Anolis ArcPower 72 LED Lighting User Manual

June 3, 2024
ANOLiS

Anolis ArcPower 72 LED Lighting ArcPower 72 LED Lighting User ManualAnolis ArcPower 72 LED Lighting

ArcPower 72 LED Lighting

CAUTION!
Unplug mains lead before opening the housing!
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOU INITIAL START – UP!

Safety instructions

Every person involved with installation and maintenance of this product has to:

  • be qualilfied
  • follow the instructions of this manual

CAUTION!
Be careful with your operations. With a high voltage you can suffer a dangerous electric shock when touching the wires inside the unit!
This product has left our premises in absolutely perfect condition. In order to maintain this condition and to ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning notes written in this manual.
To prevent from danger of accident ,the device has to be fixed on flat, non-f lammable surface in compliance with the installing instruction included in this manual.
Important:
The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unauthorized modification to the product.
Always ground the unit.
The electric connection, repairs and servicing must be carried out by a qualified employee.
Do not connect this unit to a dimmer pack.
Use a source of AC power that complies with local building and electrical rules.AC power has to have both overload and short circuit protection

Operating determinations

This product was designed for indoor use only.
If the unit has been exposed to drastic temperature fluctuation (e.g. after transportation), do not switch it on immediately. The arising condensation water might damage your unit. Leave the unit switched off until it has reached room temperature.
Avoid brute force when installing or operating the unit.
When choosing the installation-spot, please make sure that the unit is not exposed to extreme heat, moisture or dust.
Only operate the unit after having checked that the housing is firmly closed and all screws are tightly fastened.
The maximum ambient temperature 40° C must never be exceeded.
Operate the unit only after having familiarized with its functions. Do not permit operation by persons not qualified for operating the unit. Most damages are the result of unprofessional operation!
Please use the original packaging if the product is to be transported.
Please consider that unauthorized modifications on the unit are forbidden due to safety reasons!
Immunity of the equipment is designed for electromagnetic environments E1, E2, E3 according to the standard EN55103-2 ed.2 Electromagnetic compatibility. Product family standard for audio, video, audiovisual and entertainment lighting control apparatus for professional use. Part 2: Immunity.
The installation company should check levels of possible interferences above the tested levels E1,E2,E3 given by this standard (e.g. transmitters in surrounding area) before installing the equipment.
Emission of the equipment complies with the standard EN55032 Electromagnetic compatibility of multimedia equipment – Emission Requirements according to class B.

Description of the ArcPower 72

  1. Power Indicator
  2. Control board
  3. DMX Output
  4. DMX Input
  5. LED Zone 1 output
  6. LED Zone 2 output
  7. RS 232 Output
  8. Fuse Holder
  9. Power Cord

Anolis ArcPower 72 LED Lighting - ArcPower 72 1

DMX Input
Pin 1: Not connected Pin 5: Not connected
Pin 2: +12V
Pin 6: Data +
Pin 3: Not connected Pin 7: Data Pin
4: Not connected
Pin 8: GND
RJ45 socket
Front view of the socket:
RS232 Input
9-pin D connector
Front view of the socket: RS232 Input
9-pin D connector
Front view of the socket: RS232 Input
9-pin D connector
Front view of the socket:

cAnolis ArcPower 72 LED Lighting - DyNet protocol 1

DMX Output
Pin 1: Not connected
Pin 2: Not connected
Pin 3: Not connected
Pin 4: Not connected
Pin 5: Not connected
Pin 6: Data +
Pin 7: Data
Pin 8: GND
LED module Input
Pin 1: Red LED +
Pin 2: Green LED +
Pin 3: Blue LED +
Pin 4: White LED +
Pin 5: Red LED –
Pin 6: Green LED
Pin 7: Blue LED –
Pin 8: White LED –
Pin 1: Not connected
Pin 2: Received Data
Pin 3: Transmitted Data
Pin 4:
Pin 5: Signal Ground
Pin 6:
Pin 7:
Pin 8:
Pin 9: Not connected

Installation

4.1.Connection to the mains
The ArcPower 72 is equipped with auto-switching power supply that automatically adjusts to any 50/60Hz AC power source from 100-240 Volts.
Carefully prepare the end of the the supply cord and fit a suitable plug.A 3-prong grounding-type plug must be
installed following the manufacturer´s instructions.The earth has to be connected!
Cord plug connections:

Cable Pin International

Brown
Light blue
Yellow/Green| Live
Neutral
Earth| L
N

This device falls under protection class I.Therefore the ArcPower 72 has to be connected to a mains socket outlet with a protective earthing connection.
4.2.Mounting the ArcPower 72
The ArcPower 72 should be be placed on a non-flammable f lat surface in any orientation and fixed by the two screws.There are two mounting holes of diameter 5 mm in housing of the driver. Ensure that instalation place is enough ventilated.

Anolis ArcPower 72 LED Lighting - DyNet protocol 1

4.3.Conection cables

  1. The adapter cable RJ45/XLR connects the ArcPower 72 to the DMX controller.If your DMX controller has RJ45 socket for DMX output,use RJ45 patch cable for connection with the ArcPower 72.cAnolis ArcPower 72 LED Lighting - DyNet protocol 1
  2. RJ45 patch cables category 5 that connect the ArcPower 72 each other are wired 1:1,that is,pins with the same numbers are connected together.

Installing instructions.

5.1.DMX operating

  1. Unplug from the mains before installation.
  2. Connect the LED modules to the fixture.
  3. Connect the DMX controller to the fixture
  4. Connect the fixture to the mains
  5. Set the DMX address on the control board of the fixture (see chapter “Control board”).

Warning!
Accidental connection DMX 512 Input/Output to non-DMX 512 device (e.g.Ethernet network Hub) can damage the ArcPower 72.
Maximum total cable length between one LED zone output of the Arcpower 72 and all its connected LED modules is 80 metres.

Single ArcPower 72 installation:

Anolis ArcPower 72 LED Lighting - ArcPower 6

Multiple ArcPower 72 installation:
Connect the DMX output of the first ArcPower 72 with the DMX input of the next ArcPower 72. Always connect one output with the input of the next ArcPower 72 until all fixtures are connected.In this way,up to 32 fixtures can be chained together.
At the last ArcPower 72 the data link has to be terminated with a terminator. A termination plug is simply a RJ45 connector with a 120 Ω resistor between pins Data (–) and Data (+).Plug terminator in the DMX output of the last ArcPower 72.
Maximum number of LEDs connected to the one zone of the ArcPower 72 is 36 in RGB mode and 42 in RGBW mode.
Maximum possible number of LED modules connected to the one zone of the ArcPower 72:

Anolis ArcPower 72 LED Lighting - ArcPower 6

Model

| total LEDs| Red LEDs| Green LEDs| Blue LEDs| White LEDs| Max.number of connected modules
---|---|---|---|---|---|---
ArcLine 12 RGB| 12| 4| 4| 4| –| 3
ArcLine 24 RGB| 24| 8| 8| 8| –| 1
ArcLine 36 RGB| 36| 12| 12| 12| –| 1
ArcLine Optic 12 RGB| 12| 4| 4| 4| –| 3
ArcLine Optic 24 RGB| 24| 8| 8| 8| –| 1
ArcLine Optic 36 RGB| 36| 12| 12| 12| –| 1
ArcSource 3 RGB| 3| 1| 1| 1| –| 12
ArcSource 6 RGB| 6| 2| 2| 2| –| 6
ArcSource 12 RGB| 12| 4| 4| 4| –| 3
ArcSource 7 RGBW| 7| 2| 2| 2| 1| 6

Note: You cannot combine RGB and RGBW modules (e.g. ArcSource 6 RGB and ArcSource 7 RGBW) each other as white LEDs will not light.

5.2.Master-slave operating

  1. Unplug from the mains before installation.
  2. Connect the LED modules to the fixtures.
  3. Connect the DMX output of the master fixture in the data-chain with the DMX input of the first slave. Always connect output with the input of the next slave until all slaves are connected.Up to 32 fixtures can be connected in master/slave chain
  4. Insert the termination plug (with 120 Ohm) into DMX input of the master fixture and into the DMX output of the last slave fixture in the link in order to ensure proper transmission on the data link.
  5. Connect the fixtures to the mains.
  6. See chapter “Stand-alone mode” in order to set the fixture as a master or slave.

Anolis ArcPower 72 LED Lighting - ArcPower 6

5.3. Operating via DyNet protocol

  1. Unplug from the mains before installation.

  2. Connect LED modules to the fixtures.
    Connect first fixture to the control panel which suports DyNet protocol (e.g. DLP 8100)

  3. Connect the DMX output of the first fixture in a data link with the DMX input of the second fixture. Always connect output with the input of the next fixture until all fixtures are connected.Up to 32 fixtures can be connected in data chain.

  4. Insert the termination plug (with  120 O hm) into DMX  output of the last fixture in order to  ensure proper transmission on the data link.

  5. Connect fixtures to the mains

  6. Select the DyNet protocol on all fixtures (menu SPE”—> Prt—> “dYn”).

Anolis ArcPower 72 LED Lighting - DyNet protocol 1

A description of each byte in DyNet protocol is the following:

Byte 0: 1C – hexadecimal Logical Message (fixed value)
Byte 1: 01 – Area
Byte 2: 00 – Channel level
Byte 3: 80 – Channel
Byte 4: ff – Channel Offset
Byte 5: 00 – Fade Rate
Byte 6: FF (fixed value)
Byte 7: 1C Checksum
Area – (0 to 255), as set on the Arcpower to give a unique address for each Arcpower unit (i.e. DMX base address)
Channel Level – (0 to 255), level – 01=100%, FF=0%
Channel – (80 to 83), 80= channel 1, 81= channel 2, 82= channel 3, 83= channel 4, (see Channel Offset if more than 4 channels)
Channel Offset – (0-255), default (FF)- channel offset in blocks of 4: (FF = CH 1-4, 00 = CH 5-8,
01 = CH 9-12, etc up to 3E = CH 253-256 )
Fade Rate – (0-255), fade rate with 1 second resolution (0= 0 seconds, 255= 255 seconds)
Checksum – (0-255), checksum Byte – used to ensure the integrity of the packet.
Negative two’s compliment of the preceding 7 bytes.

Example 1:
0x1C,0x10,0x00,0x80,0xff,0x05,0xff,0x52
This would control channel 1 (i.e. Red) of Arc power unit, address 16 to a Level of 100% with a fade of 5 seconds.
Example 2:
0x1C,0x05,0xCC,0x82,0xff,0x0A,0xff,0x52
This would control channel 3 (i.e. Blue) of Arc power unit, address 5 to a level of 20% with a fade of 10 seconds.

ArcPower 72 – Control menu map

Default settings=Bold print

Anolis ArcPower 72 LED Lighting - DyNet protocol 1

ArcPower 72-DMX protocol

Version 2.1 (software version 5.1 and higher)

Mode/Channel Value Function Type of control
1 2 3 4

ZONE 1
1| 1| 1| 1| 1| 0-255| Red LED 1
Red LED saturation control (0-100%)| proportional
2| 2| 2| 2| 2| 0-255| Green LED 1
Green LED saturation control (0-100%)| proportional
3| 3| 3| 3| 3| 0-255| Blue LED 1
Blue LED saturation control (0-100%)| proportional
–| 4| 4| –| 4| 0-255| White LED 1
White LED saturation control (0-100%)| proportional
ZONE 2
4| 5| 5| 1| 1| 0-255| Red LED 2
Red LED saturation control (0-100%)| proportional
5| 6| 6| 2| 2| 0-255| Green LED 2
Green LED saturation control (0-100%)| proportional
6| 7| 7| 3| 3| 0-255| Blue LED 2
Blue LED saturation control (0-100%)| proportional
–| 8| 8| –| 4| 0-255| White LED 2
White LED saturation control (0-100%)| proportional
Common channels for all Zones

|

|

9

|

|

| 0-7
8-15
16-23
24-31
32-39
40-47
48-55
56-63
64-71
72-79| Macro selection No function Macro 1
Macro 2
Macro 3
Macro 4
Macro 5
Macro 6
Macro 7
Macro 8
Macro 9
Macro 10
Macro 11
Macro 12
Macro 13
Macro 14
Macro 15
Macro 16
Macro 17
Macro 18
Macro 19
Macro 20
Macro 21
Macro 22
Macro 23
Macro 24
Macro 25
Macro 26
Macro 27
Macro 28
Macro 29
Macro 30
Rainbow effect with variable speed|

step step step step step step step step step step step step step step step step step step step step step step step step step step step step step step step proportional

|

|

10

|

|

|

0-31
32-63
64-95
96-127
128-143
144-159
160-191
192-223
224-255

| Shutter/Strobe Shutter closed Shutter open Strobe-effect from slow to fast Shutter open Opening pulses in sequences from slow to fast Closing pulses in sequences from fast to slow Shutter open Random strobe-effects from slow to fast Shutter open|

step step proportional step proportional proportional step proportional step

–| –| 11| 4| –| 0-255| Dimmer Dimmer intensity from 0% to 100%| proportional

Control board

The control panel situated on the top cover of the ArcPower 72 allows DMX addressing,calling Built-in programs and setting the fixture behaviour

Control elements:
[ENTER] button- enters menu,confirms adjusted values and leaves menu.
, [UP] button and[DOWN] button- moves between menu items on the the same level, sets values.
In order to leave the menu without saving value,press [UP] and [DOWN ] at the same time.
After switching on the ArcPower 72 ,the display shows the initial DMX address:

Use [UP],[DOWN] to browse through the menu. To select a function or submenu,press [ENTER].
8.1 Addressing the ArcPower 72

The fixture can be operated in the two modes: DMX mode-fixture is controlled via DMX 512 by an external
DMX controller
Stand-alone mode – fixture uses Built-in programs and is able to control other fixtures in the master/slave chain. See the chapter “Stand-alone mode” for detail description.

 For DMX mode, it is important to define the starting DMX address from which the ArcPower 72 will respond to the DMX controller
Setting the DMX start channel for DMX operating:

  1. Connect ArcPower 72 to the mains.
  2. Browse through the menu by pressing the [UP] and [DOWN] buttons until the display shows current addres “001”.Confirm by pressing [ENTER] button and “001” will start to flash frequently.
  3. Use the [UP] and [Down] buttons to select the desired address.
  4. Confirm by pressing [ENTER].
    After having addressed ArcPower 72, you may now start operating ArcPower 72 via your DMX controller.

8.2 Program running

By entering this menu a complete overview of all programs is offered,from which the program to be run can be selected by pressing [ENTER].Selected program runs in a loop.The fixture includes 6 built-in programs (P.01-P.6) and 3 free editable programs (E.P.1-E.P.3),each up to 30 steps. If item “AUt” is On,the fixture in DMX mode will remember last running program and this program will run after switching on the fixture.
Each program step has a fade time – the time during which effects go to the current step and a Standing time-the time,during which effects last in the current step.

current step

Anolis ArcPower 72 LED Lighting - ArcPower 6

Programming procedure:

  1. Enter “EdI.” menu
  2. Press [UP] or [DOWN] to select the desired program which you wish to edit and press [ENTER].
  3. Press [UP] or [DOWN] to select the desired program step (“S.01” – “S.30”) and press [ENTER].
  4. Press [UP] or [DOWN] to select the desired item and press [ENTER]-button.Now you can edit by using [UP] or [DOWN] buttons the DMX values selected item (the list of items depends on selected DMX mode):
    End. – a total number of the program steps (value 1-30).This value you must set before start programming(e.g. if you want to create program with 10 steps,set End=10).

rE1 – a red LED 1 saturation, value 0-255
Gr1 – a green LED 1 saturation, value 0-255
bL1 – a blue LED 1 saturation, value 0-255
Wh1 – a white LED 1 saturation, value 0-255
rE2 – a red LED 2 saturation, value 0-255
Gr2 – a green LED 2 saturation, value 0-255
bL2 – a blue LED 2 saturation, value 0-255
Wh2 – a white LED 2 saturation, value 0-255

Following item are common for all zones:
MAC. – a macro selection,value 0-255
Str. – a strobe,value 0-255
dim. – a dimmer,value 0-255
FA.t. – fade time,value 0-255
S.tI. – standing time,value 0-255

COP. – copying the current prog. step to the next prog. step.
Press [ENTER]-button to confirm adjusted value.
5. Repeat steps 3 and 4 for next prog. step. If you want to copy current program step to the next prog. step, select option „COP.” and confirm it by pressing [ENTER].
*Both Fade time and Standing time use the same conversion table in order to convert DMX value to the time value:

DMX| Time [sec.]| DMX| Time [min.]| DMX| Time [min.]| DMX| Time [min.]| DMX| Time [min.]
---|---|---|---|---|---|---|---|---|---
1| 0.1| 50| 4.2| 105| 18.4| 160| 42.7| 215| 77
2| 0.4| 55| 5| 110| 20.2| 165| 45.4| 220| 80.7
5| 2.5| 60| 6| 115| 22| 170| 48.2| 225| 84.4
10| 10| 65| 7| 120| 24| 175| 51| 230| 88.2
15| 22.5| 70| 8.2| 125| 26| 180| 54| 235| 92
20| 40| 75| 9.4| 130| 28.2| 185| 57| 240| 96
25| 62.5| 80| 10.7| 135| 30.4| 190| 60.2| 245| 100
30| 90| 85| 12| 140| 32.7| 195| 63.4| 250| 104
35| 122.5| 90| 13.5| 145| 35| 200| 66.7| 255| 108
40| 160| 95| 15| 150| 37.5| 205| 70| |
45| 202.5| 100| 16.7| 155| 40| 210| 73.5| |

Exact expression of the time value follows the formula: time[sec.]=(DMX value)²/10.

8.3 Manual mode

This menu gives access to the control of the fixture channels by means of the control buttons. Use [UP] and [DOWN] buttons until the display shows “MAn.” menu.Press [ENTER] button and by using [UP] and [DOWN] buttons select desired effect,press [ENTER] and and by using [UP] and [DOWN] buttons adjust desired DMX value for selected effect.Confirm by [ENTER].

rE1 – a red LED 1 saturation, value 0-255
Gr1 – a green LED 1 saturation, value 0-255
bL1 – a blue LED 1 saturation, value 0-255
Wh1 – a white LED 1 saturation, value 0-255
rE2 – a red LED 2 saturation, value 0-255
Gr2 – a green LED 2 saturation, value 0-255
bL2 – a blue LED 2 saturation, value 0-255
Wh2 – a white LED 2 saturation, value 0-255
MAC. – a macro selection, value 0-255
Str. – a strobe, value 0-255
dim. – a dimmer, value 0-255
The list of items depends on the DMX mode that has been choosen,.

8.4 Test sequences


Use the item to run a special demo-test sequences without an external controller,which will show you some possibilities of using the fixture.
8.5 Stand-alone mode

Select this menu to set fixture behaviour in stand-alone mode without an external controller.
Synchronous operation of multiple fixtures requires that they must be connected on a data link and one of them is set as a master (“MSt”) and the rest as the slaves (“SLA”).Only one fixture can be set as the master.The slaves mimic the behavior of the master.Effect actions are triggered by an internal timer of the master fixture. Important!: Disconect the fixtures from the DMX controller before master/slave operating ,otherwise data collisions can occur and the fixtures will not work properly!
MSt. — Master.Enter this menu if you want to set the the fixture as a master.Use [UP] and [DOWN] buttons to select desired program and press [ENTER] to confirm selection.
SLA. — Slave.Enter this menu if you want to set the the fixture as a slave.
The master fixture starts simultaneous program start in the other slave fixtures.All fixtures are synchronized in every prog.steps.The fixtures run their programs repeatedly (e.g. if master runs its program “P05”,all slaves will be executed program also “P05”).
Note: If the master runs its editable program (EP1,EP2 or EP3),all slaves will execute their own editable programs
(EP1,EP2 or EP3) according the master,but  bothfade  time(FA.t.) and standing time (S.tI.) for each step will be taken from the master´s step (slaves´ times are eliminated in  ach step).

8.6 Special functions

Use this menu for special services.
VEr. — Software Version.Select this function to read the number of the fixture software.
bAL. — Balance.Select this function to enable (On) or disable (OFF) the white balance which is set in “White colour balance” menu below.If this function is set  FF,ArcPower 72 will use maximum value (255) of saturation for red, green and blue channel.
C.bA. — White colour balance. Using this menu you can set white balance:
1. Browse through the menu by pressing the [UP] and [DOWN] buttons until the display shows “C.bA.” menu.
Press [ENTER] button and “rE.b.” will appear on the display.
2.Press [ENTER] button again and use [UP] and [DOWN] buttons to adjust the new maximum value required for the red channel.Confirm your choice by pressing [ENTER].Use the [UP] and [Down] buttons to select next colour. 3.Repeat step 2 for green channel “Gr.b.” and for blue channel “bL.b”.
Zon. — Zone selecting.Zon. The option enables select desired number of the zone (from 0 to 8).
The number of the zone distinguishes individual zones of the ArcPower 72 which is controled via RS-232 interface.
Use [UP] and [DOWN] buttons to select desired zone and press [ENTER] to confirm selection. The selected zone number is assigned to the first LED output and the second one has its zone number by one number higher.

Anolis ArcPower 72 LED Lighting - DyNet protocol 3

d.MP. — DMX presetting.The function makes possible to select from 5 DMX modes.Use [UP] and [DOWN] buttons to select desired channel mode(“Mo.1-5″) and press [ENTER] to confirm selection. i.bL. — Initial blink.If this function is on,ArcPower 72 makes auto-calibration (All LEDs light on 100% for short time) after switching it on.If this function is set off,you have to set manually every colour on max.brightness after switching on the driver before starting regular operating.This action should last min. one second.In this moment, the ArcPower 72 finds out the load connected to its LED output and makes auto- calibration. Prt — Protocol selection – Selects a required communication protocol. dMH – the fixture will communicate using DMX 512 signal. dYn – the fixture will communicate using the DyNet protocol. C.Li. — Current limiting.The menu item allows to reduce a current-carrying capacity of each LED branch (colour) in order to keep a declared lifetime of LED modules.The situation can occur if you operate LED modules at an higher ambient temperature than is recommended (40°C). The current-carrying capacity can be changed in a range of 350 – 175 mA (255-128) linearly.A default value is 255 (350 mA). To adjust the current limiting:

  1. Browse through the menu by pressing the [UP] and [DOWN] buttons until the display shows “C.Li.” menu. Press [ENTER] button and “rE1” item will appear on the display.
  2. Press [ENTER] button again and use [UP] and [DOWN] buttons to select desired value. Confirm this value by pressing [ENTER].Use the [UP] and [Down] buttons to select next colour.
  3. Repeat step 2 for items “Gr1”, “bL1”, “Wh1″,”rE2″, Gr2”, “bL2” and “Wh2”.

UPd. — Software update – Using this function you can update software in the fixture via PC and serial link.
The following items are required in order to update software:
– PC running Windows or Linux or macOS
– DSU file
– Flash cable RS232/DMX, P/N13050624 (if you want to use a serial port of PC)
– Robe Universal Interface or Robe Universal interface WTX (if you want to use an USB port of PC)
After the software updating the fixture will be set to default (factory) values.

To update software in the fixture:

  1. DSU file is available from Robe web site at WWW.robe.cz.
    File with extension zip is intended for Windows (used and tested from XP to W10 on 32/64bit systems).
    File with extension tbz is intended for Linux (used and tested on Debian and Ubuntu 32/64bit).
    File with extension dmg is intended for macOS (used and tested on OSX up to Sierra) XQuartz required,
    install it from https://www.xquartz.org/
    Save the download file to a folder on your computer.
    In case that you use windows, extract files in the zip file (e.g. DSU_ArcPower72_13120449.zip)

  2. Disconnect the fixture from DMX controller.

  3. If you use the flash cable RS232/DMX, connect a serial port of your computer with DMX input of the fixture by means of the cable.
    If you use the Robe Universal Interface, connect a USB port of your computer with the Robe Universal Interface by means of the USB cable and DMX input of the fixture with the DMX output of the Robe Universal Interface via a DMX cable.

  4. Switch the fixture to the update mode (SPE–>UPd–>yES).
    Note: If you do not want to continue in the software update, you have to switch off and on the fixture to escape from the updating mode.
    We recommend to cancel all running programs on your computer before starting the software update.

  5.  Double-click the software uploader file (e.g. DSU_ArcPower72_13120449.exe) in the extracted files. The Software Uploader program will start running.

  6. Select correct “COM ” number if you use a Flash cable RS232/DMX or select “Robe Universal Interface ” if you use the Robe Universal Interface/Robe Universal Interface WTX and then click on the “Connect” button.

  7. If the connection is OK, click the “Start Uploading” button to start software uploading. It will take several minutes to perform software update.
    If the option “Incremental Update” is not checked, all processors will be updated (including processors with the same software version).
    If you wish to update only processors with new version of software, check the “Incremental Update box“.

Avoid interrupting the process. Update status is being displayed in the “Info Box” window.
When the update is finished, the line with the text “Fixture is successfully updated“ will appear in this window.
In case upload process is interrupted (e.g. power loss), the fixture stays in “Updating mode” and you will have to repeat the software update again.
Another way, how to update software in the fixtures (especially large installation of fixtures) is to use the ROBE Uploader. It is a software for automatized software update of Robe fixtures. It takes advantage of RDM support).
For more information please see https://www.robe.cz/robe-uploader/.

Control of the ArcPower 72 via RS-232

9.1 Wiring an RS-232 serial port

9-pin D connector (male)
Front view of the socket:

Anolis ArcPower 72 LED Lighting - DyNet protocol 1

RS-232 cable:


Anolis ArcPower 72 LED Lighting - DyNet protocol 1The maximum cable length according to the standard is 15 metres or the cable length equals to a capacitance of 2500 pF.

9.2 Selecting a zone
The number of the zone distinguishes individual drivers which are controled via RS-232 interface.
Select SPE in main menu of the ArPower 72, press [ENTER],use [UP] and [DOWN] buttons to select Zon.
The option enables to select desired number of the zone (from 0 to 8).Press [ENTER],use [UP] and [DOWN] buttons to select zone number and press [ENTER] to confirm selection.

9.3 Setting a serial port of PC
The serial port of your personal computer hould be configured as follows:
9600 Baud,8 Data Bits,Non Parity,One Stop Bit,No Flow Control Required.
9.4 Zone commands
The ArcPower 72 uses the 3 types of the zone commands which can be used in a suitable software running on PC.
All zone commands stated below have to be send to the ArcPower 72 in ASCII codes.
Type 1: Selection of the preset colours
The syntax of the command is:
zone Z red;
zone Z green;
zone Z blue;
zone Z white;
zone Z yellow;
zone Z cyan;
zone Z magenta;
zone Z blackout;

Z ………..means number of the zone (0-9)
red/green/blue/white/yellow/cyan/magenta….determines colour
blackout…….closes light output ;………….means end of character sequence
Examples: zone 3 green;
zone 0 blackout;

Type 2: Colour mixing-RGB
The syntax of the command is:

zone Z r,g,b;
Z………… means number of zone (0-9)
r ………….means DMX value of the red colour(0-255)
g …………means DMX value of the green colour (0-255)
b …………means DMX value of the blue colour (0-255)
; ………….means end of character sequence
, …………..values of colours have to be separated by a comma.
Examples: zone 0 234,126,165;
zone 1 5,18,28;
Type 3: Colour mixing-RGBW
The syntax of the command is:
zone Z r,g,b,w;
Z………… means number of zone (0-9)
r ………….means DMX value of the red colour(0-255)
g …………means DMX value of the green colour (0-255)
b …………means DMX value of the blue colour (0-255)
w …………means DMX value of the white colour (0-255)
; ………….means end of character sequence
, …………..values of colours have to be separated by a comma.
Examples: zone 0 156,145,171,211;
zone 1 5,18,28,148;

Technical Specifications

Power supply:
Input Voltage: 100-240 V AC, 50/60 Hz
Fuse:T 2 A
Max.Pover Consumption:120VA
Input:
Control:DMX 512 or DyNet protocol
DMX connection:RJ45
RS 232 connection:9-pin D connector
Output:
Max.Output Voltage:48V DC
Max.Output current:350mA per colour
Max.load per zone : 36 LED´s in RGB mode, 42 LED´s in RGBW mode
Total load :72 LED´s in RGB mode
84 LED´s in RGBW mode

Maximum total cable length between one LED zone output and all its connected LED modules:
80 metres at max. load .
DMX channels:
Mode 1: 6 channels
Mode 2: 8 channels
Mode 3: 11 channels
Mode 4: 4 channels
Mode 4″ 4 channels
Control and programming:
Protocol: USITT DMX-512
Two DMX protocol modes for RGB light sources
Two DMX protocol modes for RGBW light sources
Control options:DMX,Auto-trigger
Operation modes:Master/Slave,Stand alone
Programs:6 Built-in programs+3 user editable programs up to 30 steps each
Display:3 digit LED
White colour balance adjusting
Manual control of all DMX channels with LED control panel
Operating temperature:
-10°C/+40°C
Dimensions(mm):

Anolis ArcPower 72 LED Lighting - DyNet protocol 1

Weight:
1.8kg
Accessories:
Cable joiner (No.13050691)……………2 pcs
Optional accessories:
Adaptor RJ45/DMX 3 pin…….No.13050730
Adaptor RJ45/DMX 5 pin…….No.13050731

Replacing the fuse

  1. Before replacing the fuse, unplug mains lead!
  2. Unscrew the fuse holder on the rear side of the ArcPower 72 with a fitting screwdriver from the housing (anti-clockwise).
  3. Remove the old fuse from the fuse holder.
  4. Install the new fuse in the fuse holder.
  5. Replace the fuse holder in the housing and fix it.

QR code for user manual

https://www.anolislighting.com/resource/arcpower-72-user-manual
May 24, 2022
All Specifications subject to change without notice
Made in CZECH REPUBLIC by ROBE LIGHTING s.r.o. Palackeho 416/20 CZ 75701 Valasske Mezirici
version 2.0