Package Contents

Fanvil i20S Indoor SIP Door Phone -figure 1

 Physical Specifications

Device size 160 x 93 x 35 mm
Weight 420g (gross weight)
  1.  Front Panel
    Fanvil i20S Indoor SIP Door Phone -figure 2
Interface Description
Speaker The door phone has a built-in speaker for convenient communication

and alert use.
MK| The door phone has a built-in microphone hidden in the pinhole located on the front panel.
RFID Reader| Use RFID cards to unlock the door by touching the RFID reader of the device.

Button Definition

Button Description
DSS Key Press the Button, calling or requesting to open the door.
Numeric Keyboard Input password to open the door or call.

LED Definition

LED Status Description

| Steady Blue| Door unlocking
off| Door locking

| Blinks per second| Call Hold or Ringing
off| On-Hook
 Blinks every 3 seconds| The device in the issuing state
Steady Blue| Online talking

| Blinks per second| Network error
off| The network is normal, SIP is not registered
Blinks every 3 seconds| SIP Registration failed
Steady Blue| SIP Registration succeeded
2. Port Definition
After removing the Back Panel of i20S, there is one terminal block connector for power and lock control connection
as shown in the picture below.

Fanvil i20S Indoor SIP Door Phone -figure 3

Network ConnectorFanvil i20S Indoor SIP Door Phone -figure
5 Power and Electric-lock Connect.Fanvil i20S
Indoor SIP Door Phone -figure 6

1 2 3 4 5 6 7
+DC12V VSS NC COM NO S-IN S-OUT
12V DC Input Electric-lock switch Indoor switch

JP1 Jumper
There are two modes for power supply of electric-lock as shown in the picture below.
(The default is “Passive Mode”).
Passive Mode: When the electric-lock starting current is more than 12V/500mA, need to use the external drive mode, the electric lock interface for short circuit output control.
Active Mode: When the electric-lock starting current is less than 12V/500mA, can use the internal drive mode, the electric lock interface is 12V DC output.

| |
---|---|---

Wiring instructions
NO: Normally Open Contact
COM: Common Contact
NC: Normally Close Contact

Driving Mode Electric-lock Mode JP1Jumper Connections
Active Passive No electricity
when open Electrify
when open

13](https://manuals.plus/wp-content/uploads/2021/11/Fanvil-i20S-Indoor-SIP- Door-Phone-figure-13.png)
√| | | √| | Fanvil i20S Indoor SIP Door Phone -figure
14
| √| √| | | Fanvil i20S Indoor SIP Door Phone -figure
15
| √| | √| | Fanvil i20S Indoor SIP Door Phone -figure
16
| √| √| | | Fanvil i20S Indoor SIP Door Phone -figure
17

Installation

Fanvil i20S Indoor SIP Door Phone -figure 18

Step 1: Installation preparation
A. Check the following contents:

  • Hex wrench x 1
  • RJ45 plugs x 2 (1 spare)
  • KA4 x 25mm screws x 4
  • 25mm screw anchors x4

B. Tools that may be required:

  • Hex wrench
  • Phillips screwdriver (Ph2 or Ph3), hammer, RJ45 crimper
  • Electric impact drill with a 6mm drill bit

Step 2: DrillingFanvil i20S Indoor SIP Door Phone -figure
19

A. Place the mounting template with dimensions on the surface of a wall in a desired flat position.
B. Use an electric drill to drill the 4 holes marked on the mounting template. It is recommended to drill about 30mm deep. Remove the template when finishing drilling.
C. Push or hammer screw anchors into the drilled holes.

Step 3: Removing hanging shell
A. Remove the hanging shell in Figure 3 and Figure 4.

|
---|---

B. With Phillips screwdriver, unpacks the Back Panel and the main part of intercom as shown in Figure 5.Fanvil i20S Indoor SIP Door Phone -figure
22

Step 4: Hanging shell Fixing and CablingFanvil i20S Indoor SIP Door
Phone -figure 23

A. Select the hole for cable supply; cable length of 15cm to 20cm is recommended.
B. With 4 KA4 x 25mm screws, tighten the Wall-mounted hanging shell as shown in Figure 6.

Step 5: Connection lineFanvil i20S Indoor SIP Door Phone -figure
24

A. Select the hole for cable supply.
B. Connect the cables of RJ45, power, and electric lock to the motherboard socket as mentioned in the connector’s description (refer to Section 2).
C. Test whether there is electricity by doing the following:
Press the # button for 3 seconds to get the IP address of the intercom by voice.
Input access password or press the indoor switch to check the electric-lock installation.
Note: Do not proceed to mount until you have finished the electric checking.

Step 6: MountingFanvil i20S Indoor SIP Door Phone -figure
25

A. Use the 4 screws to tighten the main part of the intercom on the back panel as shown in Figure 9.
B. Push the device into the Wall-mounted hanging shell and tighten it with 1 screw as shown in Figure 10.
C. Make sure the screws have been tightened properly for a better waterproof effect.

Searching Door Phone

There are two methods as shown below to search the i20S.
Method 1:
Open the door phone Network Scanner. Press the Refresh button to search the i20S and find the IP address.
(Download address http://download.fanvil.com/tool/iDoorPhoneNetworkScanner.exe )Fanvil i20S
Indoor SIP Door Phone -figure 26

Method 2:
Press and hold the “#” key for 3 seconds and the door phone will report the IP address by voice.Fanvil i20S Indoor SIP Door Phone -figure
27

Default Setting

Default DHCP Client| On
Static IP Address| 192.168.1.179
Default Web Port| 80
Default Login User Name| admin
Default Login Password| admin
Display IP address| Hold 4$ for 3 seconds to display by voice
Search Tools| iDoorPhone Network Scanner

SIP Door Phone Setting

Step 1: Log in to the homepage of the i20S.Fanvil i20S Indoor SIP Door
Phone -figure 28

Step 2: Add the SIP account.
Set SIP server address, port, user name, password, and SIP user with assigned SIP account parameters.
Select “Activate”, and then click Apply to save this setting.Fanvil i20S
Indoor SIP Door Phone -figure 29

Step 3: Setting DSS key
Set the DSS key as shown below for a quick start. Click “Apply” to save this setting.
Type: Hot Key
Number 1: The DSS Key will dial to this Number 1.
Number 2: If Number 1 is unavailable, it will be forwarded to Number 2.
Line: Working line
Subtype: Speed dialFanvil i20S Indoor SIP Door Phone -figure
30

Step 4: Door Phone SettingFanvil i20S Indoor SIP Door Phone -figure
31

Door Unlocking Setting

Local

  1. Local Password
    Step 1: Go to EGS Setting → Features → Set Local Password (The default is “6789”).
    Step 2: Use the device’s Numeric Keyboard to input the password and “#” key, and then the door will be unlocked.
    Fanvil i20S Indoor SIP Door Phone -figure 32

  2. Private Access Code
    Step 1: Go to EGS Access → Access Rule → set Access Code.
    Step 2: Use the device’s Numeric Keyboard to input the password and “#” key, and then the door will be unlocked.

Fanvil i20S Indoor SIP Door Phone -figure 33

Remote
Remote Password
Step 1: Go to EGS Setting → Features → Set Remote Password (The default is “”).
Step 2: To answer the call made by the visitor via SIP phone, press the “
” key to unlock the door for the visitor.

Fanvil i20S Indoor SIP Door Phone -figure 34

RFID Card
Step 1: Go to EGS Access → Enter the Name and ID Number (Only Front 10 yards) → Press Add to Access Table.
Step 2: Use pre-assigned RFID cards to unlock the door by touching the RFID area of the device.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals