Installation

GE-93130503-Cync-Pro-Pack-15-Amp-Singl-pole-3-way-Smart-
Illuminated-Touch-Light-Switch-fig-11

Compatibilify Requiremenfs

  • Rating 120V AC 60 HZ
  • Neutral wire is required (wire is usually white or grey)
  • Ground wire is required (wire is usually green, green with a yellow stripe, or copper)
  • Wi-Fi 802.11 b/g/n @ 24 GHz is required
  • Works with compatible LED bulbs, including CYNC and C by GE smart LED bulbs. Visit cyncsupportgelighting.com

Maximum load

  • LED up to 150 watts
  • Incandescent/halogen up to 450 watts

IMPORTANT NOTE ON 3-WAY WIRING:

  • Some lights have one wall switch, while others are controlled by two or more wall switches (such as stair lights, which have a switch at both the top and bottom of the stairs). If your lights have more than one switch (called a 3-way), we’ve created instructions for how to install and enable the capability.
  • Visit cyncsupportgelighting.com for 3-way installation instructions and how-to-videos.
  • FOR SET UP HELP, VIsIT CYNCSUPPORT.GELIGHTING.COM OR CALL 1-844-302-2943.

STEP 1 TURN OFF THE POWER

  • Turn off the power for the switch location at the circuit breaker box.
  • Test existing switch by foggling switch on/oft, ensuring lights do not furn on.
  • Now, follow these setup steps for a single gang switch.GE-93130503-Cync-Pro-Pack-15-Amp-Singl-pole-3-way-Smart-Illuminated-Touch-Light-Switch-fig-1

STEP 2 REMOVE YOUR OLD SWITCH

  1. Remove the existing wall plate and switch from the wal.

  2. Use voltage tester on the black wires to confirm power to the switch is off (recommended).

  3. Before disconnecting fhe wires from fhe wal, label each wire.
    Neutral and ground wires are required. If you don’t have either wire, the smart switch is nof compafible.

  4. Disconnect wires and remove existing switch.GE-93130503-Cync-Pro-Pack-15-Amp-Singl-pole-3-way-Smart-Illuminated-Touch-Light-Switch-fig-2

STEP 3 cONNECT THE WIRESGE-93130503-Cync-Pro-Pack-15-Amp-Singl-pole-3
-way-Smart-Illuminated-Touch-Light-Switch-fig-3

  1. Connect the neutral (white) wire on the switch to the neutral (white) wire from the wall.
  2. Connect the line (black) wire on the switch to the line (black labe) wire from the wall.
  3. Connect the load (red) wire on the switch with the load (red label) wire from the wall
  4. Connect the ground green) wire on the switch with the ground green) wire from the wal.
  5. Cap the 3-way/multi-way traveler wire (f applicable). For 3-way switch setup, visit cyncsupportgelighting.com
    Attention: Incorrectly connecting the Neutral or Ground wire from the wall to the Line or Load wire on the switch will damage the product.

Congratulations

  • You’ve completed the Smart Switch installation.

Enable Your Voice Assistant

  • Easily connect your Smart Switch to your Amazon Alexa- or

  • Hey Google-enabled device in the Cync App

AMAZON ALEXA TRY THIS..

  • Alexa, turn off the living room.

  • Alexa, turn on the bedroom.

  • Alexa, set kitchen to 50%.

HEY GOOGLE TRY THIS.

  • Hey Google, turn on the lights.

  • Hey Google, good morning.

  • Hey Google, I’m leaving.

BEFORE YOU BEGIN

Read these instructions completely and carefully.

WARNING: RISK OF ELECTRIC SHOCK

  • This product installation requires handling 120 volf wiring. Follow each step carefully.
  • If any concerns handling wiring, hire a qualihed electrician. Ensure all work meets local and federal regulations.

PACKAGE CONTENTS

GE-93130503-Cync-Pro-Pack-15-Amp-Singl-pole-3-way-
Smart-Illuminated-Touch-Light-Switch-fig-5

TOOLS REQUIRED

GE-93130503-Cync-Pro-Pack-15-Amp-Singl-pole-3-way-Smart-
Illuminated-Touch-Light-Switch-fig-6

STEP 4 FIT WIRES INTO WALL BOX

Neatly push the wires back into the box, rotating the switch SO ir’s oriented according fo the image.

STEP 5 SECURE THE SWITCH

  1. Using a Phillips screwdriver and provided screws, secure the switch to the wall until level and flushGE-93130503-Cync-Pro-Pack-15-Amp-Singl-pole-3-way-Smart-Illuminated-Touch-Light-Switch-fig-7
  2. Screw on a standard paddle-style wall plate (not included).GE-93130503-Cync-Pro-Pack-15-Amp-Singl-pole-3-way-Smart-Illuminated-Touch-Light-Switch-fig-8

STEP 6 TURN THE POWER BACK ONGE-93130503-Cync-Pro-Pack-15-Amp-Singl-
pole-3-way-Smart-Illuminated-Touch-Light-Switch-fig-9

  1. After the switch is secured and faceplate mounted, turn the power back on at the circuit breaker box.
  2. At the switch, the light ring indicator will flash blue indicating the device is wired correctly and is in setup mode.
  3. Light ring will flash blue until the switch is added to the Cync ApP.
  4. Light ring will flash red when WI-Fi is disconnected.
  5. Light ring will not illuminate if wired incorrectly.

IF LIGHTs DON’T TURN ON:

  1. Check that air gap switch is depressed.
  2. Check that power to the switch is on at the breaker.
  3. Turn power off at the breaker, refurn to the switch to confirm the wires are securely and properly wired according to the installation guide.
  4. Go to cyncsupportgelighting.com for more troubleshooting.

Additional Information and Warnings

FCC Compliance Statement Compliance Notice
This equipmenf has been fested and found to comply with the limts for a Class B digifal device, pursuant fo part of he Fuc Rules. Ihese limirs are designed to provide redsondble protection against harmTul interterence in a residenfial installafion. Ihis equipment generates, USes and can radiate radio frequencyY energy and, if nof insfalled and used in accordance with the instructions, may cause harmful inferference fo radio communications. However, there is no guarantee that interference will nof occur in parficularinstallation. Ilf his equipment does cause harmtul interterence to radio or felevision reception, which can be determined by furning the equipment of and on, the user is encouraged to fry fo correct the inferference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.
  • This device compies with part 15 of FCC rules. Operation is subject fo the following fwo conditions:
  1.  This device may not cause harmful interference
  2.  This device must accept any inferference received, including interference that may cause undesired operation.
  3. Changes or modifcafions that are not expressly approved by the manufacfurer could void the user’s aurhority fo operare the equipment.

RF Exposure Informafion:

  • This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.
  • In order fo avoid the possiblity of exceeding the FCC radio frequency exposUre limifs, human proximity fo
  • The antenna shdll nor be less nan8 inches during normal operarion.

RF Exposure Statement:

  • This equipment complies with IC RSS-102 radiation exposure limits set forth for an uncontrolled environment. This transmitter must be installed to provide a separation distance of at least 8 inches from all persons and must not be collocated or operafing in conjuncfion with any ofher anfenna or fransmiffer.
  • CAUTION – To reduce the risk of overheating and possible damage to other equipment, do not install to control a receptacle or motor-operated appliance or transformer-supplied appliance.

For supply connections, use copper wire only rated at 75°C.

  • GE Lighting, a Savant company 1-844-302-2943 gelighting.com/cync
  • GE AND C BY GE ARE TRADEMARKS OF GENERAL ELECTRIC COMPANY. USED UNDER TRADEMARK LICENSE.
  • ©2022 GE LIGHTING, A SAVANT COMPANY INFORMATION PROVIDED IS SUBJECT TO CHANGE WITHOUT NOTICE. ALL VALUES ARE DESIGN OR TYPICAL VALUES WHEN MEASURED UNDER LABORATORY CONDITIONS.

Documents / Resources

| GE 93130503 Cync Pro Pack 1.5-Amp Single-pole/3-way Smart Illuminated Touch Light Switch [pdf] Instruction Manual
93130503 Cync Pro Pack 1.5-Amp Single-pole 3-way Smart Illuminated Touch Light Switch, 93130503, Cync Pro Pack 1.5-Amp Single-pole 3-way Smart Illuminated Touch Light Switch, Smart Illuminated Touch Light Switch, Touch Light Switch
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

GE User Manuals

Related Manuals