pontec 2500 PondoMax Eco Pond Pump Instruction Manual
- June 4, 2024
- pontec
Table of Contents
- pontec 2500 PondoMax Eco Pond Pump
- Parts description
- Correct electrical installation
- Safe operation
- Intended use
- Installation and connection Connecting the hose
- Commissioning/start up
- Malfunction remedy
- Maintenance and cleaning
- PondoMax Eco 1500/2500 Cleaning/replacing the impeller unit
- PondoMax Eco 5000/8000/11000/14000/17000
- Storage/winter protection
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
pontec 2500 PondoMax Eco Pond Pump
Parts description
PondoMax Eco 1500/2500
PondoMax Eco 3500
PondoMax Eco 5000/8000/11000/14000/17000
WARNING
- This unit can be used by children aged 8 and above and by persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they are supervised or have been in-structed on how to use the unit in a safe way and they understand the hazards involved.
- Do not allow children to play with the unit. Only allow children to carry out cleaning and user maintenance under supervision.
- Ensure that the unit is fused for a rated fault current of max. 30 mA by means of a fault current protection device.
- Only connect the unit if the electrical data of the unit and the power supply correspond.
- The unit data is to be found on the unit type plate, on the packaging or in this manual.
- Possible death or severe injury from electrocution.
- Before reaching into the water, disconnect all electrical units in the water from the mains.
- Only operate the unit if no persons are in the water.
- Do not use the unit if electrical cables or housings are damaged.
- A damaged connection cable cannot be replaced.
- Dispose of the unit.
Safety information
Correct electrical installation
- Electrical installations must meet the national regulations and may only be carried out by a qualified electrician.
- A person is regarded as a qualified electrician if, due to his/her vocational education, knowledge and experience, he or she is capable of and authorised to judge and carry out the work commissioned to him/her.
- This also includes the recognition of possible hazards and the adherence to the pertinent regional and national standards, rules and regulations.
- For your own safety, please consult a qualified electrician.
- Extension cables and power distributors e.g. outlet strips must be suitable for outdoor use splash proof.
- Protect the plug connection from moisture.
- Only connect the unit to a correctly fitted socket.
Safe operation
- The impeller unit in the pump contains a magnet with a strong magnetic field that may affect the operation of pace-makers or implantable cardioverter defibrillators (ICDs).
- Always keep magnets at least 0.2 m away from implanted devices.
- Keep the socket and power plug dry.
- Never carry or pull the unit by the electrical cable.
- Route cables such that they are protected from damage and do not present a tripping hazard.
- Never carry out technical changes to the unit.
- Only carry out work on the unit.
- If problems cannot be overcome, please contact an authorised customer service point or, if in doubt, the manufacturer.
- Only use original spare parts and accessories for the unit.
Information about these operating instructions
You made a good choice with the purchase of this product PondoMax Eco 1500/2500/3500/5000/8000/11000/14000/17000. Prior to commissioning the unit, please read the instructions of use carefully and fully familiarise yourself with the unit. Ensure that all work on and with this unit is only carried out in accordance with these instructions. Adhere to the safety information for the correct and safe use of the unit. Keep these instructions in a safe place! Please also hand over the instructions when passing the unit on to a new owner. Warnings used in these instructions The warning information is categorised by signal words, which indicate the extent of the hazard.
WARNING
- Indicates a possibly hazardous situation.
- Non-observance may lead to death or serious injuries.
CAUTION
- Indicates a possibly hazardous situation.
-
- Non-observance may lead to slight or minor injuries.
NOTE
Information for the purpose of clarification or for preventing possible damage
to assets or to the environment
Intended use
Only use the product described in this manual as follows
- For pumping normal pond water for water features and fountains.
- Operate in accordance with instructions.
The following restrictions apply to the unit:
- Do not use in swimming ponds.
- Never use the unit with fluids other than water.
- Never run the unit without water.
- Do not use for commercial or industrial purposes.
- Do not use in conjunction with chemicals, foodstuff, easily flammable or explosive substances.
- Do not connect to the domestic water supply.
Installation and connection Connecting the hose
How to proceed
- Shorten the stepped hose adapter to the diameter of the hose used if necessary.
- This reduces pressure losses.
- Screw the stepped hose adapter to the outlet.
- Slip the hose clip over the hose, fit the hose onto the hose connector and secure with the hose clip.
Installing the unit
- Never operate the pump in a swimming pond.
