Strand 63025 RS232 Serial Interface User Guide

June 3, 2024
Strand

Strand 63025 RS232 Serial Interface

This document provides basic setup instructions and safety warnings for the following product(s):

INSTALLATION

The Vision.Net Network consists of a single CAT5e cable connecting all modules in a daisy chain manner. All units connect to the network using a 9-pin plug- in connector (included).

To install the RS232 serial port interface:

  • Step 1. Unpack unit and inspect for any signs of shipping damage. Ensure that two mounting screws are included.

  • Step 2. Connect Vision.Net Network Cable to 9-pin connector at back of RS232 Interface.
    PIN NO.| SIGNAL| WIRE COLOR
    ---|---|---
    1| DATA +| White / Orange
    2| DATA –| Orange
    3| No Connection| N/A
    4| +NET V| White / Green
    5| Ground| Green
    6| + NET V| White / Blue
    7| Ground| Blue
    8| + NET V| White / Brown
    9| Ground| Brown

  • Step 3. Insert RS232 Interface into standard deep rough-in box (not included). Secure with two supplied mounting screws.

  • Step 4. Snap faceplate into place.
    NOTE: A standard IBM-compatible computer can be connected to the Vision.Net Network using the RS232 Interface. The port accepts a standard one- to-one 9-pin serial cable up to 25 feet (7.5 meters) in length.

OPERATION

The RS232 Serial Interface Port operates in one of two modes: Vision.net (binary) or Show Control (ASCII).

VISION.NET MODE SHOW CONTROL MODE
8-Bit 8 Bit
1-Stop Bit 1 Stop Bit
19200 Baud 9600 Baud
Protocol: Binary Protocol: ASCII

The unit will sense the incoming protocol and automatically switch to the proper mode.
Note: It may take several messages from either the third-party system or the Vision.net Designer PC before the RS232 Interface switches modes.

COMMUNICATIONS

These are the communication protocols available for use with the RS232 Serial Port Interface.

  • Vision.Net Protocol (binary)
  • ASCII
    DESIGNER COMMANDS| ASCII RS232| NOTES
    ---|---|---
    Print Command Help Page| HH|
    Start Preset| SP rrr pp tt| rrr = Room (1 – 255), pp = Preset (1-32, 0 = Off), tt Rate Index (see “Rate Index” on page 47)
    Toggle Down| TD rrr ccc| ****

rrr = Room (1 – 255), ccc = Channel (1 – 127)

Toggle Up| TU rrr ccc
Learn Preset| LP rrr pp| rrr = Room (1 – 255), pp = Preset (1-32, 0 = Off)
Slider Level| SL rrr ccc lll| rrr = Room (1 – 255), ccc = Channel (1 – 127), lll = Level (0 – 255)
Learn Submaster| LS rrr ss| rrr = Room (1 – 255), ss = Submaster Index (1 – 16)

rrr = Room (1 – 255), ggg = Grand Master Level (0 – 255)x, lll = Level (0 – 255)

Manual| MN rrr ggg lll … lll
Expander Group| EG rrr ee ff lll … lll| rrr = Room (1 – 255), ee = Expander Group (0 – 15), ff = Index of First Channel, lll = Level (0 – 255)
Start Raise| RA rrr qqq| rrr = Room (1 – 255), qqq = Coded Channel (0: Reserved, 1- 127:

Channels 1 to 127, 128: All Channels in Room, 129 – 255: Channel

in Preset 1 – 126, 255: Current Preset Channels)

Note: Sending a second after a RA or LW command will

Start Lower| LW rrr qqq
Stop Raise/Lower| ST rrr qqq
Record Blind| RB rrr pp ggg lll … lll| rrr = Room (1 – 255), pp = Preset (1-32, 0 = Off), ggg = Grand Master Level (0 – 255), lll = Level (0 – 255)
Lock Button| LB idd n| ****


idd = __ , n = Button/LED (1-255)

