TRANE RT-PRC094C Foundation Tons Packaged Rooftop Units Cooling and Gas/Electric User Guide
- June 3, 2024
- Trane
Table of Contents
- TRANE RT-PRC094C Foundation Tons Packaged Rooftop Units Cooling and
- Copyright
- Trademarks
- Revision History
- List of Options
- Table 1. General data—heating performance – 7.5 to 12.5 tons
- Table 2. Unit wiring with cooling only (no electric heat) or gas heat
- Table 3. Electrical characteristics – evaporator fan motor
- Table 4. Unit dimensional data (in inches)
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
TRANE RT-PRC094C Foundation Tons Packaged Rooftop Units Cooling and
Gas/Electric
Copyright
This document and the information in it are the property of Trane, and may not be used or reproduced in whole or in part without written permission. Trane reserves the right to revise this publication at any time, and to make changes to its content without obligation to notify any person of such revision or change.
Trademarks
All trademarks referenced in this document are the trademarks of their respective owners.
Revision History
Updated Model number EBC to ECC.
List of Options
Factory Installed Options | Field Installed Options |
---|---|
10-year Limited Stainless Steel Heat Exchanger Warranty | Barometric Relief |
Damper
High Static Motor Kit(a)| CO2 sensor – Demand Control Ventilation (DCV)
| Condensate Overflow Switch
Economizer (Downflow)
Electric Heaters
Hail/Vandal Guards
High Static Motor Kit(a)
Low Leak Economizer
Manual Outside Air Damper
Motorized 2-Position Damper
Powered Exhaust
Remote Potentiometer
(a) Available on constant volume units only. See product catalog for more information.
Table 1. General data—heating performance – 7.5 to 12.5 tons
Heating Performance (a) | |
---|---|
7.5 to 8.5 Tons | 10 to 12.5 Tons |
Heating Models | Low |
High
Heating Input (Btu/h)| 125,000| 180,000| 225,000| 180,000| 225,000|
250,000
1st Stage (Btu)| 87,500| 126,000| 158,000| 126,000| 158,000| 200,000
Heating Output (Btu/h)| 100,000| 144,000| 180,000| 144,000| 180,000|
200,000
1st Stage (Btu)| 70,000| 100,000| 125,000| 100,000| 125,000| 160,000
Steady State Efficiency %| 81%| 81%| 81%| 81%| 81%| 81%
No. Burners| 3| 5| 6| 5| 6| 6
No. Stages| 2| 2| 2| 2| 2| 2
Gas Supply Line Pressure (in. wc)
Natural Gas (minimum/maximum)| 4.5 / 14.0
in. wc.
| 4.5 / 14.0
in. wc.
| 4.5 / 14.0
in. wc.
| 4.5 / 14.0
in. wc.
| 4.5 / 14.0
in. wc.
| 4.5 / 14.0
in. wc.
Gas Connection Pipe Size (in.)| 1/2 in.| 1/2 in.| 3/4 in.| 1/2 in.| 3/4 in.| 3/4 in.
(a) Heating Performance limit settings and rating data were established and approved under laboratory test conditions using American National Standards Institute standards (ANSI). Ratings shown are for elevations up to 2,000 feet. For elevations above 2,000 feet, ratings should be reduced at the rate of 4% for each 1,000 feet above sea level.
Table 2. Unit wiring with cooling only (no electric heat) or gas heat
Standard Indoor Fan | Oversized Indoor Fan |
---|
Tons
|
Unit Model Number
| Unit Operating Voltage Range| Motor| Motor
Minimum Circuit Ampacity (a)
| Maximum Fuse Size or Maximum Circuit|
Minimum Circuit Ampacity
| Maximum Fuse Size or Maximum Circuit
| | | | Breaker| | Breaker
7.5| E/GCC090A| 208-230| 36| 45| 40| 50
8.5| E/GCC102A| 208-230| 42| 50| 49| 60
10| E/GCC120A| 208-230| 54| 70| 57| 70
12.5| E/GCC150A| 208-230| 66| 80| 69| 80
(a) For Standard and Oversized Indoor Fan Motor, values do not include power exhaust accessory.
Table 3. Electrical characteristics – evaporator fan motor
Tons
|
Unit Model Number
| Standard Evaporator Fan Motor| Oversized Evaporator Fan Motor
---|---|---|---
No.
|
Volts
|
Phase
|
Hp
| Amps|
No.
|
Volts
|
Phase
|
Hp
| Amps
FLA| FLA
7.5| E/GCC090A| 1| 203-230| 3| 2| 7.2| 1| 203-230| 3| 3| 12
8.5| E/GCC102A| 1| 203-230| 3| 2| 7.2| 1| 203-230| 3| 5| 14.6
10| E/GCC120A| 1| 203-230| 3| 3| 12| 1| 203-230| 3| 5| 14.6
12.5| E/GCC150A| 1| 203-230| 3| 3| 12| 1| 203-230| 3| 5| 14.6
Table 4. Unit dimensional data (in inches)
7.5, 8.5, 10, and 12.5 Tons | |
---|---|
Unit Length | 88.25 |
Unit Width | 58.75 |
Unit Height | 49.063 |
Clearance C1 | 60.00 |
Clearance C2 | 48.00 |
Clearance C3 | 48.00 |
Curb Length | 84.80 |
Curb Width | 54.56 |
Supply Length | 32.256 |
Supply Width | 15.52 |
Return Length | 37.921 |
Return Width | 15.799 |
Table 5. Curb matrix
Type
|
Trane
|
Lennox
|
Carrier
|
Bryant
|
JCI/York
|
ICP
Heil
Day and Nigh
|
Goodman Daikin
|
Older Voyager
---|---|---|---|---|---|---|---|---
Gas/Electric| GCC036-060| ZGB 036-060| 48DJ 004-00, 48GJ 006| 579A 036-060|
ZXG 04-06| | CPG (BA) 036-060|
| | | 48HC 004-006, 48HE 004-006| 580C 036-060| ZYG 04-06| DSG 036-060
| | | 48HJ 004-006, 48KC 004-006| 580D 036-060| |
| | | 48LJ 004-006, 48LC 004-006| 580F 036-060| |
| | | 48TC 004-006, 48TF 004-006| 580J 04-06| |
| | | 48TJ 004-006, 48TM 004-006| 581C 036-060| |
| | | 48FC_A04-06, 48FC_B04-06| 581J 04-06| |
| | | 48FC_M07, 48FC_N07| | |
| | | 48GC_M04-05, 48GC_N04-06| | |
| | | 48HC_G04-06, 48LC_A04-06| | |
| | | 48TC_D04-D07, 48KC_A04-06| | |
Electric/| ECC036-060| ZCB 036-060| 50GJ 006, 50HC 004-006| 551B 036-060| ZXE
04-06| | CPC (BA) 036-060|
Electric| | | 50HE 004-006, 50HJ 004-006| 558C 036-060| ZYE 04-06| DSC
036-060
| | | 50KC 004-006, 50LC 004-006| 558D 036-060| |
| | | 50LJ 004-006, 50TC 004-006| 558F 036-060| |
| | | 50TFF 004-006, 50TJ 004-006| 558J 04-06| |
| | | 50TM 004-006, 50TC_B04-07| | |
| | | 50FC_A04-06, 50FC_B04-06| | |
| | | 50FC_M07, 50FC_N07| | |
| | | 50GC_M04-05, 50GC_N04-06| | |
| | | 50HC_G04-06, 50LC_A04-06| | |
| | | 50TC_D04-D07, 50KC_A04-06| | |
Type
|
Trane
|
Lennox
|
Carrier
|
Bryant
|
JCI/York
|
ICP
Heil
Day and Nigh
|
Goodman Daikin
|
Older Voyager
---|---|---|---|---|---|---|---|---
Gas/Electric| GCC090-150| ZGA092-150| 48DJ008 – 01448GJ008 – 012| 581B090 –
150| | PGE090 – 150| CPG090 – 150|
| | | 48HJ008 – 014| 581C090 – 150| PGH090 – 150| DCG090 – 150
| | | 48LJ008 – 014| 580C090 – 150| RGS090 – 150|
| | | 48QJ008 – 014| 580D090 – 150| |
| | | 48TC_08 – 14| 580F090 – 150| |
| | | 48TF008 – 014| 580J08 – 12| |
| | | 48TJ008 – 014| 581J_08 – 12| |
| | | 48TM008 – 014| 581J_04 – 07| |
| | | 48HC_G08-12| | |
| | | 48LC_A07| | |
| | | 48LC_B07| | |
| | | 48TC_E08-14| | |
| | | 48TC_M08-12| | |
Electric/| ECC090-150| ZCA092 – 150| 50DJ008 – 014, 50GJ008 – 012| 551B090 –
150| | PAE090 – 150| CPC090 – 150|
Electirc| | | 50HJ008 – 014, 50HE004 – 006| 558C090 – 150| PAH090 – 150|
DCC090 – 150
| | | 50LJ008 – 014, 50QJ008 – 014| 558D090 – 150| RAS090 – 150|
| | | 50TC_08 – 14, 50LC_04 – 06| 558F090 – 150| |
| | | 50TF008 – 014, 50TJ008 – 014| 558J08 – 12| |
| | | 50TM008 – 014, 50LC_A07| 551J08 – 12| |
| | | 50TC_E08-14, 50TC_M08-12| | |
| | | 50HC_G07-12| | |
Heat Pump| | ZHA092 – 120| 50QJ008 – 012, 50HJQ008 – 012| 549B_X090 – 120| |
PHE090 – 120| CPH090 – 120|
| | 50LJQ008 – 012, 50TCQ_08 – 12| 548B_X090 – 120| PHS090 – 120| DCH090 –
120
| | 50TFQ008 – 012, 50TJQ008 – 012| 548C_X090 – 120| PHH090 – 120|
| | 50HCQD07-09, 50TCQD08-12| 548D_X090 – 120| RHS090 – 120|
| | | 548F_X090 – 120| |
| | | 548J_08 – 12| |
Gas/Electric| GC*180| | 48TJD016, 48TJE016| | | | | YCD180E
| | 48TJF016, 48HJD017| YCD180F
| | 48HJF017, 48TMD016| YSD180F
| | 48TMF016, 48DP016| YHD180F
| | 48DR016| YCD181B
| | | YCD181C
| | | YCD181E
| | | YCD181F
Type
|
Trane
|
Lennox
|
Carrier
|
Bryant
|
JCI/York
|
ICP
Heil
Day and Nigh
|
Goodman Daikin
|
Older Voyager
---|---|---|---|---|---|---|---|---
| GC210| | 48TJD020, 48TJF020| | | | | YCD210A
| 48TMD020, 48TMF020| YCD210B
| 48DP020| YCD210E
| | YCD210F
| | YSD210F
| | YHD210F
| | YCD211B
| | YCD211C
| | YCD211E
| | YCD211F
| GC240| | 48HJD025, 48HJF025| | | | | YCD240A
| 48TJD024, 48TJE024| YCD240B
| 48TJF024, 48TMD025| YCD240E
| | YCD240F
| | YSD240F
| | YHD240F
| | YCD241B
| | YCD241C
| | YCD241E
| | YCD241F
| GC300| | 48TJD028, 48TJE028| | | | | YCD300B
| 48TJF028, 48TMD028| YCD300E
| 48TMF028| YCD300F
| | YSD300F
| | YHD300F
| | YCD301C
| | YCD301E
| | YCD301F
Electric/| GC180| | 50TJ016, 50TM016| | | | | TCD180E
Electric| | 50DP016, 50HJ017| TCD180F
| | | TSD180F
| | | THD180F
| | | TCD181B
| | | TCD181C
| | | TCD181E
| | | TCD181F
Type
| ****
Trane
| ****
Lennox
| ****
Carrier
| ****
Bryant
| ****
JCI/York
| ****
ICP
Heil
Day and Nigh
| ****
Goodman Daikin
| ****
Older Voyager
---|---|---|---|---|---|---|---|---
| GC210| 50DP020| | | | | | TCD210A
| 50TJ020| TCD210B
| 50TM020| TCD210E
| | TCD210F
| | TSD210F
| | THD210F
| | TCD211B
| | TCD211C
| | TCD211E
| GC240| 50TJ024| | | | | | TCD240A
| 50TM025| TCD240B
| 50HJ025| TCD240E
| | TCD240F
| | TSD240F
| | THD240F
| | TCD241B
| | TCD241C
| | TCD241E
| | TCD241F
| GC*300| 50TJ028| | | | | | TCD300B
| 50TM028| TCD300E
| | TCD300F
| | TSD300F
| | THD300F
| | TCD301C
| | TCD301E
| | TCD301F
Trane and American Standard create comfortable, energy efficient indoor
environments for commercial and residential applications. For more
information, please visit trane.com or americanstandardair.com.
Trane and American Standard have a policy of continuous product and product
data improvement and reserve the right to change design and specifications
without notice. We are committed to using environmentally conscious print
practices.
RT-PRC094C-EN 05 Nov 2022 Supersedes RT-PRC094B-EN (Oct 2021)