- Ensure that the connection to the power supply is at least 2 m from the pond.
- Place the unit horizontally on the ground ensuring its stable position.
Commissioning/start up
NOTE
The unit will be destroyed if it is operated with a dimmer. It contains
sensitive electrical components. Do not connect the unit to a dimmable power
supply.
Switching on
Connect the unit to the mains. The unit switches on immediately.
Switching off
Disconnect the unit from the mains.
Malfunction remedy
Maintenance and cleaning
Cleaning the device
Recommendation regarding cleaning
- Clean the unit as required but at least twice a year.
- When cleaning the pump, pay particular attention to the cleaning of the impeller unit and pump housing.
- In the event of the filter housing capacity reducing, clean the unit under running water using a brush.
- Do not not use cleaning agents or chemical solutions.
- Recommended cleaning agent for removing stubborn limescale deposits:
- Vinegar and chlorine-free household cleaning agent.
- After cleaning, thoroughly rinse all parts in clean water.
PondoMax Eco 1500/2500 Cleaning/replacing the impeller unit
How to proceed
- Remove screws.
- The screws are used as transport protection and not required for operation.
- Actuate the engagement hook and fold up the strainer top casing.
- Remove pump.
- Unscrew the pump housing and pull out the impeller unit.
- Clean all components under running water using a soft brush, replace damage parts.
- Reassemble the unit in the reverse order.
- Place the pump cable into the cable opening of the bottom strainer casing such that the cable will not be crushed when closing the filter housing.
Remove screws
- The screws are used as transport protection and not required for operation.
- Actuate the engagement hook and fold up the strainer top casing.
- Remove pump.
- Unscrew the pump housing by turning counter-clockwise and remove bayonet closing mechanism.
- Clean all components under running water using a soft brush, replace damage parts.
- Reassemble the unit in the reverse order.
- Place the pump cable into the cable opening of the bottom strainer casing such that the cable will not be crushed when closing the filter housing.
PondoMax Eco 3500 Cleaning/replacing the impeller unit
- Remove screws.
- The screws are used as transport protection and not required for operation.
- Actuate the engagement hook and fold up the strainer top casing.
- Remove pump.
- Unscrew the pump housing by turning counter-clockwise and remove (bayonet closing mechanism).
- Clean all components under running water using a soft brush, replace damage parts.
- Reassemble the unit in the reverse order.
- Place the pump cable into the cable opening of the bottom strainer casing such that the cable will not be crushed when closing the filter housing.
PondoMax Eco 5000/8000/11000/14000/17000
Cleaning/replacing the impeller unit
How to proceed
- Remove screws.
- The screws are used as transport protection and not required for operation.
- Actuate the engagement hook and fold up the strainer top casing.
- Remove pump.
- Remove screws.
- Remove the pump housing including its holding ring, sealing and impeller unit.
- Clean all components under running water using a soft brush, replace damage parts.
- Reassemble the unit in the reverse order.
- Place the pump cable into the cable opening of the bottom strainer casing such that the cable will not be crushed when closing the filter housing.
Storage/winter protection
The unit is not frost-proof and has to be removed and put into storage if minus temperatures are expected.
How to correctly store the unit
Thoroughly clean the unit, check it for damage and replace any damaged parts.
- Protect electrical connections from moisture and dirt.
- Store the pump submerged and in a frost-free environment.
- Protect open plug connections from moisture and dirt.
Wear parts
Impeller unit
Disposal
NOTE
Do not dispose of this unit with domestic waste. Render the unit unusable
beforehand by cutting the cables and dispose of the unit via the return system
provided for this purpose.
Guarantee conditions
PfG grants a 3 year guarantee from the date of sale on proven material and
manufacturing faults. Wear parts such as bulbs etc. are exempted from the
guarantee. Prerequisite for our guarantee is the presentation of the purchase
receipt. Our guarantee will become null and void if the unit is misused,
electrically or mechanically damaged by inappropriate use and improper repair
by non-authorised workshops. Repairs are reserved for workshops authorised by
PfG or by PfG itself. In the case of warranty claims, please return the
defective unit or part freight paid to PfG together with a description of the
fault and the purchase receipt. PfG reserves the right to invoice repair
costs. PfG is not liable for transport damage. Any damage must be claimed
against the carrier. Further claims of whatever type, especially consequential
damage, are excluded. This guarantee does not affect the final customer’s
claims against the dealer.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>