Technical Specifications
- Product Name: ALD-200 Refrigerant Leak Detector
- Principle: Heated diode detection
- Life of Sensor: Longer compared to traditional leak detectors
- Detection Accuracy: Higher compared to traditional leak detectors
- Operation: Easy to operate
- Refrigerants Detected: Wide range
Detection
Slowly move the probe at a distance of 0.25 inch near the suspected leak area, maintaining a speed of approximately 3 inch/sec.
The ALD-200 Refrigerant Leak Detector is a hand-held leak detector that uses the heated diode detection principle. Compared with the traditional leak detector, its sensor has a longer life, higher detection accuracy, is easier to operate, and can detect a wider range of refrigerants. The ALD-200 has an ergonomic design and a large LCD screen for easy viewing.
Structure
- Flexible probe
- Case
- Probe tip
- USB Port
- Buzzer
- Battery
- Peak
- Leak
- Sensitivity
- Button
Setup
-
Check the device has sufficient battery level. Turn on ( on/off button ) and wait for 30 seconds before testing.
-
Adjust the sensitivity ( sens ).
-
Slowly move the probe ( approx 3 inches/sec ) at a distance of 0.25 inches near the suspected leak area .
-
The screen will show the intensity of the leak and the audible tone will change to a siren sound.
Key Operation
- Detection: When a leak is detected, the screen will show the intensity of the leak and the audible tone will change to a siren sound.
- On/Off button: Press the button for 2 seconds to power on/off the device.
- RSET button: Long press the button for 3 seconds to reset the sensitivity benchmark.
- PEAK button: Press the button to record the maximum value of leakage.
- Sensitivity button: Press the button to adjust sensitivity levels. By default, sensitivity is set to medium.
- MUTE button: Press the button to turn on/off the buzzer.
Specifications
- Sensor type :heated Diode
- Sensor life : 500 hours
- Max sensitivity : 4 g /yr
- Alarm mode: Sound, light and LCD
- Battery: Built-in rechargeable lithium battery 3.7 V 3000 mAh
- Working time: Continuous 6 hours
- Charging time: 4 hours
- Charging current: 5V DC 1A
- Operating environment: -10°C to 52°C /Relative humidity (20% to 85% RH)
- Storage temperature : -20°C to 60°C
- Weight: 415 g
- Dimension: 201x86x38 mm
- Certification: SAE_J1627, SAE_J2791, SAE_J2913, EN14624, 2012 CE Certification
Notices
- Do not submerge the product in water or allow water to enter the intake of the probe.
- Do not expose the product to temperatures exceeding 60°C.
- Do not leave the product in direct sunlight for long periods.
- Do not dismantle or attempt repairs of the product without authorization.
- Do not change or replace the included lithium battery.
- Do not leave for more than 6 months without charging the battery to prevent damage.
- Do not use on objects with a charge or appliances connected to a power source.
- Ensure the filter is present and clean before performing a test.
- Ensure there is enough power before performing a test.
- Use only the supplied charging cable.
- Avoid the inhalation of refrigerant vapor. High concentrations are harmful and may lead to coma or death.
Frequently Asked Questions
- Q: Can I submerge the product in water?
- A: No, do not submerge the product in water or allow water to enter the intake of the probe.
- Q: Can I use the product on objects with a charge or appliances connected to a power source?
- A: No, do not use the product on objects with a charge or appliances connected to a power source.
- Q: What should I do before performing a test?
- A: Before performing a test, ensure that the filter is present and clean. Also, make sure there is enough power before performing a test.
- Q: Can I use any charging cable to charge the product?
- A: No, use only the supplied charging cable to charge the product.
- Q: Is it safe to inhale refrigerant vapor?
- A: No, avoid the inhalation of refrigerant vapor. High concentrations are harmful and may lead to coma or death.
SCANER
Technical Specifications
Video Instruction
https://aprvtiotech.com/
sales@aprvtiotech.com
+1 713 701 1986
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>