This document provides basic setup instructions and safety warnings for the following product(s):
Acclaim Led Fresnel (black body) 54108-020 912400576885
Acclaim Led Fresnel (white body) 54109-020 912400576886
INCLUDED ITEMS
Acclaim Led Fresnel|
---|---
Quick start guide|
Power connector|
Warranty card|
INSTALLATION AND SETUP
MOUNTING
The unit should be mounted via its screw holes on the bracket. Always
ensure that the unit is firmly fixed to avoid vibration and slipping while
operating. Always ensure that the structure to which you are attaching the
unit is secure and is able to support a weight of 10 times the unit’s weight.
Always use a safety cable that can hold up to 12 times the weight of the unit
when installing the fixture. The luminaire must be mounted by professionals.
SET UP
-
Lcd display – shows the menu and selected function
-
Buttons:
MENU – to select programming functions
DOWN – to go forward in selected functions
UP to go backward in selected functions
ENTER – to confirm the selected function -
POWER IN – connects to the power supply
-
POWER OUT – connects to next fixture
-
DMXOIN – 5-pin XLr cable to link the DMX console
-
DMX OUT – 5-pin XLR cable to link next fixture
QUICK REFERENCE DMX MAPS
8-BIT CHANNEL MODE
DMX CHANNEL | PARAMETER |
---|---|
1 | intensity (16-bit high) |
2 | Strobe |
3 | red (16-bit high) |
4 | Green (16-bit high) |
5 | Blue (16-bit high) |
6 | Lime (16-bit high) |
16-BIT CHANNEL MODE
DMX CHANNEL | PARAMETER |
---|---|
1 | intensity (16-bit high) |
2 | intensity (16-bit low) |
3 | Strobe |
4 | red (16-bit high) |
5 | red (16-bit low) |
6 | Green (16-bit high) |
7 | Green (16-bit low) |
8 | Blue (16-bit high) |
9 | Blue (16-bit low) |
10 | Lime (16-bit high) |
11 | Lime (16-bit low) |
ACClAIM LED FRESNEL
COMPLIANCE
This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when this equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with Vari-Lite system, service, and safety guidelines, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his/ her own expense.
DECLARATION OF CONFORMITY
We declare, under our sole responsibility, that this product complies with
the relevant clauses of the following standards and harmonized documents:
SAFETY
EN 60598-2-17;
EN 60598-1;
EN 62493;
EN 62031;
UL 1573 C22.2 No.166
EMC| EN 61000-3-2;
EN 61000-3-3;
EN 61547;
EN IEC 55015;
BS EN IEC 61000-3-2;
BS EN 61000-3-3;| BS EN 61547;
BS EN IEC 55015;
CISPR 15;
ICES-005
CFR47 FCC Part 15
Class B
---|---|---
CUSTOMER SERVICE
If you have any questions regarding this product, please contact Customer
Service at+1-214-647-7880 or via e-mail
at entertainment. service@signify.
LIMITED 2-YEAR WARRANTY
Vari-Lite offers a two-year limited warranty on its control products against
defects in materials or workmanship from the date of delivery. A copy of Vari-
Lite two-year limited warranty containing specific terms and conditions can be
obtained from the Vari-Lite website at www. strandlighting.com or by
contacting your local Vari-Lite office.
SAFETY WARNINGS AND NOTICES
When using electrical equipment, basic safety precautions should always be
followed including the following:
READ AND FOLLOW ALL SAFETY INSTRUCTIONS.
- For indoor, dry locations use only. Do not use outdoors.
- Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel.
- The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition.
- Not for residential use. Do not use this equipment other than intended use.
- Refer service to qualified personnel. This fixture contains no user-serviceable parts.
- Prior to first use, carefully inspect the unit for damage from shipping.
- Installation and operation to be performed by qualified personnel only.
- Use a safety tether when mounting.
- Install only in locations with adequate ventilation of at least 50cm clearance from adjacent surfaces.
- Ensure sure that ventilation slots are not blocked.
- Ensure that the voltage and frequency of the power supply match the power requirements of the fixture.
- The fixture must be earthed/grounded to the appropriate conductor
- Do not operate fixtures outside the ambient temperature range of -1040°C.
- Do not connect the fixture to any dimmer pack.
- New fixtures may emit a chemical odor due to the manufacturing process. This odor will dissipate over time.
- Note distance requirement(s) from combustible materials or illuminated objects. Do not mount near gas or electric heaters.
- Prior to each use, carefully inspect power cables and replace any damaged cables.
- Exterior surfaces of the luminaire will be hot during operation. Take appropriate precautions.
- Continuous use of the fixture may shorten the lifespan. Power down the fixture when not in use.
- Clean fixtures regularly, particularly when working in a dusty environment.
- Never touch power cables or wires while the fixture is powered on.
- Avoid entangling power wires with other cables.
- In the event of a serious operating problem, immediately discontinue using the fixture.
- Never turn on and off the unit time after time.
- The housing, lenses, and/or the ultraviolet filter must be replaced if they are damaged.
- Disconnect mains power if the fixture is not used for a long time.
- Original packing materials can be reused for transporting the fixture.
- This fixture is designed for dry locations only. Exposure to rain or moisture may damage the fixture unless it is suitably IP rated.
- Do not look directly at the LED light beam while the fixture is on.
- Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel.
SAVE THESE INSTRUCTIONS.
WARNING: Refer to National Electrical Code® and local codes for cable
specifications. Failure to use proper cable can result in damage to equipment
or danger to personnel.
©2021 Signify Holding. all rights reserved. all trademarks are owned by
Signify Holding or their respective owners. the information provided herein is
subject to change, without notice. Signify does not give any representation or
warranty as to the accuracy or completeness of the information included herein
and shall not be liable for any action in reliance thereon. the information
presented in this document is not intended as any commercial offer and does
not form part of any quotation or contract unless otherwise agreed by Signify.
data subject to change.
CUSTOMER SERVICE
if you have any questions regarding this product, please contact Customer
Service by phone at +1 214-647-7880 or
by email at entertainment. service@signify.com.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>