pontec 87589 PondoTronic UVC 11 Device Instruction Manual

June 4, 2024
pontec

pontec 87589 PondoTronic UVC 11 Device

Original operating manual. This operating manual belongs with the unit and must always be handed over together with the unit.

WARNING

  • Disconnect all electrical units in the water from the power supply before reaching into the water. Otherwise there is a risk of injuries or death by electrocution.
  • This unit can be used by children aged 8 and above and by per-sons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they are supervised or have been instructed on how to use the unit in a safe way and they under-stand the hazards involved. Do not allow children to play with the unit. Only allow children to carry out cleaning and user mainte-nance under supervision.

Safety information

Electrical connection

  • Special regulations apply to electrical installation in outdoor areas. Only allow a qualified electrician to perform the electrical installation.
    • The qualified electrician has the required professional training, knowledge and skills to perform electrical installa-tions in outdoor areas. The qualified electrician can detect potential risks and adheres to regional and national standards, regulations and directives.
    • For your own safety, please consult a qualified electrician.
  • Only connect the unit if the electrical data of the unit and the power supply match.
  • Only plug the unit into a correctly installed outlet. Ensure that the unit is fused for a rated fault current of max. 30 mA by means of a fault current protection device.
  • Extension cables and power distributors (e.g. outlet strips) must be suitable for outdoor use (splash-proof).
  • Protect open plugs and sockets from moisture.

Safe operation

  • Do not use the unit, if electrical lines or the housing are damaged.
  • A damaged connection cable cannot be replaced. Dispose of the unit.
  • Do not carry or pull the unit by its power cable.
  • Route lines so that they are protected from damage and nobody can trip over them.
  • Never make technical modifications to the unit.
  • Only carry out work on the unit that is described in this manual.
  • Only use original spare parts and accessories.

Product description

Scope of delivery

5 A|
---|---
1| Casing
2| Unit head with UVC lamp
3| Æ 19 … 38 mm (0.75….. 1.5 inch) stepped hose adapter with O-ring
4| Operating instructions

Function description

The special UVC radiation of the UVC clarifier eliminates floating algae and other algae that give water a green color. It also kills bacteria and other germs. The UVC clarifier is integrated in the water circuit, ideally upstream of a filter.

Intended use

Only use the product described in this manual as follows:

  • For cleaning garden ponds.
  • For operation with clean water.
  • Operate the product in compliance with the technical data. (→ Technical data)

The following restrictions apply to the unit:

  • This product is not suitable for general lighting, but is only intended for the purpose described here.
  • The UVC clarifier installed in the device kills algae and bacteria in the pond water. The UVC lamp may never be used for any other purpose or outside of the casing.
  • Do not use for commercial or industrial purposes.
  • Never use the unit with fluids other than water.
  • Not to be used for sterilizing drinking water or other fluids.
  • Do not use in conjunction with chemicals, foodstuff, easily flammable or explosive substances.

Installation and connection

Prerequisite
The unit head is removed. (→ Dismantling the unit head)

Installing the unit

How to proceed:

  • Install the unit at least 2 m (6.5 ft) from the edge of the pond.
  • Only install the unit in the permitted positions to ensure fault-free operation.
  • Allow sufficient space for carrying out maintenance work.
  • Reinstall the unit head after screwing the casing to the ground. (→ Fitting the unit head)
Establishing the connections

How to proceed:

  1. Shorten the stepped hose adapter to the diameter of the hose used if necessary.
    This reduces pressure losses.

  2. Slip the hose clip over the hose, fit the hose onto the hose connector and secure it with the hose clip.
    In the case of a stepped hose adapter with a separate union nut, first push the union nut over the hose.

  3. Connect the stepped hose adapter with seal to the casing.

    • Connect the inlet and outlet.
    • Hand tighten the stepped hose adapter.
Commissioning/start-up

Prerequisite

  • First switch on the pump, then the UVC clarifier.
  • Check all connections for leaks.

Switching on/switching off

  • Switching on: Plug the power plug into the outlet.
    The unit switches on immediately.

  • Switching off: Pull the power plug from the outlet.

Checking the function  E

The function display is lit when the UVC lamp is switched on.

Maintenance and cleaning

NOTE
Do not use aggressive cleaning agents or chemical solutions. These agents can damage the housing, impair the func-tion of the device and harm animals, plants and the environment.

Only clean the unit from the outside with clear water and a soft brush.

Recommended cleaning agent for removing stubborn limescale deposits:
Vinegar- and chlorine-free household cleaning agent.

Dismantling the unit head

CAUTION
The ultra-violet radiation of the UVC lamp can burn your eyes and skin.

  • Never operate the UVC lamp outside out the casing or in a damaged casing.
  • Disconnect the unit from the power grid before starting any maintenance work or before replacing the UVC lamp.

CAUTION
The quartz glass and UVC lamp could break and cause cuts.

  • Act with caution when performing work on the UVC clarifier in order to avoid cuts.
  • Avoid shocks, impacts and abrupt movements to prevent the glass from breaking.
How to proceed: F
  1. Turn the unit head counter-clockwise up to the stop and carefully pull it out of the casing together with the O-ring.
  2. Clean the casing from the inside and the outside.
    For safety reasons, the UVC lamp can only be turned on when the UVC clarifier is properly installed in the unit.
Fitting the unit head

How to proceed:
G

  1. Check the O-ring on the unit head for correct fit.
    Clean the O-ring, replace if damaged.

  2. Carefully push the unit head into the casing up to the stop while applying slight pressure.
    Turn the unit head slightly so that the pins and grooves of the bayonet closure mesh.

  3. Turn the unit head clockwise up to the stop.
    The two arrows on the casing and unit head must point towards one another.

Cleaning the quartz glass / replacing the UVC lamp
Replace the UVC lamp after max. 8,000 operating hours. This ensures optimum filtering performance.

CAUTION
The quartz glass and UVC lamp could break and cause cuts.

  •  Act with caution when performing work on the UVC clarifier in order to avoid cuts.
  • Avoid shocks, impacts and abrupt movements to prevent the glass from breaking.
Prerequisite
  • The unit head is removed. (→ Dismantling the unit head)
  • Ensure that the identification and power data of the UVC lamps used correspond to the information on the unit type
    plate. (→ Technical data)
How to proceed: H

pontec 87589 PondoTronic UVC 11 Device-fig9

  1. Loosen the self-tapping screw until the the screw tip is sunk into the casing of the clamping screw.
  2. Unscrew the clamping screw in counter-clockwise direction.
  3. Remove the quartz glass including the O-ring towards the front with a slight turning movement.
  4. Pull out and replace the UVC lamp.
  5. Carefully push the quartz glass with the O-ring up to the stop in the unit head.
    • Clean the O-ring, replace if damaged.
    • Ensure that the O-ring is located in the gap between the unit head and the quartz glass.
  6. Tighten the clamping screw clockwise up to the stop.
  7. Tighten the self-tapping screw.
  8. Wipe the quartz glass tube with a damp cloth.
  9. On completion of the work, fit the unit head. (→ Fitting the unit head)
Storage/overwintering

If the ambient temperature falls outside the permissible ambient temperature range, it is necessary to remove the unit. (→ Technical data)

Store the unit in a dry and frost-free place.

Troubleshooting

Malfunction Cause Remedy
The performance of the unit is not satisfactory The water is extremely
soiled Remove algae and leaves from the pond

Replace the water
The quartz glass is soiled| Clean the quartz glass
The UVC lamp power is exhausted| The lamp must be replaced after 8000 operat- ing hours.
Flow rate is too high| Reduce the pump capacity
The UVC lamp is not lit| Power plug not connected| Connect the power plug
The UVC lamp is defective| Replace the UVC lamp
Connection defective| Check the electrical connection

Technical data

Description PondoTronic UVC 7 PondoTronic UVC 11
Rated mains voltage V AC 230 230
Power frequency Hz 50 50
Power consumption W 11 14
Length of power cable ft 9.8 9.8
Protection type IP24 IP24
Permissible water temperature range °F +39 … +95 +39 … +95
UVC lamp Type 7 W TC-S (UV-C)
Flow rate maximum gal/h 449
Operating pressure maximum bar 0.5
Dimensions Length inch 13
Width inch 4.72 4.72
Height inch 3.93 3.93
Weight lbs 3.08 3.08

 Symbols on the unit

pontec 87589 PondoTronic UVC 11 Device-fig10

Wear parts

UVC lamp, quartz glass and O-ring for quartz glass

Disposal

NOTE Do not dispose of this unit with domestic waste.

  • Dispose of the unit by using the return system provided for this purpose.
  • Disable the unit by cutting off the cables.
  • Dispose of UVC lamps by availing of the take-back system in place for this purpose.

Warranty conditions

PfG grants a 2 year warranty from the date of sale on verifiable material and manufacturing defects. Wear parts such as bulbs etc. are exempt from the warranty. The prerequisite for our warranty is the presentation of the purchase re-ceipt. Our warranty will become null and void if the unit is misused, electrically or mechanically damaged by inappropri-ate use or improperly repaired by non-authorised workshops. Repairs may only be performed by PfG or workshops authorised by PfG. In the case of warranty claims, please return the defective unit or part freight paid to PfG together with a description of the fault and the purchase receipt. PfG reserves the right to invoice repair costs. PfG is not liable for transport damage. Any damage must be claimed against the carrier. Further claims of whatever type, especially consequential damage, are excluded. This warranty does not affect the final customer’s claims against the dealer.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

pontec User Manuals

Related Manuals