Unlock Button| UB idd n
Smart On| SN idd n
Smart Off| SF idd n
Define Room Link| DR x fff rrr … rrr| x = Links (0: Clear All Links / 1: Do Not Clear), fff = First Room (1-255), rrr = Room (1 – 255)
Submaster Level| SB rrr ss lll| rrr = Room (1 – 255), ss = Submaster Index (1-16), lll = Level (0 – 255)
Take Control (sub)| TC rrr ggg lll … lll| rrr = Room (1 – 255), ggg = Grand Master Level (0 – 255), lll = Level (0

– 255)

Set Channel| SC rrr ccc lll tt| rrr = Room (1 – 255), ccc = Channel (1 – 127), lll = Level (0 – 255), tt = Rate Index (see “Rate Index” on page 47)
Set Mode| SM mm| mm = Mode (0 = All Modes)
Send Mimic| MC idd n a| idd = __ , n = Button/LED (1-255), a = Action (0/1= Off/On or

Button Up/Down for Send Mimic Command)

(0/1= Button Down/Up for Console Button Command) (0/1= LED Off/ On for Console LED Command)

Console Button| CB idd n a
Console LED| CL idd n a
VALUE| MEANING
---|---
0| Instant
1| 1 second
2| 2 seconds
3| 3 seconds
4| 5 seconds
5| 7 seconds
6| 10 seconds
7| 15 seconds
8| 30 seconds
9| 1 minute
10| 5 minutes
11| 15 minutes
12| 30 minutes
13| 60 minute

IMPORTANT INFORMATION

WARNINGS AND NOTICES
When using electrical equipment, basic safety precautions should always be followed including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS.

  • For indoor, dry locations use only. Do not use outdoors.

  • Do not mount near gas or electric heaters.

  • Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel.

  • The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition.

  • Not for residential use. Do not use this equipment for other than intended use.

  • Refer service to qualifi ed personnel.
    SAVE THESE INSTRUCTIONS.

  • WARNING: You must have access to a main circuit breaker or other power disconnect device before installing any wiring. Be sure that power is disconnected by removing fuses or turning the main circuit breaker off before installation. Installing the device with power on may expose you to dangerous voltages and damage the device. A qualifi ed electrician must perform this installation.

  • WARNING: Refer to National Electrical Code® and local codes for cable specifi cations. Failure to use proper cable can result in damage to equipment or danger to personnel.

  • WARNING: This equipment is intended for installation in accordance with the National Electric Code® and local regulations. It is also intended for installation in indoor applications only. Before any electrical work is performed, disconnect power at the circuit breaker or remove the fuse to avoid shock or damage to the control. It is recommended that a qualifi ed electrician perform this installation.

CUSTOMER SERVICE

If you have any questions regarding this product, please contact Customer Service at +1-214-647-7880 or via e-mail at entertainment.service@signify.

LIMITED 2-YEAR WARRANTY

Strand offers a two-year limited warranty on its control products against defects in materials or workmanship from the date of delivery. A copy of Strand two-year limited warranty containing specifi c terms and conditions can be obtained from the Strand website at www.strandlighting.com or by contacting your local Strand office.

STRAND OFFICES

  • AMERICAS
    10911 Petal Street Dallas, TX 75235 Tel: +1 214-647-7880 Fax: +1 214-647-8039

  • ASIA
    Room 1201, Freetown Tower D E 3rd Ring Rd S, 58 Chaoyang Qu Beijing Shi, China
    Tel: +8610-58674776
    Fax: +8610-58674775
    B-1-27, Dataran Cascades, No. 13A Jalan PJU 5/1 Kota Damansara PJU 5 47810 Petaling Jaya Selangor, Malaysia
    Tel: +60 3-7611 7302

  • EUROPE
    Rondweg Zuid 85 Winterswijk 7102 JD Netherlands
    Tel: +31 543-542516 Fax: +31 543-542513
    24 Sovereign Park Coronation Road Park Royal, London NW10 7QP United Kingdom Tel: +44 020 8965 3209

© 2019 Signify Holding. All rights reserved.
All trademarks are owned by Signify Holding or their respective owners. The information provided herein is subject to change, without notice. Signify does not give any representation or warranty as to the accuracy or completeness of the information included herein and shall not be liable for any action in reliance thereon. The information presented in this document is not intended as any commercial offer and does not form part of any quotation or contract, unless otherwise agreed by Signify. Data subject to change.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals