LEDALITE FloatPlane Suspended Instruction Manual

System Overview

These instructions review how to install FloatPlane suspended fixtures. 4ft, 6ft and 8ft modules can be installed as individual standalone units, or they can be joined together to create continuous runs. The graphics below show the components required to install a typical run of FloatPlane suspended fixtures. IMPORTANT: Read all instructions before beginning installation.

Module Lengths

FloatPlane suspended fixtures come in 4ft, 6ft and 8ft modules. Overall module lengths are shown below. Add 9/16″ for each EDGE endcap or 1″ for each CURVE endcap.

Tools Required:

  • Medium Flat blade Screwdriver
  • Medium Phillips Screwdriver
  • 3/8″ Nut driver

Mount Spacing

FloatPlane fixture modules are designed for exact on-grid mounting.

1 Arrange boxed fixture on floor in specified mounting location, remove fixtures from boxes. Install all ceiling mounting components and vertical aircraft cables using separate installation instruction for Aircraft Cable Mounting (supplied).

ADDITIONAL INFORMATION

Dustcover

Dustcovers for FloatPlane suspended fixtures can be installed as follows.

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interreference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Module Lengths
FloatPlane suspended fixtures come in 4ft, 6ft and 8ft modules. The assembly of Dustcovers on the different module lengths are shown below.

ATTENTION: Install in accordance with national and local building and electrical codes.

Sensor in Rows
Important Consideration When Using Sensor in a Row

  • For fixtures with wireless sensors (CS, SB or RA options): DO NOT connect fixture purple and brown (or purple & grey/ pink) control wires to an external dimming switch. Fixture mains wiring should not be connected to a circuit with an external on/off switch.
  • For best aesthetic condition, place sensors at ends of row only so as not to break the continuous lens.
  • For better occupancy coverage in longer rows, sensors may be placed mid run, but keep in mind this will break the continuous lens into discrete sections. Alternatively, remote sensors may be used, note the same wiring rules will apply.

Occupancy Sensor Coverage:
Note: Longer dimension of detection area (Y1, Y2) is parallel to longer dimension of the luminaire.

Daylight Sensor
The light sensor measures the total amount of light in a circular field of approximately 80% of the PIR detection area. The following aspects should be observed during installation:

  • Minimum distance from the window 2ft (0.6m).
  • Prevent light reflections from outside entering the sensor (for example sunlight reflection on a car hood) as this will lead to incorrect light regulation.

As a guideline the formula 0.72 X H can be used to calculate the minimum distance between the window and sensor whereby H is the height from the bottom of the window to the sensor.

The detection area for the movement sensor can be roughly divided into two parts;

  • Minor movements (person moving 3ft/s or 0.9m/s).
  • Major movements (person moving 3ft/s or 0.9m/s).

Photosensor spatial response

ℹ ATTENTION: Install in accordance with national and local building and electrical codes.

© 2019 Signify Holding. All rights are reserved. Reproduction in whole or part is prohibited without the written consent of the copyright owner. Phone: 604.888.6811 Web: ledalite.com/products Revision E lune 20. 2022

Signify North America Corporation. 400 Crossing Blvd, Suite 600 Bridgewater, NJ 08807. Telephone: 855-486,2216 Signify Canada Ltd. 281 Hillmount Road, Markham, ON, Canada L6C 2S3. Telephone: 800,668·9008

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals