Anolis ArcPower 24 Outdoor Wireless DMX User Manual

June 3, 2024
ANOLiS

ArcPower 24 Outdoor Wireless DMX
Anolis ArcPower 24 Outdoor Wireless DMX - Featured
Image User Manual
Version 2.0 CE

ArcPower 24 Outdoor Wireless DMX

FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE POWERING OR INSTALLING YOUR ArcPower 24 Outdoor !
Save it for future reference.
This device has left our premises in absolutely perfect condition. In order to maintain this condition and to ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning notes written in this manual.
The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unauthorized modification to the device.
Please consider that damages caused by manual modifications to the device are not subject to warranty.

Safety instructions

DANGEROUS VOLTAGE CONSTITUTING A RISK OF ELECTRIC SHOCK IS PRESENT WITHIN THIS UNIT!

This fixture should be operated only from the type of power source indicated on the marking label. If you are not sure of the type of power supplied, consult your authorized distributor or local power company.
Always disconnect the fixture from AC power before cleaning, removing or installing the fuses, or any part. Do not overload wall outlets and extension cords as this can result in fire or electric shock.
Make sure that the power cord is never crimped or damaged by sharp edges. Check the fixture and the power cord from time to time.
Do not install the unit near naked flames. During the operation the housing becomes hot (up to 80°C) Refer servicing to qualified service personnel.
This fixture falls under protection class I. Therefore this fixture has to be connected to a mains socket outlet with a protective earthing connection.
Do not connect this fixture to a dimmer pack. Keep compustible materials at least 20 cm away from the fixture.
If the fixture has been exposed to drastic temperature fluctuation (e.g. after transportation), do not switch it on immediately.
The arising condensation water might damage your device. Leave the device switched off until it has reached room temperature. Avoid brute force when installing or operating the fixture. The fixture was designed for outdoor use. This fixture must not be used for underwater installation.
When choosing the installation spot, please make sure that the fixture is not exposed to extreme heat or dust. Avoid using the unit in locations subject to possible impacts.
The fixture body never must be covered with cloth or other materials. Only operate the fixture after having checked that the housing is firmly closed and all screws are tightly fastened. Make sure that the area below the installation place is blocked when rigging, derigging or servicing the fixture.
The fixture becomes very hot during operation. Allow the fixture to cool approximately 30 minutes prior to manipulate with it. Operate the fixture only after having familiarized with its functions. Do not permit operation by persons not qualified for operating the fixture. Most damages are the result of unprofessional operation!
Do not attempt to dismantle or modify the unit. Please consider that unauthorized modifications on the fixture are forbidden due to safety reasons!
Please use the original packaging if the fixture is to be transported. If this device will be operated in any way different to the one described in this manual, the product may suffer damages and the guarantee becomes void. Furthermore, any other operation may lead to dangers like shortcircuit, burns, electric shock etc.
Immunity of the equipment is designed for electromagnetic environments E1, E2, E3 according to the standard EN55103-2 ed.2 Electromagnetic compatibility. Product family standard for audio, video, audiovisual and entertainment lighting control apparatus for professional use.
Part 2: Immunity.
The installation company should check levels of possible interferences above the tested levels E1,E2,E3 given by this standard (e.g. transmitters in surrounding area) before installing the equipment. Emission of the equipment complies with the standard EN55032 Electromagnetic compatibility of multimedia equipment – Emission Requirements according to class B.
Warning for fixtures with Harsh Environment Finish (HEF):
Handle with care!
Avoid any damage to the painted surface.
Damaging the paint may result in corrosion and loss of warranty.

Fixture exterior view

Anolis ArcPower 24 Outdoor Wireless DMX - Featured
Image

  1. Antenna (only wireless DMX version)
  2. Control board with anti-vandal cover
  3. Housing
  4. Power/data input
  5. LED input

Installation

Note

  1. Before connecting a LED module, check its technical data in order to set the correct LED current and find out if the LED module includes a temperature sensor. See the Arc Power 24 outdoor menu “Personality” “Load” and “Personality” “Temp Sen” .
  2. Do not overload the Arc Power 24 Outdoor.
  3. Only one LED module with the temperature sensor can be connected to the Arc Power 24 Outdoor.
  4. Mixing LED modules without temperature sensor and with temperature sensor is not allowed.
  5. Max. length of connection cable between the Ar Power 24 Outdoor and the LED module should not exceed 20 metres.

3.1 Mounting the fixture
The ArcPower 24 Outdoor can be arranged in any position orientation.

Anolis ArcPower 24 Outdoor Wireless DMX - Featured
Image

Four holes with diameter of 5.3mm in the control unit are intended for mounting on a flat, non-flammable surface. The length of the connection cable between the Arc Power 24 Outdoor and the LED unit should not exceed 20 m (at 700mA load) or 80m (at 350mA load).
Warning for wireless DIX version of the Arc Power 24 Outdoor!
The fixture is supplied with the cap screwed on the antenna connector. This cap provides declared IP rating of the fixture but when the cap is removed, the enclosed antenna must be installed on the fixture to keep declared IP rating of the fixture!
3.2 Connection to the mains
Fixtures must be installed by a qualified electrician in accordance with all national and local electrical and construction codes and regulation.
The Arc Power 24 Outdoor is equip ed with with a 5-cored power/data cable. The 3 cores serve for the power supply (3 x 1.5mm 2 ) and next 2 shielded cores are intended for DMD connection as shown in the table.

Core Connection Core Connection
Black Live Red Data +
Blue Neutral White Data –
Yellow/Green Shielding 0

Anolis ArcPower 24 Outdoor Wireless DMX - Featured
Image

Connect the junction box acording to the tables below
Power connection

| L| N|
---|---|---|---
EU| Braun| Blue| Green/yellow

Do not overload the supply line and the connecting leads.
DMX connection

+ 0
Data + Data ground(shielding) Data –

Remove end caps from cable glands before passing cables into the junction box. The four cable glands M20 with standard seals serve for cable of diameter of 6-12mm, for smaller diameter of cable (4-8mm) you have to remove original sealing from the cable gland M20 and use the enclosed reducing seal instead it. Four reducing seals for diameter of cable 4-8mm (P/N 13051388) are enclosed.
Fully tighten cable gland nuts and check that cables are properly fastened in the cable glands.
Note: To keep declared IP rating, every cable gland has to be covered with the end cap if this cable gland is not used for cable passing.
Screw the cover of the junction box and check that it is fully tighten.

Anolis ArcPower 24 Outdoor Wireless DMX - Featured
Image

3.3 Wiring of the LED input connector

Anolis ArcPower 24 Outdoor Wireless DMX - Featured
Image

4. ArcPower 24 Outdoor (RGBW) – DMX protocol
Version 1.1

Mode/Channel| Value| Function|

Type of control

---|---|---|---
1| 2| 3| 4
–| 1| 1| 1| 0 – 255| Red LEDs

Red LEDs saturation control (0-100%)

| proportional
–| 2| 2| 2| 0 – 255| Green LEDs
Green LEDs saturation control (0-100%)| proportional
–| 3| 3| 3| 0 – 255| Blue LEDs
Blue LEDs saturation control (0-100%)| proportional
–| –| 4| 4| 0 – 255| White LEDs
White LEDs saturation control (0-100%)| proportional
–| –| –| 5| | CT0|
| | | | 0| No function|
| | | | 1-255| Colour temperature correction (0-100%)| proportional
1| –| –| 6| | Virtual colour wheel|
| | | | 0| No function (for DMX mode 4)| step
| | | | | White (R+G+B+W=full for DMX mode 1)|
| | | | 1-2| White 2700 K| step
| | | | 3| White 2700 K (Halogen lamp mode)| step
| | | | 4-5| White 3200 K| step
| | | | 6| White 3200 K (Halogen lamp mode)| step
| | | | 7-9| White 4200 K| step
| | | | 10-12| White 5600 K| step
| | | | 13-15| White 8000 K| step
| | | | 16| Blue (Blue=full, Red+Green+White=0)| step
| | | | 17-55| Red=0, Greenàup,Blue =full, White=0| proportional
| | | | 56| Light Blue (Red=0, Green=full, Blue =full, White=0)| step
| | | | 57 – 95| Red=0, Green=full, Blueàdown, White=0| proportional
| | | | 96| Green (Red=0, Green=full, Blue =0, White=0)| step
| | | | 97 – 134| Redàup, Green=full, Blue=0, White=0| proportional
| | | | 135| Yellow-green (Red=full, Green=full, Blue=0, White=0)| step
| | | | 136 – 174| Red=full, Greenàdown, Blue=0, White=0| proportional
| | | | 175| Red (Red=full, Green=0, Blue=0, White=0)| step
| | | | 176 -214| Red=full, Green=0, Blueàup, White=0| proportional
| | | | 215| Magenta (Red=full, Green=0, Blue=full, White=0)| step
| | | | 216 – 246| Redàdown, Green=0, Blue=full, White=0| proportional
| | | | 247| Blue (Red=0, Green=0, Blue=full, White=0)| step
| | | | 248-251| Rainbow effect with fade time (fast àslow)| proportional
| | | | 252-255| Rainbow effect without fade time (fast àslow)| proportional
–| –| –| 7| | Shutter/ Strobe|
| | | | 0-31| Shutter closed| step
| | | | 32-63| Shutter open| step
| | | | 64-95| Strobe-effect from slow to fast| proportional
| | | | 96-127| Shutter open| step
| | | | 128-143| Opening pulses in sequences slow–> fast| proportional
| | | | 144-159| Closing pulses in sequences fast –> slow| proportional
| | | | 160-191| Shutter open| step
| | | | 192-223

224-255

| Random strobe-effects from slow to fast Shutter open| proportional step
2| –| –| 8| 0 – 255| Dimmer
Dimmer intensity from 0% to 100%| proportional
–| –| –| 9| 0 – 255| Dimmer fine Fine dimmer intensity from low to high| Proportional

  1. 1  ArcPower 24 Outdoor (RGBA) – DMX protocol

Version 1.0

Mode/Channel

| Value| Function|

Type of control

---|---|---|---
1| 2| 3| 4
–| 1| 1| 1| 0 – 255| Red LEDs

Red LEDs saturation control (0-100%)

| proportional
–| 2| 2| 2| 0 – 255| Green LEDs
Green LEDs saturation control (0-100%)| proportional
–| 3| 3| 3| 0 – 255| Blue LEDs
Blue LEDs saturation control (0-100%)| proportional
–| –| 4| 4|

0 – 255

| Amber LEDs
Amber LEDs saturation control (0-100%)| proportional
–| –| –| 5| | CT0|
| | | | 0| No function|
| | | | 1-255| Colour temperature correction (0-100%)| proportional
1| –| –| 6| | Virtual colour wheel|
| | | | 0| No function (for DMX mode 4)| step
| | | | | White (R+G+B+W=full for DMX mode 1)|
| | | | 1-2| White 2700 K| step
| | | | 3| White 2700 K (Halogen lamp mode)| step
| | | | 4-5| White 3200 K| step
| | | | 6| White 3200 K (Halogen lamp mode)| step
| | | | 7-9| White 4200 K| step
| | | | 10-12| White 5600 K| step
| | | | 13-15| White 8000 K| step
| | | | 16| Blue (Blue=full, Red+Green+White=0)| step
| | | | 17-55| Red=0, Greenàup,Blue =full, White=0| proportional
| | | | 56| Light Blue (Red=0, Green=full, Blue =full, White=0)| step
| | | | 57 – 95| Red=0, Green=full, Blueàdown, White=0| proportional
| | | | 96| Green (Red=0, Green=full, Blue =0, White=0)| step
| | | | 97 – 134| Redàup, Green=full, Blue=0, White=0| proportional
| | | | 135| Yellow-green (Red=full, Green=full, Blue=0, White=0)| step
| | | | 136 – 174| Red=full, Greenàdown, Blue=0, White=0| proportional
| | | | 175| Red (Red=full, Green=0, Blue=0, White=0)| step
| | | | 176 -214| Red=full, Green=0, Blueàup, White=0| proportional
| | | | 215| Magenta (Red=full, Green=0, Blue=full, White=0)| step
| | | | 216 – 246| Redàdown, Green=0, Blue=full, White=0| proportional
| | | | 247| Blue (Red=0, Green=0, Blue=full, White=0)| step
| | | | 248-251

252-255

| Rainbow effect with fade time (fast slow) Rainbow effect without fade time (fast slow)| proportional proportional
–| –| –| 7| 0-31

32-63

64-95

96-127

128-143

144-159

160-191

192-223

224-255

| Shutter/ Strobe
Shutter
closed
Shutter open
Strobe-effect from slow to fast
Shutter open
Opening pulses in sequences slow–> fast
Closing pulses in sequences fast –> slow
Shutter open
Random strobe-effects from slow to fast
Shutter open| step
step
proportional
step
proportional
proportional
step
proportional
step
2| –| –| 8| 0 – 255| Dimmer
Dimmer intensity from 0% to 100%| proportional
–| –| –| 9| 0 – 255| **Dimmer fine
** Fine dimmer intensity from low to high| Proportional

4.2 ArcPower 24 Outdoor (SmartWhite) – DMX protocol
Version 1.0

Mode/Channel| Value| Function|

Type of control

---|---|---|---
1| 2| 3
1| –| 1| 0 – 255| Warm white LEDs
Warm white LEDs saturation control (0-100%)| proportional
2| –| 2| 0 – 255| Cool white LEDs
Cool white LEDs saturation control (0-100%)| proportional
–| 1| 3| | Colour wheel|
| | | 0| No function|
| | | 1-2| White 2800 K| step
| | | 3-4| White 3200 K| step
| | | 5-6| White 3800 K| step
| | | 7-8| White 4200 K| step
| | | 9-10| White 4600 K| step
| | | 11-12| White 5000 K| step
| | | 13-14| White 5600 K| Step
| | | 15-16| White 6300 K| step
| | | 17-247| Warm white –> Cool white| proportional
| | | 248| Rainbow effect (with fade time)| step
| | | 249| Rainbow effect| step
| | | 250-255| Reserved|
–| –| 4| | Strobe|
| | | 0-31| Shutter closed| step
| | | 32-63| Shutter open| step
| | | 64-95| Strobe-effect from slow to fast| proportional
| | | 96-127| Shutter open| step
| | | 128-143

144-159

160-191

192-223

224-255

| Opening pulses in sequences slow–> fast
Closing pulses in sequences fast –> slow
Shutter open
Random strobe-effects from slow to fast
Shutter open| proportional
proportional
step proportional
step
–| 2| 5| 0 – 255| Dimmer
Dimmer intensity from 0% to 100%| proportional

|

| 6| 0 – 255| Dimmer fine
Fine dimmer intensity from low to high| proportional

4.3 ArcPower 24 Outdoor (Single colour) – DMX protocol
Version 1.0

Mode/Channel

| Value| Function|

Type of control

---|---|---|---
1| 2
–| 1| 0-31
32-63
64-95
96-127
128-143
144-159
160-19
192-223
224-255| Strobe Shutter closed Shutter open
Strobe-effect from slow to fast Shutter open
Opening pulses in sequences slow–> fast
Closing pulses in sequences fast –> slow
Shutter open Random strobe-effects from slow to fast
Shutter open| step
step
proportional
step
proportional
proportional
step
proportional
step
1| 2| 0 – 255| Dimmer
Dimmer intensity from 0% to 100%| proportional
–| 3| 0 – 255| Dimmer fine
Fine dimmer intensity from low to high| proportional

Control menu map

Default settings=Bold print

Menu Level 1| Menu Level 2| Menu Level 3| Menu Level 4| Menu Level 5| Menu Level 6
---|---|---|---|---|---
DMXA 0001| Set DMXA| 0001-0512| | |
| | | | |
InFo| POn Time.| Total| | |
| | Reset| | |
| | | | |
| DMX In| REd| 0-255| |
| | :| | |
| | Dimmer F| 0-255| |
| Temp.| Current| Led| |
| | | Board| |
| | Highest| Led| |
| | | Board| |
| | High Res.| Led| |
| | | Board| |
| Sw Ver.| IC-1| | |
| | IC-2| | |
| | | | |
PErS| DMX Pres| Mod.1| | |
| | Mod.2| | |
| | Mod.3| | |
| | Mod.4| | |
| DMX In| Wired| | |
| | Wireless| | |
| | Wrle Out| | |
| | Analog 0-10V| | |
| M. FTime| 0.1 -25.5| | |
| Display| Turn| | |
| | On/Off T| On, Off| |
| | Contrast| 0-100%| |
---|---|---|---|---|---
| | Backlight| 0-100%| |
| Load| 350mA, 700mA| | |
| RGB Cnt| Active, Deactive| | |
| Temp Uni| °C , °F| | |
| Temp Sen| yes ,no| | |
| I Ef Pos| Red| 0-255| |
| | Green| 0-255| |
| | Blue| 0-255| |
| | White| 0-255| |
| | CTC| 0-255| |
| | C Wheel| 0-255| |
| | Strobe| 0-255| |
| | Dimmer| 0-255| |
| | Dimmer F| 0-255| |
| | Store| | |
| Defaults| | | |
| | | | |
Manual| Red| 0-255| | |
| :| :| | |
| Dimmer F| 0-255| | |
| | | | |
Test Prg| | | | |
| | | | |
St ALone| Auto Run| Off| | |
| | Test| | |
| | Prog 1| | |
| | :| | |
| | Prog 3| | |
| Pr Play| Test Prg| | |
| | Prog 1| | |
| | :| | |
---|---|---|---|---|---
| | Prog 3| | |
| Pr Edit| Prog 1| Step 01| Prg End| 1-40
| | :| :| Red| 0-255
| | Prog 3| Step 40| :| :
| | | | F.Tim.| 0-25.5 sec
| | | | Copy|
Special| rdM Low| | | |
| rdM High| | | |
| LED type| RGBW| | |
| | Sin. Col.| | |
| | RGBA| | |
| | Smart. W.| | |
| Wireless| Stat, Unlink| | |
| IniBlink| On, Off| | |
| Hold DMX| On, Off| | |
| Flicker freeM| On, Off| | |
| Adjust| DMX Val| Red| 0-255|
| | | :| |
| | | Dimmer F| 0-255|
| | Cal Col| Red C| 0-255|
| | | :| |
| | | Store| |
| | Cal.temp| 2700K| |
| | | | Red C| 0-255
| | | | :|
| | | | Whi C| 0-255
| | | | Store|
| | | 3200K| |
| | | 4200K| |
| | | 5600K| |
| | | 8000K| |
---|---|---|---|---|---
| | | Cal.Def.| |
| Sw Upd| No/Yes| | |

Fixture menu

The control panel menu allows to set the fixture according to your needs, obtain information on its operation and manual control of all effects.
The four control buttons on the front have the following functions:
ESCAPE button-leaves menu without saving changes.
ENTER button- enters menu, confirms adjusted values and leaves menu.
UP and  DOWN buttons – move between menu items on the same level, sets values.
6.1 Fixture Address
DMX 0001
Use this menu to set the DIX address of the fixture.
Set DMCA — Set DIX address. Select this submenu to set a DIX start address.
To set a DIX address.

  1. Use the UP/DOWN buttons to find “ DMCA/0001“ menu.
  2. Press the ENTER button.
  3. Use the UP/DOWN buttons to select desired start address.
  4. Press the ENTER button to confirm the choice.

Note: After switching on, the Arc Power 24 Outdoor will automatically detect whether DMX 512 data is received or not.
If there is no data received at the DIX input, the display will start to flash with actually set address.
6.2 Fixture information
Info

Use this menu to read useful information about the fixture status.
To display desired information.

  1. Use the UP/DOWN buttons to find the “ InFo“ menu.
  2. Press the ENTER button.
  3. Use the UP/DOWN buttons to select the required menu item.
  4. Press the ENTER button to confirm the choice.

Pon Time —Power On Time. Use the menu item to read the number of operation hours of the fixture.
Total – the function shows the total number of the operation hours since the ArcPower 24 Outdoor has been fabricated.
Reset – the function shows the number of the operation hours that the ArcPower 24 Outdoor has been powered on since the counter was last reset.
In order to reset this counter to 0 you have to press and hold the UP and DOWN buttons and at the at the same time press the ENTER button.
DM In —DMX values. Select this function to read DMX values of each channel received by the fixture.
Temp —Fixture Temperatures. Select this menu to read the temperatures:
Current — the current temperature of the LED driver/LED module.
Highest – the menu item shows the max. temperatures of the LED driver/LED module since the ArcPower 24 Outdoor has been fabricated.
High Res. — the menu item shows the maximum temperatures of the LED driver/LED module since the counter was last reset. In order to reset this counter to 0 you have to press and hold the UP and DOWN buttons and at the at the same time press the ENTER button.
Measuring points: Led- a temperature inside the connected LED module Board- a temperature inside the ArcPower 24 Outdoor In case that LED module does not include temperature sensor, the sign “N/A” will be displayed.
Note: The ambient temperature should not exceed 40°C.
The temperatures can be displayed in either °C or °F units – see option “tEM.U“ in the menu “Pers“.
Sw Ver —Software Versions. Select this function to read the software version of the fixture processors.
6.3 Personality
**Pers**
Use this menu to modify the ArcPower 24 Outdoor operating behaviour.
DMX Pres — DMX preset. Select this menu item to set a desired DMX mode. Please refer to the chapter “DMX
protocol” for detail description of each DMX mode.
DMX In — DMX inpu t. Use the menu to select mode of receiving DMX signal:
Wired – DMX s ignal is received by means of the standard DMX cable.
Wireless – DMX signal is received by means of the inbuilt wireless module (wireless DMX version only).
Wrle Out – the fixture receives wireless DMX and sends the signal to its wired DMX output.
The fixture behaves as ” Wireless/Wired” adapter (wireless DMX version only).
E.g. You have 5 fixtures, one fixture is equipped with the wireless DMX module and 4 fixtures are standard fixtures without wireless DMX module. The first fixture receives wireless DMX and sents this signal to the rest of fixures, which are connected to the first fixture by means of the DMX cable in a DMX chain.
Analog 0-10V — Analog dimmer. If this option is selected, the dimmer channel can be controlled via DC voltage (0-10V) connected between pins 1 (data ground) and 3 (Data +) of DMX input of the fixture (0-data ground, 10V- data +).
Procedure of setting:

  1. Set fixture´s channels at desired values (by means of menu item Init Effect Positions “I. Ef.Pos”).
  2. Disconnect DMX controller
  3. Select option “Ana log 0-10V” from menu DMX input
  4. Connect DC voltage to the DIX input of the fixture

M FTime — Max. Fade time. Select this menu item to set a desired max. fade time (0-25.5 sec.). This adjusted fade time influences fade of Red, Green, Blue,White and dimmer during DMX operation:
If time between two receiving DMX values is > than fade time set in the item “M Ftime“, the entire adjusted fade time will be used.
If time between two receiving DMX values is < than fade time set in the item“M Ftime“, the adjusted fade time will be reduced to fill entire time between the two receiving DMX values. e.g “M Ftime“=2sec. and fixture has received Red=0 DMX, after 5 seconds will receive Red=255 DMX. It means, that red will go to full intensity during 2 seconds.
“M Ftime“=8 sec. and fixture has received Red=0 DMX, after 5 seconds will receive Red=255 DMX. It means, that red will go to full intensity during 5 seconds. (Max, fade time is reduced from 8 sec. to 5 sec.).
Display — Display adjusting. This function allows you to change the display settings.
Turn – This function turns the display by 180°.
On/Off T – This function allows you to keep the display permanent on or turn it off two minutes after last pressing any button on the control panel.
Contrast – Use this function to adjust contrast of the display (0-100%).
Backlight – Use this function to adjust backlight of the display (0-100%).
Load — Current load. This function allows you to set desired current for connected LED module: 350 mA 700 mA
See technical information about LED module before connecting it to the driver!
RGB Cnt — RGB counting (RGBW version only). If this function is active, the white channel (channel 4) uses red, green and blue chanels in proportional relation to ensure max. light output in a white colour ( if white channel =full, also red, green and blue channels are full). If you want to light with white channel only (without RGB channels), the function has to be deactivated.
Display — Display adjusting. This function allows you to change the display settings.
Turn – This function turns the display by 180°. On/Off T – This
Temp Uni — Temperature Unit. Use this menu in order to display the fixture temperatures in desired units: °C or°F.
Temp Sen — Temperature sensor. If this function is On, the ArcPower 24 Outdoor measures inside temperature of the connected LED module and according to the temperature reduces LED current to prevent overheating of the
LED module. The LED module has to be equipped temperature sensor. If a LED module is without temperature sensor, this option must be set Off.
Note: in case that Temp Sen=On and the connected LED module is without a temperature sensor, the following error message will appear “Temp Sen Error”. To cancel this message, set Temp Sen=Off.
I Ef Pos — Init effect positions. Use this function to set all effects to the desired positions to which they will move after switching the fixture on (if DMX is not being received).
Defaults — Default Settings . The menu item sets all fixture parameters to the default (factory) values.
6.4 Manual mode
Manual

Use this menu for control the fixture without connected DMX console.
To control fixture channels.

  1. Use the UP/DOWN buttons to find “ Manual“ menu.

  2. Press the ENTER button.

  3. Use the UP/DOWN buttons to select desired effect (channel).
    List of control channels:
    “Red” – red LED’s saturation
    “Green“ – green LED’s saturation’s
    “Blue“ – blue LED’s saturation
    “White“ – white LED saturation
    “C TC“ – a colour temperature correction
    “C Wheel“ – a virtual colour wheel
    “Strobe“- a strobe, shutter
    “Dimmer“- a dimmer
    “Dimmer F” a fine dimmer

  4. Press the ENTER button and use the UP/DOWN buttons to set value , press the ENTER button to confirm

6. 5 Test sequences
Use this menu to run demo-test sequences without an external controller, which will show you some possibilities of using the ArcPower 24 Outdoor .
6.6 Stand-alone setting
The fixtures on a data link are not connected to the controller but can execute pre-set programs which can be different for every fixture.
Auto Run — Automatic playback. This function allows you to select the program which will be played after switching the fixture on. Selected program will be played continuously in a loop.

  1. Use the UP/DOWN buttons to find “ Sta Alone“ menu.
    2. Press the ENTER button.
    3. Use the UP/DOWN buttons to select “ Auto Run“ item.
    4. Press the ENTER button.
    5. Use the UP/DOWN buttons to select desired program.
    6. Press the ENTER button to confirm the choice.

Pr Play — Playing program. By enter to this menu a complete overview of all programs is offered, from which the program to be run can be selected.

  1. Use the UP/DOWN buttons to find “Pr Play“ menu.
  2. Press the ENTER button.
  3. Use the UP/DOWN buttons to select desired program.
  4. Press the ENTER button. The selected program runs in a loop.

Pr Edit — Editing a program. The fixture offers 3 freely editable programs (Prog.1-Prog.3) each up to 40 steps.
Every program step includes a fade time-the time taken by the step´s channel status to reach the desired level and a step time-the total time occupied by the step in the program.
E.g. If “F.tim.“=5 second and “S.tim.“=20 second, effects will go to the desired position during 5 seconds and after that they will stay in this position for 15 seconds before going to the next prog. step

  1. 1. Use the UP/DOWN buttons to find “ Sta Alone“ menu and press the ENTER button.

  2. Use the UP/DOWN buttons to select “Pr Edit“ menu and press the ENTER button.

  3. Use the UP/DOWN buttons to select a program you want to edit (Prog.1-Prog.3) and press ENTER button.

  4. Use the UP/DOWN buttons to select a desired program step (“Step 01” – “Step 40”) and press ENTER button.

  5. Use the UP/DOWN buttons to select a channel you want to edit and press the ENTER button.
    List of editable items:
    “Prg.En” – a total number of program steps (value 1-40). This value should be set before start programming (e.g. if you want to create program with 10 steps, set Prg.En=10). “Red” – red LEDs saturations
    “Green“ – green LEDs saturations
    “Blue“ – blue LEDs saturations
    “White“ – white LEDs saturations
    “C TC“ – a colour temperature correction
    “C Wheel“ – a virtual colour wheel
    “Strobe“- a strobe, shutter
    “Dimmer“- a dimmer
    “Dimmer F” a fine dimmer
    “F.tim.“- a fade time, (0-25.5) seconds
    “S.tim.“ – step time, value (0-25.5) seconds
    “COPY“. – this item duplicates the current prog. step to the next prog. step. The item “Prg En” is increased automatically.

  6. Use the UP/DOWN buttons to set a DMX value of the channel and then press the ENTER button.

  7. Use the UP/DOWN buttons to select next channel and press the ENTER button.

  8. After having set all channels in the current program step, press the MODE button to go by one menu level back and select another program step.

6.7 Special functions
rdM Low — RDM Code. This menu item shows the first part of the RDM identification code.
rdM High — RDM Code. This menu item shows the second part of the RDM identification code.
LED type — LED colour variant. This menu allows to set desired colour variant according to connected
LED module.
RGBW – RGBW variant.
GRAB – GRAB variant.
Sin. Col.– Single colour variant.
Smart W.– Smart white variant.
Note: The menu items and DMX chart will be changed according to set colour variant!
Wireless — Wireless state. This menu serves for reading of the state of wireless operation (Wireless DMX only).
Unlink – The item serves for unblinking the fixture from the transmitter (Wireless DMX version only)
IniBlink — Initial blink. If this function is on, the fixture makes auto- calibration (each LED colour lits on 100% for short time) after switching the fixture on.
HoLd DMX — – If the function is on, the last received DMX values are held in case, that DMX data receiving was interrupted (e.g. disconnected DMX controller).
Flicker Free M —Flicker free mode. If the function is ON, the light flickering visible in cameras is corrected but colour uniformity is worse (LEDs output frequency varies from 300Hz to 153.8kHz depending on the dimmer level).
When flicker free mode is OFF, LEDs output frequency is 300Hz at all times.
Adjust – Adjustment. The menu allows the fine adjustment of colours.
DMX Val- DMX values. Use the menu to set DMX values of fixture´s channels.
Cal Col – A calibration o red, green, blue and white colours by means of an automatic calibration with a factory equipment.
Grn C – green LEDs saturation (0-255)
Blu C – blue LEDs saturation (0-255)
Whi C – white LEDs saturation (0-255)
Cal Temp – Selection of colour temperature for manual calibration: 2700K, 3200K, 4200 8000K.
Red C – red LEDs saturation (0-255)
Manual colour calibration:

  1. Connect the fixture to the mains , go to the “Manual” menu and set the shutter,dimmer, red, green, blue and white channel at 255DMX and let the LED module heat up (cca 1 hour).
  2. Go to the “Manual” menu and set the C Wheel at 1 DMX (2700K)
  3. Go to the “CalCol” menu, select “2700K” item and by means of the Red C, Green C, Blue C and White C items adjust the 2700K colour temperature as exactly as possible (∆u´v´= 0). After calibration, press the “Store“ item to save adjusted values.
  4. Go to the “Manual” menu and set the C Wheel at 4 DMX (3200K).
  5. Go to the “CalCol” menu, select “3200K” item and by means of the Red C, Green C, Blue C and White C items adjust the 3200K colour temperature as exactly as possible (∆u´v´= 0). After calibration, press the “Store“ item to save adjusted values.
  6. Repeat this procedure for rest of colour temperatures (4200K, 5600K,8000K).

SW Upd — Software update. The menu item allows you to update software in the fixture via either serial or USB port of PC.
The following are required in order to update software:
– PC running Windows or Linux or macOS – DSU file
– Flash cable RS232/DMX P/N13050624 (if you want to use a serial port of PC)
– Robe Universal Interface or Robe Universal interface WTX (if you want to use an USB port of PC) After the software updating the fixture will be set to default (factory) values.
To update software in the fixture:

  1. DSU file is available from Robe web site at https://www.robe.cz/architectural/download/#software-updates
    File with extension zip is intended for Windows (used and tested from XP to W10 on 32/64bit systems).
    File with extension tbz is intended for Linux (used and tested on Debian and Ubuntu 32/64bit).
    File with extension dmg is intended for macOS (used and tested on OSX up to Sierra) XQuartz required,
    install it from https://www.xquartz.org/
    Save the download file to a folder on your computer.
    In case that you use windows, extract files in the zip file (e.g. DSU_ArcPowerOutdoor24_18120641.zip)

  2. Disconnect the fixture from DMX controller.

  3. If you use the flash cable RS232/DMX, connect a serial port of your computer with DMX input of the fixture by means of the cable.
    If you use the Robe Universal Interface, connect a USB port of your computer with the Robe Universal Interface by means of the USB cable and DMX input of the fixture with the DMX output of the Robe Universal Interface via a DMX cable.

  4. Switch the fixture to the update mode (Special –> Sw Upd –>Yes).
    Note: If you do not want to continue in the software update, you have to switch off and on the fixture to escape from the updating mode.
    We recommend to cancel all running programs on your computer before starting the software update.

  5. Double-click the software uploader file (e.g. DSU_ArcPowerOutdoor24_18120641.exe) in the extracted files. The Software Uploader program will start running. Anolis ArcPower 24 Outdoor Wireless DMX - Featured Image

  6. Select correct “COM ” number if you use a Flash cable RS232/DMX or select “Robe Universal Interface ” if you use the Robe Universal Interface/Robe Universal Interface WTX and then click on the “Connect” button.

If the connection is OK, click the “Start Uploading” button to start software uploading. It will take several minutes to perform software update.
If the option “Incremental Update” is not checked, all processors will be updated (including processors with the same software version).
If you wish to update only processors with not topical versions of software, check the “Incremental Update box“.
Avoid interrupting the process. Update status is being displayed in the “Info Box” window.
When the update is finished, the line with the text “Fixture is successfully updated“ will appear in this window.
In case upload process is interrupted (e.g. power loss), the fixture stays in “Updating mode” and you will have to repeat the software update again.
Another way, how to update software in the fixtures (especially large installation of fixtures) is to use the ROBE Uploader. It is a software for automatized software update of ROBE fixtures.
For more information please see https://www.robe.cz/robe-uploader/.

RDM

This fixture is ready for RDM operation.RDM (Remote Device Management) is a bi-directional communications protocol for use in DMX512 control systems, it is the new open standard for DMX512 device configuration and status monitoring.
The RDM protocol allows data packets to be inserted into a DMX512 data stream without adversely affecting existing non-RDM equipment. By using a special „Start Code,“ and by complying with the timing specifications foDMX512, the RDM protocol allows a console or dedicated RDM controller to send commands to and receive messages from specific moving lights.
RDM allows explicit commands to be sent to a device and responses to be received from it.
The list of commands for ArcPower 24 Outdoor is the following.

Parameter ID| Discovery command| SET command|

GET command

---|---|---|---
DISC_UNIQUE_BRANCH| | |
DISC_MUTE|
| |
DISC_UN_MUTE| | |
DEVICE_INFO| | |

SUPPORTED_PARAMETERS| | |
SOFTWARE_VERSION_LABEL| | |

DMX_START_ADDRESS| | |
IDENTIFY_DEVICE| | |
DEVICE_MODEL_DESCRIPTION| | |
MANUFACTURER_LABEL| | |

DEVICE_LABEL| | |
SENSOR_DEFINITION| | |
SENSOR_VALUE| | |

DISPLAY_LEVEL| | |
DEVICE_RESET| | *| ***
DMX_PERSONALITY| |
|
DMX_PERSONALITY_DESCRIPTION| | |

STATUS_MESSAGES| | |
STATUS_ID_DESCRIPTION| | |

DEVICE_HOURS| | | *****

Please, see the Robe Universal Interface user manual for detail description of RDM operation.

