PARMIDA PLED-DNEB49W5CCTDIM LED Ultra Thin Ceiling Light 5CCT Gimbal with Junction Box Installation Guide
- June 3, 2024
- PARMIDA
Table of Contents
PARMIDA PLED-DNEB49W5CCTDIM LED Ultra Thin Ceiling Light 5CCT Gimbal with
Junction Box
IMPORTANT:
Please read carefully and save these instructions, as you may need them at a later date. When using electrical equipment, basic safety precautions should always be followed as below:
- Before beginning installation, ensure power is turned off at the main breaker.
- Ensure your eyes are properly protected
GENERAL: All electrical connections must be in accordance with local and National Electric Code (NEC) standards. All electrical connections, installation and service should be performed by a qualified licensed electrician.
READ AND FOLLOW BELOW SAFETY INSTRUCTIONS
To prevent wiring damage or abrasion do not expose wiring to edges of sheet
metal or other sharp objects. Supply conductors (power wires) connecting the
fixture must be rated a minimum 90˚C. If uncertain consult an electrician.
Type IC Rated for direct contact with insulation. This light is dimmable.
Please refer to our website for the most up-to-date compatible dimmer list.
REQUIRED TOOLS: (not included) Safety glasses and gloves, tape measure,
saw, pencil/pen.
UNPACKING: Thoroughly inspect the fixture for freight damage. Freight
damage should be reported to the delivery carrier.
SELECTING COLOR TEMPERATURE
To avoid risk of damage, ensure wall switch connected to the light is turned to off position before changing or selecting desired color temperature (CCT) on the selector switch. Select the color temperature via the CCT switch located on the junction box. Using the color (CCT) selector switch, select the desired color temperature (2700K Warm White, 3000K Soft White, 3500K Neutral White, 4000K Cool White, or 5000K Day Light).
COMPATIBLE DIMMER LIST
DIMMING
Dimming performance may depend on the dimmer, the dimmer range adjustment
setting (for dimmers with brightness range adjustments), the wiring method,
and/or the number of LED modules installed onto the dimmer circuit. For dimmer
selection, Dimming Control Manufacturers revise their product often; for the
latest list of compatible dimmers please visit our website. Please follow the
Dimming Control Manufacturer’s instructions for the installation of all
dimming controls.
NOTE: The table shows dimmers that have been tested and have demonstrated
proper operation under normal conditions. The absence of a dimmer from this
chart does not necessarily imply incompatibility. Please visit our website
www.parmida.com or contact our customer support team
for more details.
LUTRON
- AYCL-153P
- CLDVSL-153P-WH
- CT600P
- CTCL-153P
- DV600P
- DVCL-153P
- IPL06
- MACL-153M
- PD-6WCL
- S600-P
- SCL153P
- TG-10P
- TG600P
- TGCL-153P
LEVITON
- 6674
- 6681
- 1G44I1
- 1PL06
- 6672-1LW
- 6672-DECORA
- DSL06
- DSM10-DECORA
STEPS FOR INSTALLATION
- . RETROFIT: If there is an existing hole, make sure that it is the correct size (3.3in/84mm for 4” model & 5in/127mm for 6” model) for the luminaire to properly fit. If applicable, remove any existing retrofit can.
- NEW INSTALLATION: If there is no existing hole, cut a new hole using the provided hole template. Place the template over the desired location. Trace the outer ring with a pen or pencil (not included). Cut the opening with a saw (not included).
- Open the cover of the remote driver box. Push and remove one of the knockouts on the side plate.
- Locate power supply leads from remote driver box and connect to power source using push connectors (provided).
- Connect black wire to live wire, red wire to neutral wire, and green wire with the ground (as shown) and secure using push connectors. Close the cover of the box.
- Connect the remote driver box to the luminaire and tighten the nut connector by hand.
- Place remote driver box through the cut-out hole. If remote driver box needs to be attached, use provided keyhole fittings on the back of the box to hang it using round head screws (not included).
- Pull the spring clips on the fixture up and through the ceiling hole and place the luminaire in the hole making sure the spring clips are holding securely.
- Turn the power back on. If the luminaire doesn’t illuminate within 5 seconds, turn the power off, carefully remove the luminaire and double-check all wiring.
WARNING
RISK OF FIRE OR ELECTRIC SHOCK DISCONNECT THE MAIN POWER AT THE FUSE OR
CIRCUIT BREAKER BEFORE INSTALLING OR SERVICING THE LIGHT DO NOT PLACE YOUR
HAND UNDERNEATH SPRING CLIPS DURING THE REMOVAL PROCESS. SNAPPING OF THE CLIPS
CAN CAUSE INJURIES TO THE HAND. DO NOT USE ANY OTHER DRIVER EXCEPT PARMIDA
LIGHTING DRIVER THAT IS INCLUDED WITH THE FIXTURE.