Anolis Calumma S MC LED Lighting User Manual
- June 9, 2024
- ANOLiS
Table of Contents
A ROBE Business
Calumma S MC
Calumma S SC
LED Lighting
User Manual Version 1.1
Calumma S MC LED Lighting
QR code for user manual https://www.anolislighting.com/resource/calumma-s-mc- user-manual
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY
BEFORE POWERING OR INSTALLING YOUR Calumma !
Save it for future reference.
This device has left our premises in absolutely perfect condition. In order to
maintain this condition and to ensure safe operation, it is absolutely
necessary for the user to follow the safety instructions and warnings written
in this manual.
The manufacturer will not accept liability for any resulting damages caused by
the non-observance of this manual or any unauthorized modification to the
device.
Unauthorized modification will void warranty.
Safety instructions
DANGEROUS VOLTAGE CONSTITUTING A RISK OF ELECTRIC SHOCK IS PRESENT WITHIN THIS
UNIT!
This fixture should be operated only from the type of power source indicated
on the marking label. If you are not sure of the type of power supplied,
consult your authorized distributor or local power company.
Always disconnect the fixture from AC power before servicing or cleaning.
Make sure the power/data cable is not damaged by sharp edges.
Do not install the unit near an open flame.
Refer servicing to qualified service personnel.
This fixture falls under protection class I. Therefore this fixture has to be
connected to a mains socket outlet with a protective earthing connection.
Do not connect this fixture to a dimmer pack.
LED light emission. Risk of eye injury. Do not look into the beam from a short
distance without suitable protective eyewear. Do not look at LEDs with
magnifiers or similar optical instruments that may concentrate the light
output.
The fixture was designed for outdoor use. This fixture must not be used for
underwater installation.
When choosing the installation spot, please make sure that the fixture is not
exposed to extreme heat or dust.
Avoid using the unit in locations subject to possible impacts.
The fixture body never must be covered with cloth or other materials when the
fixture is under operation.
Only operate the fixture after having checked that the housing is firmly
closed and all screws are tightly fastened.
The fixture becomes hot during operation. Allow the fixture to cool
approximately 30 minutes prior to servicing or maintenance.
Operate the fixture only after having familiarized yourself with its
functions. Do not permit operation by persons
not qualified to operate the fixture. Most damages are the result of
unprofessional operation!
Immunity of the equipment is designed for electromagnetic environments E1, E2,
E3 according to the standard
EN55103-2 ed.2 Electromagnetic compatibility. Product family standard for
audio, video, audiovisual and
entertainment lighting control apparatus for professional use. Part 2:
Immunity.
The product (covers and cables) must not be exposed to a high frequency
electromagnetic field higher than 3V/m.
The installation company should check levels of possible interferences above
the tested levels E1,E2,E3 given by this standard (e.g. transmitters in
surrounding area) before installing the equipment.
Emission of the equipment complies with the standard EN55032 Electromagnetic
compatibility of multimedia equipment – Emission Requirements according to
class B.
Please consider that unauthorized modifications on the fixture are forbidden
due to safety reasons!
Please use the original packaging if the fixture is to be transported.
If this device will be operated in any way different to the one described in
this manual, the product may suffer damages and the warranty becomes void.
Furthermore, any other operation may lead to dangers like short-circuit,
burns, electric shock etc.
Fixture exterior view
- Transparent glass cover
- Mounting yoke
- Tilt adjusting lock
- LED module with heat sink
Installation
3.1 Mounting the fixture
The Calumma S can be fastened in any orientation on a flat, non-flammable
surface by means of mounting yoke (2).
The LED module (4) can be tilted +180°/-180°. Use an Allen key 2.5 for
adjusting a LED module position.
Ensure that the structure to which you are attaching the fixture is secure.
3.2 Connection to mains
The unit must be installed by a qualified electrician in accordance with
all national and local electrical and construction codes and regulations.
This device falls under class one and must be grounded!
The Calumma is equipped with auto-switching power supply that automatically
adjusts to any 50/60Hz AC power source from 120-277 Volts.
3.2.1 Junction box installation
The junction box box falls under protection class I . Therefore, every
junction box has to be connected to a mains socket outlet with a protective
earthing connection.
-
Unscrew the four screws (1) from the cover (2) on the junction box to get access to the terminal block (3) and two mounting holes of diameter of 4.6 mm (4).
-
Screw the junction box on a non-flammable flat surface.
-
Connect cables.
The cable gland M20 x 1.5 with a standard seal serves for a cable of diameter of 7-13mm, for smaller diameter of cable (4-8mm) you have to remove the original seal from the cable gland M20x1.5 and use the enclosed reducing seal instead of it. The reducing seal for diameter of cable 4-8mm (P/N 13051388) is enclosed in the Junction box. Remove the end cap from the cable gland before passing the cable.
We recommend to apply an adequate layer of the paste LOCTITE 5331 on the plastic holder of the cable gland before inserting it into the body of the gland and an adequate layer of the paste LOCTITE 577 on the thread of the gland body.
Cable gland M20x1.5: -
Screw the cover (2) back on the junction box.
Control and connection options
4.1 DMX or DALI
Example
DMX connection (CE)
IF the 5-cored cable Flamar 3x AWG 16 + 1x (2x AWG 24), (P/N 1305 1508) is
used for Calumma connection and connection among junction boxes:
Core | Connection | Core | Connection |
---|---|---|---|
Black | Live (L) | Red | Data + (+) |
Blue | Neutral (N) | White | Data – (-) |
Yellow/Green | GND **** | Shielding | Data ground (0V) |
Up to 32 Calummas can be connected in DMX chain.
DALI connection
IF the 5-cored cable SJTW 5x 14AWG (P/N 1305 3336) is used for Calumma
connection and connection among junction boxes:
Core | Connection | Core | Connection |
---|---|---|---|
Black | Live (L) | Red | Data |
White | Neutral (N) | Orange | Data |
Yellow/Green | GND **** |
Up to 64 Calummas can be connected in DALI network.
4.2 Power On/Off
Note: This type of connection is available for Pure White version only.
Non dimmable.
4.3 DMX or Ethernet via E-box
The E-box menu allows you to switch connected Calummas to the two modes:
Standard – LED modules are switched to an internal serial connection. DMX
addressing of connected LED modules is made automatically (default DMX address
= 1, changes can be done by the E-box menu or by RDM). The Standard mode is
set as default.
Pass-Thr – (Pass through). LED modules are switched to an internal
parallel connection. DMX addressing of connected LED modules has to be done
manually by means of the Robe Universal Interface (or its wireless version
Robe Universal Interface WTX) and the software RDM Manager.
Example with junction boxes
Pass Through mode is intended for this connection. Max. 32 fixtures can be
connected to one LED output of the EBox (Star, Daisy, Lite) in this mode.
CE version
IF the 5-cored cable Flamar 3x AWG 16 + 1x (2x AWG 24), (P/N 1305 1508) is
used for Calumma connection and connection among junction boxes:
Core | Connection | Core | Connection |
---|---|---|---|
Black | Live (L) | Red | Data + (+) |
Blue | Neutral (N) | White | Data – (-) |
Yellow/Green | GND **** | Shielding | Data ground (0V) |
US version
IF the 6-cored cable SJTW 6x 14AWG, (P/N 1305 3480) is used for Calumma
connection and connection among junction boxes:
Core | Connection | Core | Connection |
---|---|---|---|
Black | Live (L) | Red | Data + (+) |
White | Neutral (N) | Orange | Data – (-) |
Yellow/Green | GND **** | Blue | Data ground (0V) |
Number of connected Calummas to one E-box output depends on a cable length,
power voltage, type of Calumma and E-box operation mode.
The tables below state max. theoretical number of Calummas connected to the
one LED output of the E-box.
Table for Pass-Through mode of E-boxes.
Calumma S MC | Voltage |
---|---|
**Cable length *** | 120V |
10 m | 32 |
20 m | 32 |
30 m | 32 |
50 m | 26 |
70 m | 18 |
100 m | 13 |
200 m | 6 |
500 m | 3 |
Calumma S SC | Voltage |
--- | --- |
**Cable length *** | 120V |
10 m | 32 |
20 m | 32 |
30 m | 32 |
50 m | 26 |
--- | --- |
70 m | 18 |
100 m | 13 |
200 m | 6 |
500 m | 3 |
- Cable length is a total cable length between power supply (e.g. E-box) and last connected Calumma.
Example: Total cable length=L1+L2+L3+L4+L5+L6
Software update
Software update of Calumma module has to be done by means of the software ROBE
Uploader running on PC.
The ROBE Uploader is a software for automatized software update of ROBE
fixtures. The ROBE Uploader switches Calummas to the update mode
automatically.
Please see https://www.robe.cz/robe-uploader/ for more information.
The software update depends on a method of Calummas connection.
Note: Calumma modules in DALI connection and ON/OFF connection cannot be
updated.
DMX or Ethernet connection via E-box
If the option Standard is selected from the menu E-box mode, the E-box will be
updated including connected Calumma modules. You have to use the file
EminereEbox.lib in the ROBE Uploader for this operating mode.
The Standard mode is usually used in IN/OUT connection (without junction
boxes).
If the option Pass-Thr is selected from the menu E-box mode, the E-box will
not be updated, only connected Calumma modules. You have to use the file
Calumma.lib in the ROBE Uploader for this operating mode.
The Pass-Through mode is usually used in connection with junction boxes.
Examples:
- By means of DMX connection and RUNIT. Connection via junction boxes.
- By means of the Ethernet connection. Connection via junction boxes.
If you use a connection via junction boxes and you need to update connected
E-box, switch the E-box to the Standard mode and use the EminereEbox.lib in
the ROBE Uploader to update E-box. After updating the E-box, switch it back to
the Pass-Trough mode.
DMX connection
For updating of Calumma modules, use the file Calumma.lib.
Technical specifications
Power supply
-
Electronic auto-ranging
-
Input voltage: 120 – 277V AC, 50/60 Hz
-
Power consumption:
Calumma S MC: 30 W
Calumma S SC: 30 W -
Inrush current:
Calumma S MC: 60A/230VAC, 30A/115VAC
Calumma S SC: 60A/230VAC, 30A/115VAC
Optic
-
Light source:
Calumma S MC: 3 x high power multichip LEDs
Calumma S SC: 19 x high power single chip LEDs -
Colour variants: RGBW (W – 6500 K), RGBA, PW (W – 3000 K)
-
Beam Angle Calumma S MC:
Symetrical: 9°, 15°, 25°, 30°, 45°, 65°, 100°
Bi-symetrical: 10° x 30°, 30° x 10°, 10° x 60°, 60° x 10°, 15° x 45°, 45° x 15°, 15°x90°, 90°x15°, 30°x60°, 60°x30°, 30°x90°, 90°x30° -
Beam Angle Calumma S SC:
Symetrical: 10°, 15°, 25°, 30°, 45°, 65°, 100°
Bi-symetrical: 10° x 30°, 30° x 10°, 10° x 60°, 60° x 10°, 15° x 45°, 45° x 15°, 15°x90°, 90°x15°, 30°x60°, 60°x30°, 30°x90°, 90°x30°
Asymmetrical side, Asymmetrical forward -
Projected Lumen Maintenance: L90B10 >90.000 hrs, Ta = 25°C / 77°F
Compatible drivers
-
E-box Daisy
1 Output
1 Main power Input
Control: DMX, Art-Net, sACN , W-DMX control, RDM
Pixel control
120-277V Input
Connection via terminal blocks, inlets via grommet
IP67 -
E-box Star
6 outputs
1 Main power Input
Control: DMX, Art-Net, sACN , W-DMX control, RDM
Pixel control
120-277V Input
Connection via terminal blocks, inlets via grommet
IP67 -
E-box Lite
1 output
1 Main power Input
Control: DMX, W-DMX control, RDM
Pixel control
120-277V Input
Connection via screw terminal blocks, inlets via grommet
IP67
Mounting method
- Via yoke
- Adjustability: -180°/+180°
Housing
- High pressure die-cast aluminium body
- Tempered glass
Cooling system
- Convection
Total heat dissipation
- Calumma S MC: 77 BTU/h (calculated)
- Calumma S SC: 77 BTU/h (calculated)
Protection factor
- CE: IP 67 (IP 66 junction box)
- US: Suitable for wet location
Impact rating
- IK10
Operating ambient temperature range
- -20°C /+40°C (-4°F /+104°F)
Connection – CE
-
DMX connection
Calumma IN: Flamar 3x AWG 16 + 1 x (2x AWG 24), Standard 1m with bare-end (P/N 1305 1508)
Interconnecting cables: Flamar 3x AWG 16 + 1 x (2x AWG 24) (P/N 1305 1508)
Junction box (P/N 1098 0714) -
DALI connection
Calumma IN: SJTW 5x 14AWG, standard 1m with bare-end (P/N 1305 3336)
Interconnecting cables: SJTW 5x 14AWG (P/N 1305 3336)
Junction box (P/N 1098 0714) -
DMX or Ethernet via E-box and Junction box
Calumma IN: Flamar 3x AWG 16 + 1x (2x AWG 24), standard 1m with bare-end (P/N 1305 1508)
Interconnecting cables: Flamar 3x AWG 16 + 1 x (2x AWG 24), (P/N 1305 1508)
Junction box (P/N 1098 0714)
Connection – US
-
DALI connection
Calumma IN: SJTW 5x 14AWG, standard 1m with bare-end (P/N 1305 3336)
Interconnecting cables: SJTW 5x 14AWG (P/N 1305 3336)
Junction box (P/N 1098 0714) -
DMX or Ethernet via E-box and Junction box
Calumma IN: SJTW 6x 14AWG ,standard 1m with bare-end (P/N 1305 3480)
Interconnecting cables: SJTW 6x 14AWG ,(P/N 1305 3480)
Junction box (P/N 1098 0714)
Weight
- Calumma S SC: 3.44 kg (7.6 lbs)
- Calumma S MC: 3.68 kg (8.11 lbs)
Dimensions (All dimensions in mm [inch])
|
Junction box
---|---
Included items
- 1 x Calumma S MC / Calumma S SC
- 1 x User manual
Optional accessories
Top Hat Calumma S RAL9011 (P/N 10980733)
Half Top Hat Calumma S RAL9011 (P/N 10980737)
Tenon Adaptor for Calumma S
Pole Mount Bracket for Calumma S
E-box Daisy (P/N 10063655)
E-box Daisy/W (P/N 10063638)
E-box Lite (P/N 10063657)
E-box Lite/W (P/N 10063653)
E-box Star (P/N 10063656)
E-box Star/W (P/N 10063644)
Cleaning and maintenance
DANGER!
Disconnect from the mains before starting any maintenance or cleaning work
Rinse off loose dirt with low pressure water spray. Wash the housing with a
soft brush or sponge and a mild, nonabrasive washing detergent. Rinse it.
Maintenance and service operations are only to be carried out by a qualified
person.
Should you need any spare parts, please use ROBE OEM parts.
7.1 Disposing of the product
To preserve the environment please dispose or recycle this product at the end
of its life according to the local regulations and codes.
ChangeLog
This section summarizes changes in the user manual.
Version of manual | Date of issue | Description of changes |
---|---|---|
1.1 | 12/10/2022 | DMX chart ver.1.1 added |
DMX protocol for Calumma – All sizes – RGBW(A)
Version: 1.1 (16 modes in total)| | |
Mode/Channels in all| Mode 1- RGBW(A)-8bit, Mode 2- RGB 8-bit,
Mode 3- full RGBW(A)|
1| 2| 3| 4| 5| 6| 7-10| Mode 4- White-
full control, Mode 5- Reduced RGBW(A)|
4| 3| 12| 3| 6| 8| Reserved| Mode 6- Reduced RGBW(A)+white control|
| | | | | | | RGBW/RGBA/RGB modes|
Mode/channels| DMX Value| Function| Type of control
1| 2| 3| 4| 5| 6
1| 1| 1| –| 1| 1| | Red|
| | | | | | 0 – 255| Red LEDs saturation control (0-100%)| proportional
–| –| 2| –| –| –| | Red Fine|
| | | | | | 0 – 255| Red LEDs saturation control fine| proportional
2| 2| 3| –| 2| 2| | Green|
| | | | | | 0 – 255| Green LEDs saturation control (0-100%)| proportional
–| –| 4| –| –| –| | Green Fine|
| | | | | | 0 – 255| Green LEDs saturation control fine| proportional
3| 3| 5| –| 3| 3| | Blue|
| | | | | | 0 – 255| Blue LEDs saturation control (0-100%)| proportional
–| –| 6| –| –| –| | Blue Fine|
| | | | | | 0 – 255| Blue LEDs saturation control fine| proportional
4| –| 7| –| 4| 4| | White (Amber)|
| | | | | | 0 – 255| White LEDs saturation control (0-100%)| proportional
–| –| 8| –| –| –| | White (Amber) Fine|
| | | | | | 0 – 255| White LEDs saturation control fine| proportional
–| –| 9| 1| –| 5| | Green correction|
| | | | | | 0| Uncorrected white| step
| | | | | | 1-127| Minus green – uncorrected white| proportional
| | | | | | 128| Uncorrected white (128=default)| step
| | | | | | 129-255| Uncorrected white – Plus green| proportional
–| –| 10| 2| –| 6| | Colour temperature
correction (CTC)|
| | | | | | 0| No function (0 – default)| step
| | | | | | 1 – 10| Tungsten dimming 2700 K| step
| | | | | | 11 – 20| Tungsten dimming 3200 K| step
| | | | | | 21-255| Colour temperature changing from 1800 K –> 6500 K|
proportional
| | | | | | | (21-1800K, 66-2700K, 91-3200K,141-4200K, 211-5600K, 255-6500K)|
–| –| 11| 3| 5| 7| | Dimmer|
| | | | | | 0 – 255| Light intensity coarse (0-100%)| proportional
–| –| 12| –| 6| 8| | Dimmer Fine|
| | | | | | 0 – 255| Light intensity fine| proportional
| | | | | | | |
Copyright © 2022 Robe Lighting s.r.o. – All rights reserved|
All Specifications subject to change without notice|
| | | | | | | |
DMX protocol for Calumma – All sizes – MC and SC
Version: 1.1 (16 modes in total)| | |
Mode/Channels in all| TW Modes: Mode 6- White selection + Dimmer, Mode
7- WW + CW|
11| 12| 13| 14-16| PW Mode: Mode 8- Dimmer|
3| 4| 2| Reserved| |
| | | | TW and PW modes|
Mode/channels| DMX Value| Function| Type of control
6| 7| 8
1| –| –| | White colour selection|
| | | 0 – 255| White from 2700 K – 6500 K| proportional
–| 1| –| | Warm White|
| | | 0 – 255| Warm White LEDs saturation control (0-100%)| proportional
–| 2| –| | Cool White|
| | | 0 – 255| Cool White LEDs saturation control (0-100%)| proportional
2| 3| 1| | Dimmer|
| | | 0 – 255| Light intensity coarse (0 – 100%)| proportional
3| 4| 2| | Dimmer Fine|
| | | 0 – 255| Light intensity fine| proportional
| | | | |
Copyright © 2022 Robe Lighting s.r.o. – All rights reserved|
All Specifications subject to change without notice|
| | | | |
Specifications are subject to change without notice.
October 12, 2022
Copyright © 2022 Robe Lighting – All rights reserved
Made in CZECH REPUBLIC by ROBE LIGHTING s.r.o. Palackeho 416/20 CZ 75701
Valasske Mezirici
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>