pontec 43189 Pond Fogger PondoFog Instruction Manual

June 4, 2024
pontec

pontec 43189 Pond Fogger PondoFog

Operating Instructions

Original operating manual. This operating manual belongs with the unit and must always be handed over together with the unit.

WARNING

  • Disconnect all electrical units in the water from the power supply before reaching into the water. Otherwise there is a risk of injuries or death by electrocution.
  • Only operate the unit if no persons are in the water.
  • Disconnect the power plug before carrying out any work on the unit.
  • This unit can be used by children aged 8 and above and by per-sons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they are supervised or have been instructed on how to use the unit in a safe way and they under-stand the hazards involved. Do not allow children to play with the unit. Only allow children to carry out cleaning and user mainte-nance under supervision.

Safety information

Correct electrical installation

  • Special regulations apply to electrical installation in outdoor areas. Only allow a qualified electrician to perform the electrical installation.
    • The qualified electrician has the required professional training, knowledge and skills to perform electrical installa-tions in outdoor areas. The qualified electrician can detect potential risks and adheres to regional and national standards, regulations and directives.
    • For your own safety, please consult a qualified electrician.
  • Only connect the unit if the electrical data of the unit and the power supply match.
  • Only plug the unit into a correctly installed outlet. Ensure that the unit is fused for a rated fault current of max. 30 mA by means of a fault current protection device.
  • Install the transformer at a minimum safety distance of 2 m from the water.
  • Extension cables and power distributors (e.g. outlet strips) must be suitable for outdoor use (splash-proof).
  • Protect open plugs and sockets from moisture.

Safe operation

  • The power pack or transformer and plug connections are only protected from rain and splash water, they are not waterproof. Ensure that they are never placed in water.
  • Do not use the unit, if electrical lines or the housing are damaged.
  • A damaged connection cable cannot be replaced. Dispose of the unit.
  • Do not carry or pull the unit by its power cable.
  • Route lines so that they are protected from damage and nobody can trip over them.
  • Never make technical modifications to the unit.
  • Only carry out work on the unit that is described in this manual.
  • Only use original spare parts and accessories.

Product Description

pontec 43189 Pond Fogger PondoFog fig
1

A Quantity Description
1 1 Float unit
2 1 Fogger unit with 8 m connection cable
3 1 Membrane key
4 1 Transformer with 2 m connection cable

Intended use

Only use the product described in this manual as follows:

  • For creating light and mist effects.
  • For use in water fountain systems and ponds.
  • For use above and underwater.
  • Operate the product in compliance with the technical data. (→ Technical data)

The following restrictions apply to the unit:

  • Operation in swimming pools, bathtubs or bodies of water which could be used by persons is prohibited!
  • Do not use it for commercial or industrial purposes.
  • Do not use it for long-term operation.
  • Never run the unit without water.
  • Do not use in conjunction with chemicals, foodstuff, easily flammable or explosive substances.

Installation and connection

Fig B, C
Position and secure the units so that they cannot present a hazard:pontec
43189 Pond Fogger PondoFog fig 2 pontec
43189 Pond Fogger PondoFog fig 3

  • Install the transformer at a minimum safety distance of 6.5 ft from the water.

How to proceed:

  1. Route the connection cable of the misting unit through the float unit.
  2. Place the misting unit in the float unit. Ensure that the LEDs point upwards.
  3. Connect the plug of the connection cable to the outlet on the transformer and hand-tighten the union nut.
  4. Place the misting unit in the water.

Commissioning/start-up

NOTE

The unit will be destroyed if it is operated with a dimmer. It contains sensitive electrical components.

  • Do not connect the unit to a dimmable power supply.

Switching on: Plug the power plug of the transformer into the power outlet.

  • Check the function of the misting unit.

Switching off: Disconnect the transformer power plug.

The operating life of the membrane depends on the operating time, water hardness, water purity etc. PfG recommends: Do not use the unit for longer than 4 to 6 hours a day.

Maintenance and cleaning

Cleaning the unit

NOTE

Do not use aggressive cleaning agents or chemical solutions. These agents can damage the housing, impair the func-tion of the device and harm animals, plants and the environment.

  • Clean the unit only with clean water and a soft brush or sponge.

Replacing the membrane

  • Only use original spare parts from PfG.
    • The unit may be damaged by the use of spare parts from other manufacturers.

How to proceedpontec 43189 Pond Fogger PondoFog fig
4

  1. Position the membrane key with the notches on the ring nut and unscrew the ring nut in a counter-clockwise direc-tion.
  2. Remove the membrane and O-ring, check for damage, clean and, if necessary, replace.
  3. Reassemble the unit in the reverse order.
    • Ensure that the O-ring is correctly positioned.
  4. Reconnect to the power supply and check the function.

Storage/overwintering
If the ambient temperature falls outside the permissible ambient temperature range, it is necessary to remove the unit. (→ Technical data)

  • Store the unit in a dry and frost-free place.

Troubleshooting

Malfunction Cause Remedy
LEDs are not lit Power supply interrupted Check power supply
Transformer defective Replace transformer
Bulb defective Bulbs cannot be replaced. Dispose of bulbs.
Illuminating power decreasing Lamp glass soiled Clean
No mist generated Membrane worn Replace membrane

Technical data

PondoFog RGB

Transformer| Connection voltage| V AC| 230-240
Power frequency| Hz| 50
Max. power consumption| W| 13
Output voltage| V AC| 24
Max. power output| VA| 24
Protection type|  | IP44
Length of power cable| m| 2
Weight| kg| 0.65
Misting unit with LED| Connection voltage| V AC| 24
Power consumption| W| 23
Protection type|  | IP68
Max. immersion depth| m| 1
LED color space| –| RGB
Misting unit water consumption| l/h| 0.5
Permissible water temperature| °C| +4 … +35
Connection cable length| m| 8
Dimensions (Ø × H)| mm| 120 × 75
Weight| kg| 0.35

Symbols on the unitpontec 43189 Pond Fogger PondoFog fig
5

Wear parts

  • Membrane

Disposal

NOTE

Do not dispose of this unit with domestic waste.

  • Dispose of the unit by using the return system provided for this purpose.
  • Disable the unit by cutting off the cables.

Warranty conditions

PfG grants a 2-year warranty from the date of sale on verifiable material and manufacturing defects. Wear parts such as bulbs etc. are exempt from the warranty. The prerequisite for our warranty is the presentation of the purchase receipt. Our warranty will become null and void if the unit is misused, electrically or mechanically damaged by inappropriate use or improperly repaired by non-authorized workshops. Repairs may only be performed by PfG or workshops authorized by PfG. In the case of warranty claims, please return the defective unit or part freight paid to PfG together with a description of the fault and the purchase receipt. PfG reserves the right to invoice repair costs. PfG is not liable for transport damage. Any damage must be claimed against the carrier. Further claims of whatever type, especially consequential damage, are excluded. This warranty does not affect the final customer’s claims against the dealer.

Installation Instruction

pontec 43189 Pond Fogger PondoFog fig
7

Tecklenburger Straße 161
D – 48477 Hörstel
Germany
www.pontec.com

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals