Important Information
This document provides basic setup instructions and safety warnings for the following product(s):
64505-002 | Leko LED Profile Tunable Warm White |
---|
Read all instructions before installing or using this product. Retain this manual for future reference. Additional product information and descriptions may be found on the product specification sheet.
INCLUDED ITEMS
-
Leko LED Profile
-
QUICK START GUIDE (this document)
-
POWER CONNECTOR
-
WARRANTY CARD
INSTALLATION AND SETUP
MOUNTING
The unit should be mounted via its screw holes on the bracket. Always ensure
that the unit is firmly fixed to avoid vibration and slipping while operating.
Always ensure that the structure to which you are attaching the unit is secure
and is able to support a weight of 10 times of the unit’s weight. Always use a
safety cable that can hold up to 12 times the weight of the unit when
installing the fixture.
The luminaire must be mounted by professionals.
NOTE: lens tube sold separately
SET UP
Control Panel
-
LCD display – shows the menu and selected functions
-
MENU – To select the programming functions
DOWN – To go backward in the selected functions
UP – To go forward in the selected functions
ENTER – To confirm the selected functions -
DMX IN – 5-pin XLR cable to link DMX console
-
DMX OUT – 5-pin XLR cable to link to the next unit
-
Power In – connects to power supply
-
Power Out – connects to next fixture
QUICK REFERENCE DMX MAPS
16-BIT CHANNEL MODE
DMX CHANNEL | PARAMETER |
---|---|
1 | Intensity (High) |
2 | Intensity (Low) |
3 | Strobe |
4 | Fan Control |
5 | Control Channel |
6 | TW LED (High) |
7 | TW LED (Low) |
8-BIT CHANNEL MODE
DMX CHANNEL | PARAMETER |
---|---|
1 | Intensity (High) |
2 | Strobe |
3 | Fan Control |
4 | Control Channel |
5 | TW LED |
2 CHANNEL MODE
DMX CHANNEL | PARAMETER |
---|---|
1 | Intensity |
2 | TW LED |
COMPLIANCE
This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when this equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with Vari-Lite system, service, and safety guidelines, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his/ her own expense.
DECLARATION OF CONFORMITY
We declare, under our sole responsibility, that this product complies with the relevant clauses of the following standards and harmonized documents:
SAFETY
- EN 60598-1:2015 + A1:2018;
- EN 60598-2-17:2018;
- EN 60598-2-4:2018;
- EN 62493:2015;
- EN 62471:2008;
- EN 62031: 2008 + A1: 2013 + A2: 2015;
- EN 61347-2-11:2001;
- EN 61347-1:2015 Low Voltage Directive 2014/35/EU
EMC
- EN 55032:2015
- EN 55103-2: 2009
- EN 61000-3-2:2014
- EN 61000-3-3:2013
- EN 55015:2013+A1:2015
- EN 61547:2009
- EMC Directive 2014/30/EU
ROHS
EN 62321:2012
We certify that the product conforms to the protection requirements of council
directives: Low Voltage Directive 2014/35/EU, 2014/30/EU (EMC), and
Restriction of the use of certain Hazardous Substances in electrical and
electronic equipment Directive (RoHS), 2015/863. Equipment referred to in this
declaration of conformity was first manufactured in 2017 in compliance with
these standards.
LIMITED 2-YEAR WARRANTY
Vari-Lite offers a two-year limited warranty on its control products against defects in materials or workmanship from the date of delivery. A copy of Vari- Lite two-year limited warranty containing specific terms and conditions can be obtained from the Vari-Lite website at www.vari-lite.com or by contacting your local Vari-Lite office.
SAFETY WARNINGS AND NOTICES
When using electrical equipment, basic safety precautions should always be followed including the following:
READ AND FOLLOW ALL SAFETY INSTRUCTIONS.
- For indoor, dry locations use only. Do not use outdoors.
- Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel.
- The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition.
- Not for residential use. Do not use this equipment for other than intended use.
- Refer service to qualified personnel.
- The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition.
- Not for residential use. Do not use this equipment for other than intended use.
- Refer service to qualified personnel. This fixture contains no user serviceable parts.
- Prior to first use, carefully inspect unit for damage from shipping.
- Installation and operation to be performed by qualified personnel only.
- Use safety tether when mounting.
- Install only in locations with adequate ventilation of at least 50cm clearance from adjacent surfaces.
- Ensure sure that ventilation slots are not blocked.
- Ensure that the voltage and frequency of the power supply match the power requirements of the fixture.
- The fixture must be earthed/grounded to the appropriate conductor.
- Do not operate fixture outside the ambient temperature range of 0–40°C.
- Do not connect the fixture to any dimmer pack.
- New fixtures may emit a chemical odor due to the manufacturing process. This odor will dissipate over time.
- Note distance requirement(s) from combustible materials or illuminated objects. Do not mount near gas or electric heaters.
- Prior to each use, carefully inspect power cables and replace any damaged cables.
- Exterior surfaces of the luminaire will be hot during operation. Take appropriate precautions.
- Continuous use of the fixture may shorten the lifespan. Power down the fixture when not in use.
- Clean fixtures regularly, particularly when working in a dusty environment.
- Never touch power cables or wires while the fixture is powered on.
- Avoid entangling power wires with other cables.
- In the event of a serious operating problem, immediately discontinue using the fixture.
- Never turn on and off the unit time after time.
- The housing, lenses, and/or the ultraviolet filter must be replaced if they are damaged.
- Disconnect mains power if the fixture is not used for a long time.
- Original packing materials can be reused for transporting the fixture.
- This fixture is designed for dry locations only. Exposure to rain or moisture may damage fixture unless it is suitably IP rated.
- Do not look directly at the LED light beam while the fixture is on.
- Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel.
SAVE THESE INSTRUCTIONS.
WARNING: Refer to National Electrical Code® and local codes for cable specifications. Failure to use proper cable can result in damage to equipment or danger to.
CUSTOMER SERVICE
If you have any questions regarding this product, please contact Customer Service at +1-214-647-7880 or via e-mail at entertainment.service@signify.com.
© 2020 Signify Holding. All rights reserved.
All trademarks are owned by Signify Holding or their respective owners. The
information provided herein is subject to change, without notice. Signify does
not give any representation or warranty as to the accuracy or completeness of
the information included herein and shall not be liable for any action in
reliance thereon. The information presented in this document is not intended
as any commercial offer and does not form part of any quotation or contract,
unless otherwise agreed by Signify. Data subject to change.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>