Error messages

Temp Sen Error – Connected LED module does not include temperature sensor, but the option “ Temp Sen” is On. Set this option to Off (Personality Temp Sen).

Wireless DMX operation

The wireless version of the ArcPower 24 Outdoor (ArcPower 24 Outdoor /W) is equipped with the Lumen Radio CRMX module and antenna for receiving DMX signal. CRMX module operates on the 2.4 GHz band.

  1. Select wireless DMX input from the menu PErS (PErS–>dMX In–>Wireless). If the option “Wrle Out” is selected, the fixture receives wireless DMX and sends the signal to its wired DMX output.

  2. To link the fixture with DMX transmitter.
    The fixture can be only linked with the transmitter by running the link procedure at DMX transmitter .
    After linking , the level of DMX signal ( 0-100 %) is displayed in the menu Special (Special–>Wireless–>Stat).

  3. To unlink the fixture from DMX transmitter.
    The fixture can be unlinked from receiver via the menu Special (–>Wireless–>Unlink).

Technical specifications

Power supply

  • Electronic auto-ranging
  • Input voltage: 100 – 240V AC, 50-60 Hz
  • Max. power consumption: 70W (power factor=0.81, I=0.3A at 230V)

Light effects

  • RGBW colour mixing
  • Virtual colour wheel
  • Adjustable strobe sequences
  • White colour balance adjusting

Load

  • Max. output current: 350mA or 700 mA per colour (channel)
  • Max. load (only one option):
    6 x 10W RGBW multi-chip LEDs
    24 LEDs@ 700mA (max. 6 LEDs per colour)
    24 LEDs @ 350mA (max. 6 LEDs per colour)

Control

  • Protocol: USITT DMX 512, RDM
  • DMX modes: 4 (RGBW mode), 3 (SW mode), 2 (SC mode)
  • Operation modes: DMX, Stand-alone
  • Setting and addressing: Two-row LCD display & control buttons or via RDM
  • 3 user editable programs each up to 40 steps.

Wireless DMX/RDM module (for wireless DMX version only: ArcPower 24 Outdoor /W)

  • Compliance with USITT DMX-512 (1986 & 1990) and 512-A
  • Full DMX fidelity and frame integrity
  • Auto sensing of DMX frame rate and frame size
  •  <5ms DMX latency
  • Operational frequency range of 2402-2480 MHz
  • Producer: LumenRadio Antenna (for wireless DMX version only)
  • Max. gain: 5dBi

Strobe

  • Strobe effect with variable speed (max. 20 flashes per second)
  • Pre-programmed random strobe pulse-effects

Dimmer

  • Smooth 16-bit dimming from 0 – 100 %

Mounting

  • Via four mounting holes in the housing

Temperatures

  • Maximum ambient temperature: 40° C
  • Maximum housing temperature: 60° C

Total heat dissipation

  • 178 BTU/h (calculated)

Dimensions (mm)

Anolis ArcPower 24 Outdoor Wireless DMX - Featured
Image

Weight

  • 1.4 kg Protection factor
  • IP 67 (ArcPower 24 Outdoor CE, junction box)

Connection

  • Data/power cable: Li9Y11Y 3xAWG16+2xAVG24 shielded and jacketed
  • junction box
  • connection between ArcPower 24 Outdoor and LED unit: LiYY 8xAWG22 UL Style 2517/CSA O.D.
    6,70mm (lenght=0.6m) with connector CGRBDU-08BFFA (female)
    Note. max. length of connection cable between the ArPower 24 Outdoor and the LED unit should not exceed 20 metres (at 700mA load) or 80 metres (at 350mA load).

Included items

  • 1 x ArcPower 24 Outdoor
  • 1x connector Chogori 08BMMA-SL8001 (male)
  • 1 x Junction box (P/N 99714080)
  • 4 x reducing seal (P/N 13051388) – for diameter of cable 4-8mm
  • 1 x User manual

Cleaning and maintenance

DANGER !
Disconnect from the mains before starting any cleaning or maintenance work
Rinse off loose dirt with low pressure water spray. Wash the housing with a soft brush or sponge and a mild, nonabrasive washing detergent. Rinse it. There are no serviceable
parts inside the device.  Maintenance andservice operations are only to be carried out by a qualified person. Should you need any spare parts, please use genuine parts.
Specifications are subject to change without notice.
May 24, 2022
Made in CZECH REPUBLIC by ROBE LIGHTING s.r.o. Palackeho 416/20 CZ 75701 Valasske Mezirici

https://www.anolislighting.com/resource/arcpowertm-24-outdoor-user-manual- ce-

Documents / Resources

| Anolis ArcPower 24 Outdoor Wireless DMX [pdf] User Manual
ArcPower 24 Outdoor Wireless DMX, ArcPower 24, Outdoor Wireless DMX, Wireless DMX, DMX
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals