pontec PondoMax Eco 17000 Pond Pump Instruction Manual

June 5, 2024
pontec

pontec PondoMax Eco 17000 Pond Pump

Safety information

Correct electrical installation

  • Electrical installations must meet the national regulations and may only be carried out by a qualified electrician.
  • A person is regarded as a qualified electrician if, due to his/her vocational education, knowledge and experience, he or she is capable of and authorised to judge and carry out the work commissioned to him/her. This also includes the recognition of possible hazards and the adherence to the pertinent regional and national standards, rules and regulations.
  • For your own safety, please consult a qualified electrician.
  • Extension cables and power distributors (e.g. outlet strips) must be suitable for outdoor use (splash-proof).
  • Protect the plug connection from moisture.
  • Only connect the unit to a correctly fitted socket.

Safe operation

  • The impeller unit in the pump contains a magnet with a strong magnetic field that may affect the operation of pace- makers or implantable cardioverter defibrillators (ICDs). Always keep magnets at least 0.2 m away from implanted
    devices.

  • Keep the socket and power plug dry.

  • Never carry or pull the unit by the electrical cable.

  • Route cables such that they are protected from damage and do not present a tripping hazard.

  • Never carry out technical changes to the unit.

  • Only carry out work on the unit that is described in this manual. If problems cannot be overcome, please contact an authorised customer service point or, if in doubt, the manufacturer.

  • Only use original spare parts and accessories for the unit.

Information about these operating instructions

You made a good choice with the purchase of this product PondoMax Ec 1500/2500/3500/5000/8000/11000/14000/17000.

Prior to commissioning the unit, please read the instructions of use carefully and fully familiarise yourself with the unit.
Ensure that all work on and with this unit is only carried out in accordance with these instructions. Adhere to the safety information for the correct and safe use of the unit. Keep these instructions in a safe place! Please also hand over the instructions when passing the unit on to a new owner.

Warnings used in these instructions

The warning information is categorised by signal words, which indicate the extent of the hazard.

WA R N I N G

  • Indicates a possibly hazardous situation.
  • Non-observance may lead to death or serious injuries.

C A U T I O N

  • Indicates a possibly hazardous situation.
  • Non-observance may lead to slight or minor injuries.

N O T E
Information for the purpose of clarification or for preventing possible damage to assets or to the environment.

Cross-references used in these instructions

  • A reference to a figure, e.g. figure A.
  • Reference to another section.

Intended use
Only use the product described in this manual as follows:

  • For pumping normal pond water for water features and fountains.

  • Operate in accordance with instructions.
    The following restrictions apply to the unit:

  • Do not use in swimming ponds.

  • Never use the unit with fluids other than water.

  • Never run the unit without water.

  • Do not use for commercial or industrial purposes.

  • Do not use in conjunction with chemicals, foodstuff, easily flammable or explosive substances.

  • Do not connect to the domestic water supply.

Installation and connection

Connecting the hose
How to proceed:

A

  1. Shorten the stepped hose adapter to the diameter of the hose used if necessary.
    This reduces pressure losses.

  2. Screw the stepped hose adapter to the outlet.

  3. Slip the hose clip over the hose, fit the hose onto the hose connector and secure with the hose clip.

Installing the unit

B

  • Never operate the pump in a swimming pond.
  • Ensure that the connection to the power supply is at least 2 m from the pond.
    Place the unit horizontally on the ground ensuring its stable position.

Commissioning/start-up

N O T E
The unit will be destroyed if it is operated with a dimmer. It contains sensitive electrical components.

  • Do not connect the unit to a dimmable power supply.

Switching on: Connect the unit to the mains. The unit switches on immediately.
Switching off: Disconnect the unit from the mains.

Malfunction remedy

M alfunction Cause R emedy
Pump does not start No mains voltage Check mains voltage

Clean/check supply lines

Pump does not deliver| Filter housing clogged| Clean strainer casings

Reduce hose length to the necessary mini- mum, do not use unnecessary connection parts

Insufficient delivered quantity| Filter housing clogged

Excessive loss in the supply hoses

| Clean strainer casings

Reduce hose length to the necessary mini- mum, do not use unnecessary connection parts

Pump switches off after a short running time| Excessively soiled water

Water temperature too high

| Clean pump

Note maximum water temperature of +35 °C

Maintenance and cleaning

Cleaning the device
Recommendation regarding cleaning:

  • Clean the unit as required but at least twice a year.
  • When cleaning the pump, pay particular attention to the cleaning of the impeller unit and pump housing.
  • In the event of the filter housing capacity reducing, clean the unit under running water using a brush.
  • Do not not use cleaning agents or chemical solutions.
  • Recommended cleaning agent for removing stubborn limescale deposits:
    • Vinegar- and chlorine-free household cleaning agent.
  • After cleaning, thoroughly rinse all parts in clean water.

PondoMax Eco 1500/2500

Cleaning/replacing the impeller unit

How to proceed:
C

  1. Remove screws.
    The screws are used as transport protection and not required for operation.

  2. Actuate the engagement hook and fold up the strainer top casing.

  3. Remove pump.

  4. Unscrew the pump housing and pull out the impeller unit.
    Clean all components under running water using a soft brush, replace damage parts.

  5. Reassemble the unit in the reverse order.
    Place the pump cable into the cable opening of the bottom strainer casing such that the cable will not be crushed when closing the filter housing.

PondoMax Eco 3500

Cleaning/replacing the impeller unit

How to proceed:

D

  1. Remove screws.
    The screws are used as transport protection and not required for operation.

  2. Actuate the engagement hook and fold up the strainer top casing.

  3. Remove pump.

  4. Unscrew the pump housing by turning counter-clockwise and remove (bayonet closing mechanism).
    Clean all components under running water using a soft brush, replace damage parts.

  5. Reassemble the unit in the reverse order.
    Place the pump cable into the cable opening of the bottom strainer casing such that the cable will not be crushed when closing the filter housing.

PondoMax Eco 5000/8000/11000/14000/17000

Cleaning/replacing the impeller unit

How to proceed:

E

  1. Remove screws.
    The screws are used as transport protection and not required for operation.

  2. Actuate the engagement hook and fold up the strainer top casing.

  3. Remove pump.

  4. Remove screws.

  5. Remove the pump housing including its holding ring, sealing and impeller unit.
    Clean all components under running water using a soft brush, replace damage parts.

  6. Reassemble the unit in the reverse order.
    Place the pump cable into the cable opening of the bottom strainer casing such that the cable will not be crushed when closing the filter housing.

Storage/winter protection

The unit is not frost-proof and has to be removed and put into storage if minus temperatures are expected.

How to correctly store the unit:

  • Thoroughly clean the unit, check it for damage and replace any damaged parts.
  • Protect electrical connections from moisture and dirt.
  • Store the pump submerged and in a frost-free environment.
  • Protect open plug connections from moisture and dirt.

Wear parts

  • Impeller unit

Disposal

N O T E

Do not dispose of this unit with domestic waste.

  • Render the unit unusable beforehand by cutting the cables and dispose of the unit via the return system provided for this purpose.

Guarantee conditions

PfG grants a 3 year guarantee from the date of sale on proven material and manufacturing faults. Wear parts such as bulbs etc. are exempted from the guarantee. Prerequisite for our guarantee is the presentation of the purchase receipt. Our guarantee will become null and void if the unit is misused, electrically or mechanically damaged by inappropriate use and improper repair by non-authorised workshops. Repairs are reserved for workshops authorised by PfG or by PfG itself. In the case of warranty claims, please return the defective unit or part freight paid to PfG together with a description of the fault and the purchase receipt. PfG reserves the right to invoice repair costs. PfG is not liable for transport damage. Any damage must be claimed against the carrier.Further  claims of whatever  type, especially consequential damage, are excluded. This guarantee  does not affect the final customer’s claims against the dealer.

| Type| Mains voltage| Power consumption| Max. flow rate| Max. head height| Immersion depth| Water temperature
---|---|---|---|---|---|---|---
PondoMax

Eco

| 1500|

AC 220 … 240 V, 50 Hz

| 25 W| ≤1500 l/h| ≤1.9 m| ≤2 m| +4 … +35 ºC
2500| 40 W| ≤2500 l/h| ≤2.2 m| ≤4 m
3500| 40 W| ≤3500 l/h| ≤2.4 m| ≤4 m
5000| 60 W| ≤5000 l/h| ≤2.6 m| ≤4 m
8000| 70 W| ≤8000 l/h| ≤2.8 m| ≤4 m
11000| 95 W| ≤10000 l/h| ≤3.0 m| ≤4 m
14000| 140 W| ≤13400 l/h| ≤3.2 m| ≤ 4 m
17000| 180 W| ≤17000 l/h| ≤3.5 m| ≤ 4 m

| Type| Weight| Connection to the pump inlet| Connection to the pump outlet| Cable length
---|---|---|---|---|---
PondoMax

Eco

| 1500| 1.9 kg| 25 mm| G1| 10 m
2500| 2.2 kg| 25 mm| G1½| 10 m
3500| 3.1 kg| G1| G1½| 10 m
5000| 3.4 kg| G1½| G1½| 10 m
8000| 4.4 kg| G1½| G1½| 10 m
11000| 4.4 kg| G1½| G1½| 10 m
14000| 5.4 kg| G1½| G1½| 10 m
17000| 5.4 kg| G1½| G1½| 10 m

| | | | | | |
---|---|---|---|---|---|---|---
| Dust tight. Submersible to 2 m depth.| Dust tight. Submersible to 4 m depth.| Remove  the unit at temperatures below zero (centigrade).| Possible hazard for persons wearing  pace makers!| Protect from direct sun radiation.| Do not dispose  of together  with household waste!| Read the operating instructions

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals