GE current IND619 LED Emergency Lighting Fixture Instructions
- October 27, 2023
- GE current
Table of Contents
Instructions for LED Emergency Lighting Fixture
Instructions
IND619 LED Emergency Lighting Fixture
IMPORTANT :
Let the battery charge up for at least 24 hours. Then the normal operation of
this unit should take effect. To check, press the ” TEST ” button. The LED
lamps on the unit should turn ON. During an electrical power failure, the led
lamps will automatically come on for a minimum of 90 minutes. In accordance
with NFPA 101, your emergency lighting system must be tested monthly for a
minimum of 30 seconds and annually for 90 minutes. Refer to your local codes
for any additional requirements that may apply.
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions should always be
followed including the following:
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
- Do not use outdoors.
- Equipment should be mounted in locations and at heights where it will not be subject to tampering by unauthorized personnel.
- Do not mount near gas or electric heaters.
- The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition.
- Do not use this equipment for anything other than its intended use.
- Servicing of this equipment should be performed by qualified personnel.
- Disconnect AC power before servicing.
SAVE THESE INSTRUCTIONS
FLEXIBLE CONDUIT ONLY
INSTALLATION (J-BOX MOUNTING)
- The feed fixture leads through the back plate and connects to the AC power supply (Fig A). For 120V use black and white wires and for 277V, use red and white wires.
- Attach the back plate to J-Box and secure it with screws.
- Complete the battery connection. (Fig. B)
- Align snaps and push housing directly onto the back plate (Fig. C). Apply continuous AC power and press the “TEST” button to check the light.
INSTALLATION (CONDUIT )
- Secure the back plate to the wall surface. Route wires through holes in the conduit flange and makes a conduit connection. For 120V, use black and white wires and for 277V, use red and white wires.
- Complete the battery connection (Fig. B).
- Align snaps and push housing directly onto the back plate (Fig. C). Apply continuous AC power and press the “TEST” button to check the light.
WARNING:
Unused wires must be capped using enclosed wire nuts.
OPERATION
- During an electrical power failure, the LED lamps will automatically come on for a minimum of 90 minutes.
- To test, depress the “TEST” switch. The emergency LED lamps will illuminate. When the switch is released, the lamps will go off.
WIRING DIAGRAM
Note:
Use 18-22 AWG stranded wire to connect remote lamp heads.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>