds. During this time, choose your preferred preset button modes from F1 to F4. For windows select F4.
Recording Mode
In order to achieve good recording quality for your PowerPoint narration, it is important that you elect the preset recording mode which matches to your enviornment. The recording mode controls the directionality and the noise reduction level during recording. Especially during speech recognition, the background noise should be kept at a minimum level. It is recommended that users use the default mode.
LED Color | Recording Mode | Settings |
---|---|---|
Directionality | Noise Cancellation | Intelligent Auto Mode |
Blue | Quiet Environment (Default) | OFF |
Green | Noisy Environment for Speech Recognition | HIGH |
Red | Noisy Environment for Classic Dictation | HIGH |
Purple | Customized setting (ONLY via SDK) | OFF, LOW, MID, HIGH |
HIGH | ON/OFF |
Directionality:
Noise cancellation:
Intelligent Auto Mode
This feature continuously monitors the input level and variably adjusts the
recording level to the optimal level.
Input level too low: Increases recording level
Input level too high : Reduces recording level
How to Change Modes.
Press the F1 and INSERT button for more than 5 seconds as shown. By repeating this operation, it will toggle between the modes.
RecMic Configuration Tool
Download link: https://dl-support.olympus-imaging.com/odms_download/rct-
olympus-recmic_configuration_tool/en/
Although it is recommended that users use the default settings, you can adjust
your RecMic based on your recording environment for the best results. RecMic
Configuration Tool is software that supports the workflow by using RecMics to
control desktop applications. With this software you can configure RecMic
settings and assign functions that control applications to RecMic buttons. The
application is free and can be downloaded from each local Olympus Websites.
The tool supports the following features: Device Configuration
- Recording Mode Setting
- Mouse Control Setting
- Custom Keyboard Setting
- Firmware Update
- Other General Setting
Application Control
- Edit Command
- Start Application Command
- Text Command
- Shortcut Command
- Waiting Command
- Keyboard Template
In the Device Configuration tab, you can configure various settings for the
microphone, mouse, and buttons. When you start RecMic Configuration Tool, the
current settings of the connected device are automatically downloaded. Only
the options that can be used on the connected device are shown in the screen.
You can customize the behavior of the device to suit your preferences by
uploading the changed settings to the device.
In the Application Control tab, you can assign various functions to each
button, such as to start up specified applications, to send keyboard shortcuts
or text to applications. Furthermore, this software also supports commands for
controlling Dragon speech recognition software from Nuance. By setting the
functions assigned to each button to different applications, you can execute
complex operations easily and quickly by just clicking RecMic buttons.
Device configurations and application control configurations can be saved in
files. You can reproduce these settings on other computers by importing these
files.
Record a Slide Show with Narration and Slide Timings
Download link: https://support.microsoft.com/en-us/office/record-a-slide-
show-with-narration-and-slide-timings0b9502c6-5f6c-40ae-
b1e7-e47d8741161c#:~:text=On%20the%20Insert%20tab%2C%20in,sound%2C%20and%20then%20click%20OK
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>