Anolis 3.3 Eminere LED Lighting User Manual
- June 1, 2024
- ANOLiS
Table of Contents
- 3.3 Eminere LED Lighting
- QR code for user manual
- 1. Safety instructions
- 2. Fixture exterior view
- 3. Installation
- 3.2 C-clamps installation
- 3.3 Connection to mains
- E-box Daisy
- E-box Star
- E-box Pro
- E-box Lite
- 3.4 The Booster box
- 3.5 The Booster box installation
- Power connection
- Cable gland M20 MS:
- 3.6 Jumper cable assembling
- 3.7 Example of Control panel in RDM manager
- Manufacturer PIDs
- 4. Software update
- DMX or Ethernet connection via E-box
- 5. Technical specifications
- Optic
- Compatible drivers
- Sizes
- Housing
- Cooling system
- Total heat dissipation
- Protection factor
- Impact rating
- Operating ambient temperature range
- Operating temperature
- Connection
- Weight
- Dimensions (All dimensions in mm [inch])
- Included items
- Optional accessories
- US Leader Cables FF:
- Jumper Cables FF/FM:
- E-boxes:
- 6. Cleaning and maintenance
- 6.1 Disposing of the product
- 7. ChangeLog
- DMX protocol
- DMX protocol
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
3.3 Eminere LED Lighting
QR code for user manual
Version 3.3
Eminere
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY
BEFORE POWERING OR INSTALLING YOUR Eminere !
Save it for future reference.
This device has left our premises in absolutely perfect condition. In order to maintain this condition and to ensure safe operation, it is absolutely necessary for the user to follow the safety instructions and warnings written in this manual.
The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unauthorized modification to the device.
Unauthorized modification will void warranty.
1. Safety instructions
DANGEROUS VOLTAGE CONSTITUTING A RISK OF ELECTRIC SHOCK IS PRESENT WITHIN THIS UNIT!
This fixture should be operated only from the type of power source indicated on the marking label. If you are not sure of the type of power supplied, consult your authorized distributor or local power company.
Always disconnect the fixture from AC power before cleaning, servicing or installing.
Make sure the data/power cable is not damaged by sharp edges. Check the fixture and the power cord from time to time.
Do not install the unit near an open flame.
During operation the housing becomes hot.
Refer servicing to qualified service personnel.
This fixture falls under protection class I . Therefore this fixture has to be connected to a mains socket outlet with a protective earthing connection.
Do not connect this fixture to a dimmer pack.
LED light emission. Risk of eye injury. Do not look into the beam from a short distance without suitable protective eyewear. Do not look at LEDs with magnifiers or similar optical instruments that may concentrate the light output.
The fixture was designed for outdoor use. This fixture must not be used for underwater installation. When choosing the installation spot, please make sure that the fixture is not exposed to extreme heat or dust. Avoid using the unit in locations subject to possible impacts.
The fixture body never must be covered with cloth or other materials when the fixture is under operation. Only operate the fixture after having checked that the housing is firmly closed and all screws are tightly fastened.
Eminere
The fixture becomes hot during operation. Allow the fixture to cool approximately 30 minutes prior to servicing or maintenance.
Operate the fixture only after having familiarized yourself with its functions. Do not permit operation by persons not qualified to operate the fixture. Most damages are the result of unprofessional operation!
Please consider that unauthorized modifications on the fixture are forbidden due to safety reasons! Please use the original packaging if the fixture is to be transported.
If this device will be operated in any way different to the one described in this manual, the product may suffer damages and the warranty becomes void. Furthermore, any other operation may lead to dangers like short-circuit, burns, electric shock etc.
The product (covers and cables) must not be exposed to a high frequency electromagnetic field higher than 3V/m.
Immunity of the equipment is designed according to the standard EN 55035 Electromagnetic compatibility of multimedia equipment – Immunity requirements
Emission of the equipment complies with the standard EN55032 Electromagnetic compatibility of multimedia equipment – Emission Requirements according to class B.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
The [Device] wireless operation is safe and complies to RF Exposure requirements.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
– Reorient or relocate the receiving antenna.
– Increase the separation between the equipment and receiver.
– Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
– Consult the dealer or an experienced radio/TV technician for help.
Warning for fixtures with Harsh Environment Finish (HEF):
Handle with care!
Avoid any damage to the painted surface.
Damaging the paint may result in corrosion and loss of warranty.
Eminere
2. Fixture exterior view
- Transparent glass cover
- LED module
- Output connector
- Input connector
- Mounting brackets
- Aluminum base
3. Installation
3.1 Mounting the fixture
The Eminere can be arranged in any orientation on a flat, non-flammable surface by means of two mounting brackets (5), the LED module (2) can be tilted (+95°/-95°) to get access to mounting brackets (5).
Ensure that the structure to which you are attaching the unit is secure.
Eminere
3.2 C-clamps installation
- Remove the mounting bracket (5) from fixture housing by unscrewing two screws (6).
- Screw the new mounting bracket (9) to the fixture housing by means of two screws (6).
- Screw the clamp (7) to the mounting bracket by means of the bolt M12x30 (10) with nuts M12 (8).
Eminere
3.3 Connection to mains
The unit must be installed by a qualified electrician in accordance with all national
and local electrical and construction codes and regulations.
This device falls under class one and must be grounded!
The Eminere is equipped with auto-switching power supply that automatically adjusts to any 50/60Hz AC power source from 120-277 Volts.
The following wiring of the input/output connectors applies to the fixtures marked X on their labels only. Older versions of the Emineres have swapped D- and D+ and do not have mark X on their labels. E.g.
Input – panel connector Output – panel connector
(front view) (front view)
Fixture´s Amphenol connectors are dust and water protected according to IP 67 by mating with related Amphenol connectors.
They cannot stay disconnected outdoor.
The output panel connector at last fixture in the Eminere chain has to always be covered with the water-tight cap to keep declared IP rating.
The Eminere modules should be connected to the E-box which allows power supply of the Eminere modules and their control.
Do not connect (disconnect) Emineres to the E-box or Booster box and each other when they are under voltage!
When you change any setting of the E-box, disconnect the E-box from power and connect it to power again to activate changes which you have made.
Examples of connection for various versions of the E-box.
Please read the E-box user manual for more information about its setting and connection to Eminere modules. Needed cables are stated in the chapter “Technical information“.
E-box Daisy
7
E-box Star
Eminere
E-box Pro
8
E-box Lite
Eminere
Number of connected Emineres to one E-box output depends on a cable length, power voltage, type of Eminere and E-box and operation mode.
The tables below state max. theoretical number of Emineres connected to the one LED output of the E-box without Booster boxes. The following tables apply for the Standard mode of E-boxes.
EMINERE 1 Voltage
Cable length * 120V 190V 230V 277V
10 m 83 131 159 191
20 m 83 131 159 191
30 m 58 131 159 191
50 m 35 88 128 186
70 m 25 63 92 133
100 m 17 44 64 93
200 m
|
9
|
22
|
32
|
47
---|---|---|---|---
EMINERE 2 Voltage
Cable length * 120V 190V 230V 277V
10 m 41 64 78 94
20 m 41 64 78 94
30 m 28 64 78 94
50 m 17 43 63 91
70 m 12 31 45 65
100 m 9 21 31 46
200 m
|
4
|
11
|
16
|
23
---|---|---|---|---
Eminere
EMINERE 3 Voltage
Cable length * 120V 190V 230V 277V
10 m 28 44 53 64
20 m 28 44 53 64
30 m 19 44 53 64
50 m 12 29 43 62
70 m 8 21 31 44
100 m 6 15 21 31
200 m
|
3
|
7
|
11
|
16
---|---|---|---|---
EMINERE 4 Voltage
Cable length * 120V 190V 230V 277V
10 m 21 33 40 48
20 m 21 33 40 48
30 m 15 33 40 48
50 m 9 22 32 47
70 m 6 16 23 38
100 m 4 11 16 23
200 m
|
2
|
5
|
8
|
12
---|---|---|---|---
- Cable length is a total cable length between E-box and last connected Eminere.
Example: Total cable length=L1+L2+L3
Notice for the E-box Star: The tables above state max. total number of Emineres connected to 6 LED outputs of the E-box Star (or max. number of Emineres connected to one output if the rest of outputs is not connected).The E-box Star has only one power input!
3.4 The Booster box
To compensate a voltage drop in large installation, the Booster boxes have to be connected in the chain of Emineres at every LED output of the E-box.
The following tables give numbers of Emineres after which the Booster box has to be installed in the chain of Emineres (at one LED output of the E-box). The following tables apply for the Standard mode of E-boxes.
Eminere
EMINERE 1 Max. number of Emineres 1= 191 Voltage
Cable length
120V 190V 230V 277V
10 m 83,166 131 159 – 20 m 83,166 131 159 – 30 m 58,116,174 131 159 – 50 m 35,70,105,140,175 88,176 128 186
70 m 25,50,75,100,125,150,175 63,126,189 92,184 133
100 m 17,34,51,68,85,102,119, 136,153,170,187
44,88,132,176 64,128 93,186
200 m
|
9,18,27,36,45,54,60,72,81 90,99,108,117,126,135,144 153,162,171,180,189,
|
22,44,66,88,110, 132,154,176
|
32,64,96,128, 160
|
47,94,141, 188
---|---|---|---|---
EMINERE 2 Max. number of Emineres 2= 94
Voltage
Cable length
120V 190V 230V 277V
10 m 41,82 64 78 – 20 m 41,82 64 78 – 30 m 28,56,84 64 78 – 50 m 17,34,51,68,85 43,86 63 91
70 m 12,24,36,48,60,72,84 31,62,93 45,90 65
100 m 9,18,27,36,45,54,60,72,81, 90
21,42,63,84 31,62,93 46,92
200 m
|
4,8,12,16,20,24,28,32,36 40,44,48,52,56,60,64,68,72 76,80,84,88,92
|
11,22,33,44,55, 66,77,88
|
16,32,48,64,80
|
23,46,69,92
---|---|---|---|---
EMINERE
3 Max. number of Emineres 3= 64
Voltage
Cable length
120V 190V 230V 277V
10 m 28,56 44 53 – 20 m 28,56 44 53 – 30 m 19,38,57 44 53 –
50 m 12,24,36,48,60 29,58 43 62
70 m
|
8,16,24,32,40,48,56
|
21,42,63
|
31.62
|
44
---|---|---|---|---
Eminere
100 m 6,12,18,24,30,36,42,48,54, 60
15,30,45,60 21,42,63 31,62
200 m
|
3,6,9,12,15,18,21,24,27,30, 33,36,39,42,45,48,51,54,57 60,63
|
7,14,21,28,35,42 49,56,63
|
11,22,33,44,55
|
16,32,48,
---|---|---|---|---
EMINERE 4 Max. number of Emineres 4= 48
Voltage
Cable length
120V 190V 230V 277V
10 m 21,42 33 40 – 20 m 21,42 33 40 – 30 m 15,30,45 33 40 – 50 m 9,18,27,36,45 22,44 32 47
70 m 6,12,18,24,30,36,42 16,32 23,46 38
100 m 4,8,12,16,20,24,28,32,36, 40,44
11,22,33,44 16,32 23,46
200 m
|
2,4,6,8,10,12,14,16,18,20, 22.24.26,28,30,32,34,36,38 40,42,44,46
|
5,10,15,20,25,30 35,40,45
|
8,16,24,32,40
|
12,24,36
---|---|---|---|---
Example: E-box Daisy, Power supply= 230V, Cable length=70m, fixture=Eminere 2
The Booster box has to be connected after every 45th Eminere 2 (fixture 45 and fixture 90) from 94 fixtures.
Eminere
3.5 The Booster box installation
ALWAYS DISCONNECT THE EMINERES FROM MAINS BEFORE CONNECTING/DISCONNECTING THE BOOSTER BOX.
The Booster box falls under protection class I. Therefore, every Booster box
has to be connected to a mains socket outlet with a protective earthing connection.
1.Unscrew the four screws (1) from the cover (2) on the Booster box to get access to the terminal block (3) and two mounting holes of diameter of 4.6 mm (4).
2. Screw the Booster box on a non-flammable flat surface and connect cables.
The Cable gland M20x1.5 for Power IN (5) is intended for a cable of a diameter of 7-13mm. Remove the end cap from the cable gland before passing the cable.
Power connection
L N (earth)
Core (EU) Braun Blue Green/yellow
Core (US)
|
Black
|
White
|
Green
---|---|---|---
We recommend to apply an adequate layer of the paste LOCTITE 5331 on the plastic holder of the cable gland before inserting it into the body of the gland and an adequate layer of the paste LOCTITE 577 on the thread of the gland body.
Eminere
Cable gland M20 MS:
The cable gland M20 MS with a standard seal serves for a cable of diameter of 7-13mm, for smaller diameter of cable (4-8mm) you have to remove the original seal from the cable gland M20 and use the enclosed reducing seal instead of it. The reducing seal for diameter of cable 4-8mm (P/N 13051388) is enclosed in the Booster box.
3. Screw the cover (2) back on the Booster box.
3.6 Jumper cable assembling
1. Dismantle the connector and slide its parts onto the cable (6).
Use the seal with inner diameter of 14.5 mm for the Anolis cable (P/N 13053138 or P/N 13053139). The seal with inner diameter of 14.5 mm serves for cable of diameter 10-14.5mm.
The seal with inner diameter of 10 mm serves for cable of diameter 8-10mm.
Parts of the connector
2. Put the seiling circle (2) on the connector with screws (1).
3. Remove insulation from the cable (6) and from individual wires and fasten three terminals on data wires.
3. Put parts of the connector on the cable (6) and connect wires to the connector. First connect power wires (L,N, Earth) and after that data wires (D+, D-, 0V). Avoid excessive torsion of data wires!
4. After connecting wires to the connector, tighten the three data wires (D+,D-, 0V) by means of the cable binder (7).
6. Screw the clamp ring (3) to the connector (1), insert the seal (4) to the clamp ring (3) and tighten the sealing nut (5) enough. During the steps DO NOT TWIST the cable (6).
7. Use the same procedure to assemble the connector on the second end of the cable.
IMPORTANT
Do not bend the cable near to the connector, minimum distance for bending is 50mm.
3.7 Example of Control panel in RDM manager
The software RDM manager is available on the ROBE website (https://www.robe.cz/support), product RUNIT WTX.
Manufacturer PIDs
Wireless unlink – the item allows you to unlink the Eminere from a DMX transmitter (Wireless DMX version of the Eminere only).
LED calibration 4byte HEX! (RGBW/RGBA) – the item shows 4 bytes of calibration values for calibrated white colours of RGBW(RGBA) Eminere.
E.g.
CTC channel has to be set to some calibrated white colour (21 DMX-1800K, 66 DMX-2700K, 91 DMX-3200K, 141 DMX-4200K, 211 DMX-5600K, 255 DMX-6500K) otherwise the item shows values “ff ff ff ff” (and calibration values cannot be saved to the Eminere).
Warning! ****
Changing and saving values in this item will effect calibrated white colour(s)
of the Eminere .
Insect friendly light – the item effects RGBA Eminere only. If the item is on, blue colour is not used in calibrated white colours. This modification of white lights results in a smaller attraction of white light for insects (mosquitos, moths..). The function is also available from DMX chart (channel Special Function, range 7-10 DMX).
Pixel Swap – the item allows you to swap the pixel order (for Eminere 2/3/4 only).
Terminator active – the item allows you to terminate line of Emineres at last Eminere.
4. Software update
Software update of Eminere has to be done by means of the software ROBE Uploader running on PC. The ROBE Uploader is a software for automatized software update of ROBE fixtures. The ROBE Uploader switches Emineres to the update mode automatically.
Please see https://www.robe.cz/robe-uploader/ for more information.
DMX or Ethernet connection via E-box
If the option Standard is selected from the menu E-box mode and LED modules are connected in series, the E-box will be updated including connected Eminere modules. You have to use the file EminereEbox.lib in the ROBE Uploader for this operating mode.
If the option Pass-Thr is selected from the menu E-box mode and LED modules are connected in series, you have to do the following steps to update Emineres including the E-box:
1. Set the E-box to the Standard mode and switch it off/on. Only E-box will be shown in the ROBE Uploader. You have to use the file EminereEbox.lib in the ROBE Uploader for software update of the E-box and connected LED modules.
2. After updating, set the E-box to the Pass-Thorough mode and switch it off/on. For more information about updating please see the E-box Lite/Daisy/Star user manual.
5. Technical specifications
Power supply
-
Electronic auto-ranging
-
Input voltage: 120 – 277V AC, 50/60 Hz
-
Power consumption:
Eminere 1: 25W
Eminere 2: 45W
Eminere 3: 65W
Eminere 4: 85W -
Inrush current:
Eminere 1: <70A/250µs
Eminere 2: <70A/250µs
Eminere 3: <100A/200µs
Eminere 4: <100A/200µs
Optic
-
Light source:
Eminere 1: 12 x high power LEDs
Eminere 2: 24 x high power LEDs
Eminere 3: 36 x high power LEDs
Eminere 4: 48 x high power LEDs -
Colour variants: RGBW, RGBA, single colour
-
Beam Angle:
Symetrical: 9°, 15°, 30°, 50°, 65°, 100°
Bi-symetrical: 10° x 30°, 30° x 10°, 10° x 60°, 60° x 10°, 35° x 70°, 70° x 35°, 15° x 90°, 90° x 15°
Wallwasher, Wide Wallwasher -
Projected Lumen Maintenance: L90B10 >90.000 hrs, Ta = 25°C / 77°F
Compatible drivers
-
E-box Daisy
1 Output
1 Main power Input
Control: DMX, Art-Net, sACN , W-DMX control, RDM
Pixel control (1px= 1ft)
120-277V Input
Connection via terminal blocks, inlets via grommet
IP67 -
E-box Star
6 outputs
1 Main power Input
Control: DMX, Art-Net, sACN , W-DMX control, RDM
Pixel control (1px= 1ft)
120-277V Input
Connection via terminal blocks, inlets via grommet
IP67 -
E-box Pro
6 outputs
6 Main power Inputs
Control: DMX, Art-Net, sACN , W-DMX control, RDM
Pixel control (1px= 1ft)
120-277V Input
Connection via terminal blocks, inlets via grommet
IP67 -
E-box Lite
1 output
1 Main power Input
Control: DMX, W-DMX control, RDM
Pixel control (1px= 1ft)
120-277V Input
Connection via screw terminal blocks, inlets via grommet
IP67
Mounting method -
Via two L-shape brackets
-
LED module “tilt” adjustment range: -95°/+95°
Sizes
- Eminere 1 (300mm / 1ft)
- Eminere 2 (600mm / 2ft)
- Eminere 3 (900mm / 3ft)
- Eminere 4 (1200mm / 4ft)
Housing
- Aluminium extruded body with die-casted end caps
- Tempered glass
Cooling system
- Convection
Total heat dissipation
- Eminere 1: 61 BTU/h (calculated)
- Eminere 2: 130 BTU/h (calculated)
- Eminere 3: 177 BTU/h (calculated)
- Eminere 4: 228 BTU/h (calculated)
Protection factor
- CE: IP 67
- US: Suitable for wet location
Impact rating
- CE: IK06
Operating ambient temperature range
- -20°C /+40°C (-4°F /+104°F)
Operating temperature
- +67°C @ Ambient +40°C (+153°F @ Ambient +104°F)
Connection
- Input: panel connector Amphenol ABAB-DMQ06000021-IN (P/N13052952)
- Output: panel connector Amphenol ABAB-DAQ06000021 (P/N13052953) + water-tight cap
Weight
- Eminere 1: 2.5 kg (5.5 lbs)
- Eminere 2: 4 kg (8.82 lbs)
- Eminere 3: 6.02 kg (13.27 lbs)
- Eminere 4: 7.7 kg (17 lbs)
Dimensions (All dimensions in mm [inch])
- C-Clamp
- Booster box
Included items
- 1 x Eminere
- 1 x User manual
Optional accessories
CE Leader Cables FF:
Leader Cable FF 2m (P/N 13053438)
Leader Cable FF 5m (P/N 13053440)
Leader Cable FF 10m (P/N 13053436)
Leader Cable FF 25m (P/N 13053437)
Leader Cable FF 50m (P/N 13053439)
US Leader Cables FF:
Leader Cable FF 2m (P/N 13053433)
Leader Cable FF 5m (P/N 13053435)
Leader Cable FF 10m (P/N 13053431)
Leader Cable FF 25m (P/N 13053432)
Leader Cable FF 50m (P/N 13053434)
Jumper Cables FF/FM:
Jumper Cable FF/FM 0.25m (P/N 13053422)
Jumper Cable FF/FM 0.5m (P/N 13053423)
Jumper Cable FF/FM 1m (P/N 13053425)
Jumper Cable FF/FM 2m (P/N 13053427)
Jumper Cable FF/FM 3m (P/N 13053428)
Jumper Cable FF/FM 5m (P/N 13053430)
Jumper Cable FF/FM 10m (P/N 13053424)
Terminal KE 106, diameter 0.14mm2 (P/N 13053403)
Waterproof Cover Cap FM ZAHB-0006 (P/N 17031173) Field Installable Connector FF (P/N 13053003)
Field Installable Connector FM (P/N 13053004)
C-clamp adaptors for Eminere (P/N 10980860)
E-boxes:
E-box Daisy (P/N 10063655)
E-box Daisy/W (P/N 10063638)
E-box Lite (P/N 10063657)
E-box Lite/W (P/N 10063653)
E-box Star (P/N 10063656)
E-box Star/W (P/N 10063644)
Booster box (P/N 10063712)
Shield for Eminere 1 RAL9011 (P/N 10980488)
Shield for Eminere 2 RAL9011 (P/N 10980489)
Shield for Eminere 3 RAL9011 (P/N 10980490)
Shield for Eminere 4 RAL9011 (P/N 10980491)
Cable Cover for Eminere 1 RAL9011 (P/N 10980484)
Cable Cover for Eminere 2 RAL9011 (P/N 10980485)
Cable Cover for Eminere 3 RAL9011 (P/N 10980486)
Cable Cover for Eminere 4 RAL9011 (P/N 10980487)
Mounting Brackets for Eminere 100mm, 2pcs RAL9011 (P/N 10980493) Mounting Brackets for Eminere 200mm, 2pcs RAL9006 (P/N 10980529) Mounting Brackets for Eminere 200mm, 2pcs RAL9011 (P/N 10980494) Mounting Brackets for Eminere 300mm, 2pcs RAL9006 (P/N 10980576) Mounting Brackets for Eminere 300mm, 2pcs RAL9011 (P/N 10980495) Mounting Brackets for Eminere 50mm, 2pcs RAL9011 (P/N 10980525)
6. Cleaning and maintenance
Eminere DANGER !
Disconnect from the mains before starting any maintenance or cleaning work
Rinse off loose dirt with low pressure water spray. Wash the housing with a soft brush or sponge and a mild, non abrasive washing detergent. Rinse it.
Maintenance and service operations are only to be carried out by a qualified person. Should you need any spare parts, please use ROBE OEM parts.
6.1 Disposing of the product
To preserve the environment please dispose or recycle this product at the end of its life according to the local regulations and codes.
7. ChangeLog
This section summarizes changes in the user manual.
Version of manual Date of issue Description of changes
1.1 07/10/2019 Inrush current added to chapter Technical Specifications 1.2 25/11/2019 Booster box added
1.3 06/01/2020 Electromagnetic emission information
1.4 22/04/2020 Technical specifications more specified
1.5 18.05/2020 Wiring of input/output connectors changed
1.6 22/06/2020 Voltage range change
1.7 10/09/2020 Booster box seal overview added
1.8 16/12/2020 New dimensions picture
1.9 22/07/2021 New accessories added
2.0 19/08/2021 Jumber cables changed in Optional accessories 2.1 13/10/2021 Technical specifications changed
2.2 26/11/2021 Optional accessories changed
2.3 17/12/2021 Jumper cable mounting added
2.4 06/01/2022 Jumper cable mounting changed
2.5 12/01/2022 Jumper cable mounting more specified
2.6 07/02/2022 Terminals 0,14 mm2 (P/N 13053403) added
2.7 23/02/2022 Sealing circle added to jumper cable mounting
2.8 19/05/2022 QR code added
2.9 08/01/2023 Eminere update added
3.0
|
10/02/2023
|
DMX chart ver. 3.2
---|---|---
Version of manual Date of issue Description of changes
3.1 05/09/2023 C-clamp adaptor installation added
3.2 13/09/2023 Jumper and leader cables numbers changed
3.3
|
26/01/2024
|
Control panel of RDM manager added, DMX chart ver. 3.3
---|---|---
Specifications are subject to change without notice.
January 26, 2024
Copyright © 2019-2024 Robe Lighting – All rights reserved
Made in CZECH REPUBLIC by ROBE LIGHTING s.r.o. Palackeho 416/20 CZ 75701 Valasske Mezirici