LEDALITE ID-7806 BoldPlay Suspended Light Instruction Manual
- June 9, 2024
- LEDALITE
Table of Contents
- System Overview
- Module Lengths
- Mount Spacing
- Row Configurations
- Sensor in Rows
- Occupancy Sensor Coverage
- Photosensor spatial response
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
- 8-B x 1/4″ screw (x1)
- 10-24 locking nut (x2)
- 10-24 9/16” bolt (x2)
- 8-B x 1/4″ screw (x1)
- 8-32 x 11/32 screw (x2)
Classified
Installation Instructions
ID 7806 BoldPlay Suspended LED
BoldPlay Suspended
Standalone or continuous run configurations
System Overview
These instructions review how to install BoldPlay suspended fixtures. BoldPlay
4ft and 8ft modules can be installed as individual standalone units, or they
can be joined together to create continuous runs. The graphic below shows the
components required to install a typical run of BoldPlay suspended fixtures.
**BoldPlay joint kit(s)***
- A/C mounting bracket (x1)
- Break apart joiner aligner (x1)
-
8-B x 1/4″ screw (x1)
- Gasket (x1)
-
10-24 locking nut (x2)
-
10-24 9/16” bolt (x2)
*NOTE: 1 kit required for each in-run joint.
**BoldPlay end kit(s)***
- Endcap (x1) (sculptedshown)
- A/C mounting bracket (x1)
-
8-B x 1/4″ screw (x1)
-
8-32 x 11/32 screw (x2)
*NOTE: 2 kits required for each run (one for each end).
TOOLS REQUIRED: Phillips screwdriver, 3/8” nut driver and flat or #2 Robertson screwdriver.
Module Lengths
BoldPlay suspended systems come in 4ft and 8ft modules. Overall module lengths
are shown below.
Module lengths do not include endcaps.
Endcaps
Add two endcaps to the length of each run.
Mount Spacing
For on-grid T-bar ceiling installations, mounts attach directly to Tee. For non-accessible ceilings and off-grid T-bar installations, the graphic below indicates mount spacing for typical row lengths. Mounting options are also available for a wide variety of other ceiling types. See Suspended Mounting Options document for more detailed information.
Row Configurations
The tables below indicate how 4ft and 8ft modules can be combined to create continuous rows of various lengths.
Nominal row length | 4ft module | 8ft module |
---|---|---|
4′ | 1 x | |
8′ | 1x | |
12′ | 1x | lx |
16″ | 2x | |
20′ | lx | 2x |
24′ | 3x | |
28′ | 1x | 3x |
32′ | 4x | |
36″ | 1x | 4x |
40′ | 5x | |
44′ | 1x | 5x |
48′ | 6″x | |
52′ | 1x | 6″x |
Nomina l row length | 4ft module | 8ft module |
--- | --- | --- |
56″ | 7x | |
6″0 | 1 x | 7x |
6″4 | 8x | |
6″8 | 1x | 8x |
72′ | 9x | |
76″ | 1x | 9x |
80′ | 10x | |
84′ | 1 x | 10x |
88′ | 11x | |
92′ | 1x | 11x |
96″ | 12x | |
100′ | 1x | 12x |
*Overall row lengths provided do not include endcaps. Add two endcaps to the overall length of each row.
ATTENTION: Install in accordance with national and local building and
electrical codes.
-
Prepare fixtures / installceiling mounting components
Arrange boxed fixtures on floor in specified mounting locations; remove fixtures from boxes. Install all ceiling mounting components and vertical aircraft cables using
separate installation instructions for Aircraft Cable Mounting (supplied).
NOTE: If conditions are dusty/dirty, recommended practice is to leave fixtures in their plastic bags. Cut small holes in the bag as needed to complete the following installation sequence, and then completely remove the bag from the fixture when conditions are clean. This prevents dust and dirt build-up on the fixtures. -
Install end-of-row aircraft cable brackets A. Hook A/C mounting bracket to endplate as shown.
Raise bracket until security tab is engaged.
B. Attach bracket to fixture using supplied fastener.
NOTE: When installing individual modules, and the first fixture of a row, complete step 2 on both ends of fixture. -
Suspend & level first fixtureWith 2 people, raise the first fixture to the ceiling. At each end of the module, insert aircraft cable through aircraft cable adjuster (located on A/C mount bracket).
The adjuster will automatically grip and hold the cable.
IMPORTANT: Do not force cable into adjuster. See instruction A (next page) for details.
Trim aircraft cable below adjuster as per instruction A (next page).
Level the fixture (see instruction B & C on next page). -
Complete electrical connections NON-POWER LOCATIONS: Cap all wires and tuck into wire cavity.
POWER LOCATIONS: Remove required 1/2″ round knockout(s). Insert power cord and apply strain relief below the socket saddle to secure cord. Remove installed
quick-wire connectors (if applicable) at power feed locationsand complete electrical connections using wire nuts (supplied by others). Tuck wires into wire cavity.
NOTE: Use smallest appropriate wire nuts. NOTE 2: Power feed connections can also be completed at joint locations. -
Install in-row mount brackets and insert joiner aligners For each additional fixture in the row, at the end furthest from the existing suspended fixture, attach A/C mounting bracket to fixture using supplied fasteners (see step 2). At the end closest to the existing suspended fixture, insert joiner aligners into crossplate (aligners will lock into place).
-
Suspend and joinadditional fixtures to create row With two people, raise second fixture to ceiling. At joint, insert joiner aligners through black gasket and into suspended fixture. At other end (opposite joint), insert aircraft cable through adjuster.
IMPORTANT: Do not attempt to join fixtures on floor. Instead, hang one fixture at a time and join modules at ceiling level. -
Complete electrical connections at joints Complete in-row electricalconnections.
NON-POWER LOCATIONS: Use supplied quick-wire connectors. Tuck wires into wire cavity.
POWER LOCATIONS: Remove installed quick-wire connectors and complete electrical connections using wire nuts (supplied by others). Tuck wires into wiring cavity. -
Secure joints SLIDE MODULES TOGETHER: Secure joint from above using supplied nut and bolt hardware.
Repeat STEPS 5-8 for each additional fixture in row. -
Install endcaps Attach end caps using supplied #8 screws.
IMPORTANT: Do not over-tighten endcap fasteners. Philips Ledalite recommends tightening fasteners by hand. When screwhead is flush with crossplate, turn an additional full turn. -
Install light guide Identify smooth side of the Light Guide and ensure it is installed smooth side DOWN. Install Light Guide panel into LED fixture after joining and wiring is complete. Ensure panel is seated correctly asshown above.
A. Aircraft cable adjustment
IMPORTANT: Do not force cable into adjuster.Toinsert cable into adjuster, follow the steps below.
-
CUT
If required, cut cable ends cleanly prior to inserting into adjuster. Recommended cutters: K.K. Porter cable cutter cat. No. 06”90TN or Klein all purpose shears cat. No. 1104. -
INSERT
Carefully insert cable into tapered end. If cable does not insert easily or becomes jammed during insertion, use the release tool to remove cable.
Trim end and repeat process. DO NOT BEND CABLE BELOW BOTTOM OF ADJUSTER. -
TEST
Once cable is inserted, apply a 25lb point load to each mount bracket to ensure all connections are secure.
NOTE: Ensure fixture is level end-to-end. Support fixture from below and
use supplied aircraft cable release tool to make fine height adjustments.
B. Level horizontally
LEVEL HORIZONTALLY (shown above): Loosen fasteners on bottom of adjuster
and level as required. Tighten fastener once fixture is in level position.
C. Level vertically
LEVEL VERTICALLY (shown above): Support fixture from below and use
supplied aircraft cable release tool to make fine height adjustments (see
instruction A for details).
This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interreference when
the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
For circuit sizing, refer to commissioned & uncommissioned ratings on product
power label / specification sheet.
Note: Tunable White luminaires must be commissioned with a Philips
Dynalite control system to enable tunablefunctionality.
Sensor in Rows
Single Sensor Controlling Whole Row
-
Purple & brown (or purple & grey/pink) control wires MUST be connected between fixtures.
Note :
– A maximum of 8 drivers can be wired to 8 sensors; confirm fixture driver count with factory.
– Only one sensor is allowed on a wired zone. (Sensors can be paired together wirelessly via a mobile app). Multiple Sensors Controlling Separates Zones in a Row -
Purple & brown (or purple & grey/pink) control wires MUST NOT be connected between zones.
Notes :
– A maximum of 8 drivers can be wired to one sensor; confirm fixture driver count with factory.
– Only one sensor is allowed on a wired zone. (Sensors can be paired together wirelessly via a mobile app).
Sensor Spacing
- For correct operation, sensor should be placed a minimum distance of 8ft apart.
- Wireless sensor should be placed no further than 40ft apart for good wireless signal connection.
Important Consideration When Using Sensor in a Row
- For fixtures with wireless sensors (CS, SB or RA options): DO NOT connect fixture purple and brown (or purple & grey/pink) control wires to an external dimming witch. Fixture mains wiring should not be connected to a circuit with an external on/off switch.
- For best aesthetic condition, place sensors at ends of row only so as not to break the continuous lens.
- For better occupancy coverage in longer rows, sensors may be placed mid run, but keep in mind this will break the continuous lens into discrete sections. Alternatively, remote sensors may be used, note the same wiring rules will apply.
Occupancy Sensor Coverage
Note: Longer dimension of detection area (Y1, Y2) is parallel to longer dimension of the luminaire.
Daylight Sensor
The light sensor measures the total amount of light in a circular field of
approximately 80% of the PIR detection area. The following aspects should be
observed during installation:
- Minimum distance from the window = 2ft (0.6m).
- Prevent light reflections from outside entering the sensor (for example sunlight reflection on a car hood) as this will lead to incorrect light regulation.
As a guideline the formula 0.72 X H can be used to calculate the minimum distance between the window and sensor whereby H is the height from the bottom of the window to the sensor.
Height | Minor movement | Major movement |
---|---|---|
h | X1 | Y1 |
2.4m(7.9ft) | 1.9 m (6.2 ft) | 2.9 m (9.5 ft) |
3 m (9.8ft) | 2.4 m (7.9 ft) | 3.6 m (11.8 ft) |
The detection area for the movement sensor can be roughly divided into two parts;
- Minor movements (person moving = 3ft/s or 0.9m/s).
- Major movements (person moving = 3ft/s or 0.9m/s).
Photosensor spatial response
©
2019 Signify Holding. All rights are reserved.
Reproduction in whole or part is prohibited without the written consent of
the copyright owner.
Phone: 604.888.6811
Web:ledalite.com/products
Revision C
June 21, 2022
Signify North America Corporation. 400 Crossing Blvd, Suite 600
Bridgewater, NJ 08807.
Telephone:855-486-2216
Signify Canada Ltd. 281 Hillmount Road, Markham, ON, Canada L6C 2S3.
Telephone:800-668-9008
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>