Anolis HP111 Pendant Remote User Manual
- May 15, 2024
- ANOLiS
Table of Contents
Anolis HP111 Pendant Remote
Specifications
- Product: Ambiane HP111 Pendant Remote
- Version: 1.7
- Power Supply: Vcc Power +, 0V Power
- Control Methods: DMX 512, DALI 0-10V
- Recommended Conductor Diameters:
- 25m – 0.5 mm²
- 50m – 1 mm²
- 75m – 1.5 mm²
- 100m – 2 mm²
Product Using Instructions
Installation Instructions
- Ensure installation is done by a qualified electrician according to national and local codes.
- Switch off the power supply before connecting or disconnecting the control unit or light unit.
- Securely fasten the control unit to the ceiling using the provided holes.
- Install terminal blocks on supply cables and connect them to PCB RB 3729 of the control unit.
- Connect terminal blocks on the DMX cable and LED unit cable to the PCB RB 3729 of the control unit.
- Set the DIP switch according to your preferred operation mode (accessible through the cover of the control unit).
- Adjust the position of the LED unit using the hanging wire and locks provided.
DMX and DALI Address Setting and Control
- The DIP switch on the control PCB (RB3729) allows you to set the
- DMX address and run a test light.
Safety Instructions
Attention
The unit must be installed by a qualified electrician by all national and local electrical and construction codes and regulations.
- The unit was designed for indoor use only.
- This unit falls under protection class III.
- Do not install the unit near highly inflammable liquids or materials.
- Do not allow anything to rest on the unit.
- Do not install the unit near an open flame.
- Do not install the unit in a dirty, dusty, or badly ventilated location.
- Avoid looking directly into the light beam at close range!
- A ceiling (structure) intended for installation of the unit(s) must safely hold at least 5 times the weight of the unit(s) fastened on it.
- The product (covers and cables) must not be exposed to a high-frequency electromagnetic field higher than 3V/m.
- Immunity of the equipment is designed according to the standard EN 55035 Electromagnetic compatibility of multimedia equipment – Immunity requirements.
Emission of the equipment complies with the standard EN55032 Electromagnetic compatibility of multimedia equipment – Emission Requirements according to class B.
This equipment has been tested and found to comply with the limits for a Class B digital device, under part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used per the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Fixture exterior view
Installation
- The Ambiance HP111 Pendant Remote must be installed by a qualified electrician according to all national and local electrical and construction codes and regulations.
- Always switch off the power supply of the control unit before connecting or disconnecting the control unit or the light unit.
- The lower ceiling (or another structure) intended for installation of the Ambiane(s) HP111 Pendant Remote must safely hold at least 5 times the weight of the Ambiane(s) HP111 Pendant Remote placed on it.
- Fasten the control unit (1) on the ceiling using two holes in the housing of the control unit.
- Fasten the ceiling plate M6i (3) to the lower ceiling.
- Screw the spherical cap (4) with the hanging wire (6) to the ceiling plate M6i (3).
- Drill the hole (diameter of 8mm) in the lower ceiling for the LED unit supply cable (7). If you wish to have the LED unit supply cable (7) parallel to the hanging wire (6), the distance between the hanging wire and the LED unit supply cable should be 34 mm.
- Secure the LED unit supply cable (7) above the ceiling against losing from the control unit (1).
- Install the terminal block (9) on the supply cable and connect it to the PCB RB 3729 of the control unit (1).
- Install the terminal block (10) on the DMX cable and connect it to the PCB RB 3729 of the control unit (1).
- Install the terminal block (11) on the LED unit cable (7) and connect it to the PCB RB 3729 of the control unit (1).
- Install another terminal block on cables according to the requirements of the current installation.
Example of connection
The green LED on the PCB signals the way of DMX address setting:
- The LED lights-DMX address is set employing the DIP switch.
- LED does not light- DMX address is set through RDM.
LED unit connection
Connector | + | A | B | – |
---|---|---|---|---|
Function | LEDs + | Data A | Data B | LEDs – |
Colour of wire | Red | White | Blue | Black |
Primary power connection
Connector | Vcc | 0V |
---|---|---|
Function | Power + | Power – |
Secondary power connection
Connector | Vcc | 0V |
---|---|---|
Function | Power + | Power – |
Recommended diameters of conductors to distance between the Control unit and the power supply (e.g. Ambiane Power HP):
Distance/cable length | 25 m | 50 m | 75 m | 100 m |
---|---|---|---|---|
Diameters of conductors | 0.5 mm2 | 1 mm2 | 1.5 mm2 | 2 mm2 |
DMX connection
Connector | D+ | D- | 0V |
---|---|---|---|
Function | Data + | Data- | Data ground(shielding) |
0-10V connection
Connector | D+ | 0V |
---|---|---|
Function | +10V | 0V |
DMX connectors are used for 0-10V control
- The primary power input serves as a standard power (e.g. Ambiane Power HP).
- The secondary power input serves as a backup power (in case the primary power fails).
- If both power inputs are under voltage, the primary power has a priority and the secondary power is disabled. In case of primary power loss, the secondary power is enabled.
- If the fixture is supplied via the secondary power, the light output of the fixture is a white color 3200K (for RGBW, TW, and TD versions only).
- Max. operating time for secondary power is 3 hours (max. power consumption is reduced to 20 W).
Set the DIP switch (12) according to your operation mode. This DIP switch is
accessible by the aperture (18) in the cover of the control unit (1).
The fixture can be controlled by one of the following methods: DMX 512 DALI
0-10V (PW or TD version only)
The fixture is equipped with two DMX and DALI connection blocks (on the PCB RB 3729) for easy connection to a DMX or DALI chain (In/Out method).
- Set the desired position of the LED unit using the hanging wire (6). If you need to pull the hanging wire (6) out of the wire lock, you have to press and hold part (16) of the wire lock.
If you need to align the LED unit, use the three locks on the hanging wires (15). To pull the hanging wire (15) out of the wire lock, you have to press and hold part (17) of the wire lock.
DMX and DALI address setting and control
The DIP switch on the control PCB (RB3729) allows you to set the DMX address
and run a test light.
DIP 10 – if it is switched to ON=test light (the fixture lights at 3200K
(for RGBW and TW version))
DIP 11 – has to be switched to OFF position to receive DMX 512 and DALI,
position ON=0-10V control
Note: If DIP 11=OFF (fixture is controlled by DMX and DALI), the last
coming command switches the fixture to the corresponding operation mode (DMX
operation by a DMX command, DALI operation by a DALI command). E.g. the
fixture stays in a DALI operation and the last coming command is a DMX command
which switches the fixture to a DMX operation. The next command is a DALI
command and switches the fixture to the DALI operation etc.
If you need the permanent DALI operation, you have to send a DALI command 8 to
the fixture.
DMX control
The DMX start address is the first channel used to receive instructions from
the DMX controller. The address may be any channel from 1 to 512. DMX address
can be set either by DIP switch or by RDM. DMX address set by RDM overwrites
address set by DIP switch and vice versa. The green LED on the PCB signals the
way of DMX address setting:
- The LED lights-DMX address is set by means of the DIP switch.
- LED does not light-DMX address is set by means of RDM.
The DIP 11 has to be set to OFF position.
Example of DMX addresses:
DALI control
- Addressing the fixture has to be made using an external DALI controller.
- If you need to start the permanent DALI control of the fixture (the fixture will not respond to DMX commands), the external DALI controller has to send an activating command (8=ON).
- If you need to stop the permanent DALI control of the fixture, the external DALI controller has to send a deactivating command (0=OFF).
0-10V control
DIP 11 has to be set in the ON position. 0-10V operation has priority to DALI
and DMX commands. The option is applicable for the PW and TD versions of the
Ambiane HP111 Pendant Remote only.
RDM
- This fixture supports RDM operation. RDM (Remote Device Management) is a bi-directional communication protocol for use in DM X512 control systems, it is the new open standard for DMX512 device configuration and status monitoring.
- RDM allows you to set a DMX address, select DMX mode, read out the software version of the fixture, etc. It is also used for fixture software updates using the Robe Uploader.
RDM model ID for the Ambiane HP111 Pendant Remote is: 0x0114.
Parameter ID | Discovery command | SET command | GET command |
---|---|---|---|
DISC_UNIQUE_BRANCH | * | ||
DISC_MUTE | * | ||
DISC_UN_MUTE | * | ||
DEVICE_INFO | * | ||
SUPPORTED_PARAMETERS | * | ||
SOFTWARE_VERSION_LABEL | * | ||
DMX_START_ADDRESS | * | * | |
IDENTIFY_DEVICE | * | * | |
DEVICE_MODEL_DESCRIPTION | * | ||
MANUFACTURER_LABEL | * | ||
DEVICE_LABEL | * | * | |
DMX_PERSONALITY | ***** | ***** | |
DMX_PERSONALITY_DESCRIPTION | ***** | ||
SENSOR_VALUE | * | * | |
SENSOR_DEFINITION | * | ||
SLOT_INFO | * | ||
SLOT_DESCRIPTION | * | ||
DEFAULT_SLOT_VALUE | * | ||
PARAMETER_DESCRIPTION | * |
Example of Control panel in RDM manager
Manufacturer PIDs:
-
DMX hold [00]- last received DMX values are held in case of DMX signal is lost.
-
DMX hold [01]- the option “DMX lost“ is activated and influences the behavior of the fixture at DMX signal lost. The default value is [00].
-
DMX lost [00]- the fixture lights on full power (dimmer open) at DMX signal lost.
-
DMX lost [01]- the fixture close light output at DMX signal was lost.
The default value is [00]. -
Power Switch [00]- the fixture uses primary power.
-
Power Switch [01]- the fixture uses secondary power.
Default value is [00].
DMX protocols
Variant RGBW, version 1.1
Mode 1
Channel
| Mode 2
Channel
| Mode 3
Channel
| Mode 4
Channel
| Mode 5
Channel
| DMX
value
| Function| Type of control
---|---|---|---|---|---|---|---
1| 1| 1| –| 1|
0-255
| Red
Red LEDs saturation control (0–>100%)
|
proportional
–| –| 2| –| –|
0-255
| Red Fine
Red LEDs saturation control (0–>100%)
|
proportional
2| 2| 3| –| 2|
0-255
| Green
Green LEDs saturation control (0-100%)
|
proportional
–| –| 4| –| –|
0-255
| Green Fine
Green LEDs saturation control (0–>100%)
|
proportional
3| 3| 5| –| 3|
0-255
| Blue
Blue LEDs saturation control (0 –>100%)
|
proportional
–| –| 6| –| –|
0-255
| Blue Fine
Blue LEDs saturation control (0–>100%)
|
proportional
4| –| 7| –| 4|
0-255
| White
White LEDs saturation control (0–>100%)
|
proportional
–| –| 8| –| –|
0-255
| White Fine
White LEDs saturation control (0–>100%)
|
proportional
–| –| 9| 1| | | Green correction|
| | | | 0| Uncorrected white| step
| | | | 1-127
128
129-
255
| Minus green –> uncorrected white Uncorrected white (128=default) Uncorrected white –> Plus green| proportional
step
proportional
–| –| 10| 2| | | Colour temperature correction (CTC)|
| | | | 0| No function (0=default)| step
| | | | 1-10| Tungsten dimming 2700 K| step
| | | | 11-20| Tungsten dimming 3200 K| step
| | | | 21-255| Colour temperature changing 2700 K–> 6500 K| proportional
–| –| 11| 3| 5|
0-255
| Dimmer
Light intensity coarse (0–>100%)
|
proportional
–| –| 12| –| 6|
0-255
| Dimmer Fine
Light intensity fine (0–>100%).
|
proportional
Variant TW, version 1.2
Mode 1
Channel
| Mode 2
Channel
| Mode 3
Channel
| Mode 4
Channel
| DMX
value
| Function| Type of
control
---|---|---|---|---|---|---
1| –| 1| –|
0-255
| White colour selection
White from 2700K–>4000K
|
proportional
–| 1| –| 1|
0-255
| Warm White
Warm white LEDs saturation control (0–>100%)
|
proportional
–| 2| –| 2|
0-255
| Cool White
Cool white LEDs saturation control (0–>100%)
|
proportional
2| 3| 2| 3|
0-255
| Dimmer
Light intensity (0–>100%)
|
proportional
–| –| 3| 4|
0-255
| Dimmer Fine
Light intensity fine (min–>max)
|
proportional
Variant TD, PW version 1.1
Mode 1
Channel
| Mode 2
Channel
| DMX
value
| Function| Type of
control
---|---|---|---|---
1| 1|
0-255
| Dimmer
Light intensity coarse (0–>100%)
|
proportional
–| 2|
0-255
| Dimmer Fine
Light intensity (0–>100%)
|
proportional
Technical specifications
- Nominal input voltage: 48V DC
- Input voltage range: 44-50V DC
- Max. power consumption (primary power): 75W
- Max. power consumption (secondary power): 20W
- Max. operating time for secondary power: 3 hours
- Light source: High Power LED module
- Beam angle: 20°, 40°,60°, 80°
- Projected Lumen Maintenance: L90B10 >90.000 hrs, Ta = 25°C / 77°F °F)
- Color Variants: RGBW (W – 2700K or 4000K), PureWhite, Tunable White, Tungsten Dim
- Color Temperature of White : PW 2700 K or 4000K, TW 2700 – 4000K, TD 3200K CRI: 90+
- Control: DMX, DALI 2 , RDM, 0-10V
- Settings/Addressing: DIP Switch, RDM
- DMX channels (RGBW variant): 4 (Mode 1), 3 (Mode 2), 12 (Mode 3), 3 (Mode 4), 6 (Mode 5)
- DMX channels (TW variant): 2 (Mode 1), 3 (Mode 2), 3 (Mode 3), 4 (Mode 4)
- DMX channels (TD, PW variant): 2 (Mode 1), 2 (Mode 2)
- Power supply (CE): Ambiane Power HP (48V/100W), Ambiance Power Rack
- Power supply (US): Ambiane Power HP (48V/100W), Ambiance Power Rack US
- Operating ambient temp. range: -20 °C / +40 °C (-4 °F / +104 °F)
- Operating Temperature (LED unit): +75 °C @ Ambient +40 °C (167 °F @ Ambient 104 °F)
- Total heat dissipation: 191 BTU/h (calculated)
- Cooling: convection
- Housing: High-Pressure Die-Cast Aluminium Body
- Weight (without control unit) :
- Ambiane HP111 Pendant Remote 20° 3.1 kg/ 6.8 lbs
- Ambiane HP111 Pendant Remote 40° 3.1 kg/ 6.8 lbs
- Ambiane HP111 Pendant Remote 60° 3.0 kg/ 6.6 lbs
- Ambiane HP111 Pendant Remote 80° 3.0 kg/ 6.6 lbs
- Mounting Method: Pendant with 1 adjustable hanging wire
- IC rating: Non-IC rated
- Power connection Connectors
- DMX connection: Connectors
- DALI connection: Connectors
- LED unit connection: Connector
- Protection factor (CE): IP20
- Protection factor (US): Dry location only
Dimensions
mm [inch]
- Ambiane HP 20° H = 302 mm [11 7/8 in.]
- Ambiane HP 40° H = 298 mm [11 3/4 in.]
- Ambiane HP 60° H = 285 mm [11 1/4 in.]
- Ambiane HP 80° H = 268 mm [10 9/16 in
Control unit
Included items
- 1 x Ambiane HP111 Pendant Remote
- 1 x Control unit
- 1 x Set of cable connectors
- 1 x User manual
Optional accessories
- Ambiane Power HP (MeanWell ELG-100-48-3Y) (P/N 10064073)
- Ambiance Power Rack (P/N 10063951), black color
- Ambiance Power Rack US (P/N 10063873), black color
Cleaning and maintenance
Disconnect from the mains before starting any maintenance work
- Keep the fixture clean, especially the light source and the ribbed ribbed heat sink.
- Maintenance and service operations are only to be carried out by a qualified person.
- Should you need any spare parts, please use ROBE OEM parts.
Software update
The fixture has to be connected to power during software updates.
Software update using the Robe Uploader
The ROBE Uploader is a software for automatized software updates of Robe and
Anolis fixtures. It can take advantage of RDM support.
The fixtures have to be connected in a daisy chain (max. 32 fixtures) and via
the Robe Universal Interface/Robe Universal Interface WTX and a USB cable
connected to the control PC with the Robe Uploader running.
The fixtures have to be connected to power. The control PC should be connected
to the Internet.
Ambiane HP111 Pendant Remote
- The Robe Uploader software and user manual is available at https://www.robe.cz/robe-uploader/
- If you do the software update through the Robe Uploader, switching fixtures to the update mode (and from the update mode) is made automatically.
Note: The Robe Uploader software cannot be used if fixtures are connected through a DALI connection.
Disposing of the product
To preserve the environment please dispose or recycle this product at the end
of its life according to the local regulations and codes.
FAQ
- Q: Can I install the Ambiane HP111 Pendant Remote myself?
- A: No, it must be installed by a qualified electrician following all safety regulations.
- Q: How do I set the DMX address for control?
- A: Use the DIP switch on the control PCB (RB3729) to set the DMX address.
February 16, 2024
Copyright © 2022-2024 Robe Lighting – All rights reserved
All Specifications subject to change without notice
Made in CZECH REPUBLIC by ROBE LIGHTING s.r.o. Palackeho 416/20 CZ 75701
Valasske Mezirici
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>