Kwikset 98880-004 SMARTCODE Keypad Electronic Locks User Guide

June 3, 2024
Kwikset

Kwikset 98880-004 SMARTCODE Keypad Electronic Locks

Welcome to the Kwikset family!
This guide will get you up and running with your new SmartCode™ Lock.

Parts in the box

  • Exterior assembly
    Exterior assembly

  • Interior assembly

  • Interior cover


Parts in the box
Parts in the box
Parts in the box

Required tools

Philips screwdriver

No electric drills

Installation

Remove your existing deadbolt and strike

| If drilling a new door, use the supplied template and instructions available at: kwikset.com/doorprep
---|---

Install the latch

[OUTSIDE]

*Use the longer screws if the holes are worn out. You will have two extra screws.

If your door is not chiseled, install the drive-in collar .

Install the latch

Install the strike

Install the strike

Install the exterior assembly

Install the exterior assembly

Route the cable through the center hole of the mounting plate.
Install the exterior assembly

Push the cable into the bottom hole of the mounting plate.
Install the exterior assembly

Insert the key and test the latch. If the latch does not extend or retract smoothly, adjust the screws. Leave bolt LOCKED/EXTENDED.
Install the exterior assembly

  Install the interior assembly

Check to make sure the latch bolt is in the extended/locked position to install the interior assembly

If the turnpiece is not pointing up, rotate the turnpiece until you hear a click.
Install the interior assembly

Remove the interior cover from the interior assembly
Install the interior assembly

Secure the interior assembly onto the mounting plate.

Connect the cable. Ensure a tight cable connection
Install the interior assembly

Route cable around the side notch and bottom of the interior assembly.
Install the interior assembly

Insert the flat blade into the turnpiece shaft.
Install the interior assembly

Install the AA batteries

Ensure the door is open while installing batteries.

Add a User Code and install cover

Add a User Code per instructions on page 19.
After the first User Code is created, the latch bolt will automatically retract and extend to learn the locking and unlocking direction of the door.

Secure the interior cover onto the interior assembly.

Bolt will extend and retract to learn the orientation of the door. Keypad will indicate success or failure.
Green : Door handing was successful.
Red : Door handing was unsuccessful.
Make sure the interior and batteries are correctly installed.

Before you can lock or unlock the door a User Code must be created. Refer to page 19 for instructions on how to create a User Code

Locking

To lock your door, press the Lock button. The lock will beep and the keypad will flash amber as the bolt extends.

Locking

Unlocking

To unlock your door, enter the User Code. The lock will beep and the keypad will flash green and beep twice as the bolt retracts.

Unlocking

SmartCode™ at a Glance

  1. Lock Button
    Used for programming, clearing User Code entry errors, lighting up the keypad and locking the door.

  2. Number Buttons
    Used to enter User Codes. Each code must be 4 to 8 digits in length.

  3. SmartKey Cylinder
    Rekeyable cylinder retracts and extends the latch bolt by key from the exterior.
    SmartCode™ at a Glance

  4. Battery Holder
    Uses 4 AA Alkaline batteries, 1.5V

  5. Programming Button
    Used for programming functions.

  6. Turnpiece
    Lock and unlock from the interior.

  7. Battery Cover
    Push it upward and outward to replace the batteries.
    SmartCode™ at a Glance

SmartKey Re-Keying

Re-key the lock to work with your existing key. See the supplied SmartKey Re- key instructions for more information.
Note : If Auto-Lock is enabled, remove the batteries before re-keying your lock.

SmartKey Re-Keying

System Alerts

Operation Lights Sounds Explanation Troubleshoot
Unlock Flashes GREEN x2 2 beeps Successful unlock
Flashes RED x10 10 beeps Low battery Install fresh new batteries
Flashes RED x 3 3 beeps Incorrect User Code Check code, and retry
Flashes RED x15 15 beeps Exceed 3 incorrect User Code attempts Wait 1

minute, check code, and retry
Lock| Flashes AMBER x2| 2 beeps| Successful lock|
Flashes RED x10| 10 beeps| Low battery| Install fresh new batteries
Alternate RED/ WHITE Flash x5| 5 beeps| Stuck/Jammed bolt| Clear jam and try again
Factory Reset| Flashes GREEN x1| 1 beep| Successful|
Flashes RED x3| 3 beeps| Unsuccessful| Retry factory reset steps. Make sure to press the Programming Button one more time within 10 seconds after the long beep.
Programming| Flashes GREEN x1| 1 beep| Successful|
Flashes RED x3| 3 beeps| Unsuccessful| Review Programming steps

Programming

Ensure the door is open before performing any programming. The programming button is located on the interior chassis below the battery holder (refer to page 17). During programming, if no button is pressed within 5 seconds, the system will time out and you will need to restart the procedure.

Add User Code (UC)| Programming Button

enter UC

---|---
Delete Individual User Codes (UC)| Programming Button enter UC to delete enter UC to delete
Add/Change Programming Code (PC)| Programming Button enter PC
Delete all User Codes| Programming Button
Enable/Disable Audio| Programming Button
Enable/Disable User Codes| Programming Button
Add One-time User Code| Programming Button enter one-time UC
Change Auto-Lock Time Delay| Programming Button     press button for delay
30 seconds 1 minute 3 minutes 5 minutes 10 minutes
Enable/Disable Auto-Lock| Programming Button
Door Rehanding| Programming Button
Factory Reset (lock must be in unlocked position)| Press and HOLD Programming Button for 15 seconds Programming Button again

Programming Notes

Add User Code:
Up to 50 User Codes can be saved. User Codes should be 4 to 8 digits in length. For security reasons, the first 4 digits of each User Code must be unique. For example, you are unable to program a User Code 1-2-3-4-5 as well as a User Code 1-2-3-4-6.
Press the lock button before entering your code to light up the keypad at night.

Enable/Disable Programming Code:
Optional: A Programming Code enables you to make programming changes without needing to access the programming button. This is ideal for landlords to allow programming from the outside without access to the interior programming button. One Programming Code can be saved and should be 4 to 8 digits in length. The Programming Code can not be the same as any User Code and will not unlock the lock.

To program the lock when the Programming Code is enabled, instead of pressing the programming button, enter the Programming Code, press the lock button and proceed with the remaining steps on page 19. Repeat the programming steps to disable the Programming Code. Please note once a Programing Code is enabled, the programming button is disabled and can only be used to factory reset the lock.

Delete All User Codes:
Keypad locking function will be disabled when User Codes are deleted. The lock can only be operated manually by key during this time.

Enable/Disable Audio:
LED status indicator will still function once audio is disabled. Repeat the programming steps to enable the audio.

Enable/Disable User Codes:
When all User Codes are disabled, all electronic functions will be disabled as well. The door must be locked or unlocked manually with the key. Repeat the programming steps to enable the User Codes.

Add One-Time Use Code:
Up to 10 One-time User Codes can be saved. One-time User Codes should be 4 to 8 digits in length. The One-Time User Code will be deleted automatically after it is used. The same One-Time User Code can be created again after it’s used.

Change Auto-Lock Time Delay:
Press the keypad number that corresponds to your time delay preference:
“1”: 30 seconds “2”: 1 minute “3”: 3 minutes “4”: 5 minutes “5”: 10 minutes

Enable/Disable AutoLock:
The default setting is disabled. Once you enable auto-lock the default setting is set to 30 seconds. To change the auto lock time delay, see the “Change Auto-Lock Time Delay” programming step. Repeat the programming steps to disable auto-lock.

Door Rehanding Identification:
Perform this process for the lock to learn the locking and unlocking direction of the door. This feature is used for the lock to learn the orientation of your door (left- or righthanded). If stuck/jammed bolt error continues to occur after performing this step, please make sure there is no obstruction from strike or door jamb to prevent the bolt from extending.

Factory Reset:
A factory reset will delete all User Codes and change all programming to factory settings.

Important Safeguards

  1. Read all instructions in their entirety.
  2. Familiarize yourself with all warning and caution statements.
  3. Remind all family members of safety precautions.
  4. Always have access to your lock’s standard key.
  5. If using the Auto-Lock features, make sure you have your smartphone or standard key with you to prevent locking yourself out.
  6. Familiarize yourself with the system alerts.
  7. Replace low batteries immediately.
  8. Dispose of used batteries according to local laws and regulations.

WARNING : This Manufacturer advises that no lock can provide complete security by itself. This lock may be defeated by forcible or technical means, or evaded by entry elsewhere on the property. No lock can substitute for caution, awareness of your environment, and common sense. Builder’s hardware is available in multiple performance grades to suit the application. In order to enhance security and reduce risk, you should consult a qualified locksmith or other security professional.

CAUTION : Prevent unauthorized entry. Since anyone with access to the back panel can change the User Codes, you must restrict access to the back panel and routinely check the User Codes to ensure they have not been altered without your knowledge. The use of a programming code can help protect your system’s settings.

Regulatory Compliance

This product complies with standards established by the following regulatory bodies:

  • Federal Communications Commission (FCC)
  • Industry Canada

FCC
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
( 1 ) this device may not cause harmful interference, and ( 2 ) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

IMPORTANT! Changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment.

Industry Canada

This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions: ( 1 ) This device may not cause interference, and( 2 ) This device must accept any interference, including interference that may cause undesired operation of the device.

BEFORE YOU BEGIN| |
---|---|---
Bilt|
Scan for easy 3D instructions
Download the BILT app before you begin|

Customer Support

If you have any issues, please visit our support center: kwikset.com or call us at 1-800-327-5625.

Kwikset

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals