Anolis HP111 Ambiane Surface Mount Instruction Manual

June 3, 2024
ANOLiS

Anolis-HP111-Ambiane-Surface-Mount-LOGO

Anolis HP111 Ambiane Surface Mount

INSTALLATION INSTRUCTIONS

AMBIANE HP111 SURFACE MOUNT
  • STEP 1

    • CEILING OPENINGAnolis-HP111-Ambiane-Surface-Mount-01Standard mounting hole with diameter of 100-105mm.
  • STEP 2

    • MOUNTING OF CONTROL UNITAnolis-HP111-Ambiane-Surface-Mount-02Place control unit above the ceiling through the ceiling opening.Anolis-HP111-Ambiane-Surface-Mount-03Mount the control unit to ceiling via two mounting holes and suitable fasteners.
  • STEP 3

    • PRIMARY POWER CONNECTIONAnolis-HP111-Ambiane-Surface-Mount-04Anolis-HP111-Ambiane-Surface-Mount-05
      Install terminal block to power cable (from Ambiance Power Rack or Ambiance Power HP) and connect it to Primary power socket of the control unit.
  • STEP 4

    • DATA CABLES CONNECTION (DMX OR DALI)
      DMX CONNECTION
0V D- D+
Data Ground Data – Data +

Install terminal blocks on DMX or DALI data cables and conne-ct them to the control unit.
Set the DIP switches to positions according to your operation mode. The fixture can be controlled by DMX or DALI (switch 11 in OFF position). Anolis-HP111
-Ambiane-Surface-Mount-07

  • STEP 5
    • SECONDARY POWER CABLE CONNECTION 48V (PSU SCOPE OF OTHERS)Anolis-HP111-Ambiane-Surface-Mount-06Install terminal block on Secondary power cable and connect it to Secondary power socket of the control unit.
  • STEP 6
    • LED UNIT CONNECTION
    1. Shorten power/data cable of LED unit to required length.
    2. Strip these lengths of LED unit‘s cable for wiring connection.
      Anolis-HP111-Ambiane-Surface-Mount-08LED Unit Connection
TERMINAL BLOCK + A B
Color of Wire Red White Blue Black

Anolis-HP111-Ambiane-Surface-Mount-09Install terminal block on LED unit‘s cable and connect it to the control unit .Anolis-HP111-Ambiane-Surface-Mount-10Connected luminaire before installation.
LED unit connected to control unit prior to mounting.

  • STEP 7

    • MOUNTING OF LUMINAIRE
    • Max. possible thickness of a ceiling material is 20 mm. Insert the fixture into the ceiling mounting hole. Spread the holders and tighten them up with Allen key as illustrated.Anolis-HP111-Ambiane-Surface-Mount-13Tighten the holders on both sides until the fixture is firmly se-cured to the ceiling.
      Anolis-HP111-Ambiane-Surface-Mount-14
  • STEP 8

    • INSTALLATION OF ACCESSORIES RING LOUVER FOR 20° REFLECTOR
      Insert the Ring Louver into the Top frame.

ROBE lighting s. r. o. |
Palackeho 416 |
757 01 Valasske Mezirici |
Czech Republic |
Tel.: +420 571 751 500 |
E-mail: [email protected] |
www.anolislighting.com
VERSION 1.0 / 04_2022

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

ANOLiS User Manuals

Related Manuals