PARMIDA 4ft LED T8 Type A+B Tube 3CCT Installation Guide

June 3, 2024
PARMIDA

4FT LED T8 TYPE A+B TUBE – 3CCT
PLED-T818W3CCT-AB-CL
PLED-T818W3CCT-AB-F
INSTALLATION MANUAL

4ft LED T8 Type A+B Tube 3CCT

WARNING

  • Risk of fire or electric shock. When installing with an electronic ballast, please check the compatible ballast list first. If you do not find your ballast on the list, please bypass the fixture. Do not install the LED Tube with a ballast that is not listed on our compatible ballast list – risk of fire.

  • Risk of fire or electric shock. LED Retrofit Kit installation requires knowledge of luminaires electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician.

  • Risk of fire or electric shock. Install this kit only in the luminaires that have the construction features and dimensions shown in the photographs and/or drawings and where the input rating of the retrofit kit does not exceed the input rating of the luminaire.

  • Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.

  • To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.

  • Installers should not disconnect existing wires from lampholder terminals to make new connections at lampholder terminals.
    Instead installers should cut existing lampholder leads away from the lampholder and make new electrical connections to lampholder lead wires by employing applicable connectors.

  • For a linear tubular LED lamp conversion, there shall be text or a diagram showing how the supply connections were made to the lampholders so the correct  onnections will be made to the lamp when the lamp is installed or replaced.

  • This retrofit kit is accepted as a component of a luminaire where the suitability of the combination shall be determined by authorities having jurisdiction.

  • If the tube isinstalled as Type B, the luminaire, once modified as retrofit fixture will no longer operate fluorescent lamps.

  • These lamps should be installed by a licensed electrician.

  • These lamps are to be used indoors (damp or dry locations only). Not suitable for wet location.

  • Under Type A setting this device can be used with compatibleonly non-shunted sockets. emergency ballasts and compatible dimming ballasts (please refer to compatible ballast list).

  • Under Type B setting this device is not suitable for use with emergency ballasts or dimming ballasts.

  • Double-ended connection can be used with either shunted or non-shunted sockets (tombstones). For single-ended connection, use

SELECTING COLOR TEMPERATURE

To avoid risk of damage, ensure wall switch connected to the light is turned to off position before changing or selecting desired color temperature (CCT) on the selector switch.
Select the color temperature via the CCT switch located on the LED lamp’s base. Using this switch, select the desired color temperature (4000K Cool White, or 5000K Day Light, or 6000K Bright White)

“PLUG & PLAY” INSTALLATION (TYPE A)

Before installation, please check our compatible ballast list and ensure your ballast is listed. If it is not listed, please install your LED tubes according to theType B Installation Method instructions below. Parmida is not liable for any damages or losses incurred by not following these instructions.

  1. Disconnect power to the light fixture at the breaker panel before installation.
  2. Remove the diffuser from the light fixture (if applicable).
  3. Remove the existing fluorescent tubes from the light fixture.
  4. Install the LED tubes.
  5. Install diffuser (if removed in step 2).
  6.  Switch on power to the light fixture.

RETROFIT INSTALLATION (TYPE B)

Please install your LED tubes according to the Type B Installation Method instructions below.

  • Can be installed with either single or double ended connection.
  • Double – ended connection can be used with either shunted or non-shunted sockets (tombstones).
  • For single – ended connection, please use non-shunted sockets.
  • Use either end to make single – ended connection.
  1.  Disconnect power to the light fixture at the breaker panel before installation.
  2. Remove the diffuser lens from the light fixture (if applicable).
  3. Remove any existing fluorescent tubes by rotating them a one quarter turn and sliding them out.
  4. Remove ballast cover (cover may be secured with screws or tabs).
  5. Retrofit light fixture according to the diagram applicable to your fixture.

PARMIDA 4ft LED T8 Type A+B Tube 3CCT - 2

A. Retrofit luminaire with inductive ballast

  • Disconnect the wires between starter and ballast according to the figure.
  • Connect two wires to branch circuit L and N according to the figure.

PARMIDA 4ft LED T8 Type A+B Tube 3CCT - 5

B. Retrofit luminaire with electronic ballast

  • Disconnect the wires between tombstone and ballast according to the figure.
  • Connect two wires to branch circuit L and N according to the figure.

PARMIDA 4ft LED T8 Type A+B Tube 3CCT - 7

C. Retrofit luminaire with two lamps and one electronic ballast

  • Disconnect the wires between tombstone and ballast according to the figure.
  • Connect two wires to branch circuit L and N according to the figure.

PARMIDA 4ft LED T8 Type A+B Tube 3CCT - 6

D. Retrofit luminaire with three lamps and one electronic ballast

  • Disconnect the wires between tombstone and ballast according to the figure.
  • Connect two wires to branch circuit L and N according to the figure.

PARMIDA 4ft LED T8 Type A+B Tube 3CCT - 8

E. Retrofit luminaire with four lamps and one electronic ballast

  • Disconnect the wires between tombstone and ballast according to the figure.
  • Connect two wires to branch circuit L and N according to the figure.

PARMIDA 4ft LED T8 Type A+B Tube 3CCT - 9

6. Insert the LED tube by sliding pins into sockets and rotating a quarter turn until the LED tube locks in place.
7. Replace the diffuser lens of the light fixture (if applicable). LED lamps are now fully installed.
8. After installation has been completed, attach the Modification Replacement Cautionary Sticker Label to a visible area on the luminaire and keep it visible after installation. Be sure to mark the type of wiring on the luminaire label (single or double-ended).
9. Restore power to the circuit/luminaire and test the light. If necessary, adjust position of the LED tube(s).

BALLAST COMPATIBILITY LIST: 4FT LED T8 TYPE A+B TUBE – 3CCT

  1. These tubes are compatible with the ballasts listed below. If you intend to install this tube with any ballast not listed below, risk of damage or losses may occur. Parmida is not liable for any damages or losses incurred by not following these instructions.
  2. If you do not see the exact model number of your ballast on this list, it means we have not tested the ballast and cannot guarantee that it will work with our T8 tubes. If this is the case for you, we recommend directly wiring your tubes for the best results.
Brand Model No.
ACT ACT3P32ISUNVE
ACT ATC4P32ISUNVE
DAMAR 1688B
DAMAR 1688D
DAMAR 3654C
EIKO PM-2X32T8-UNV-IS
ESPEN VE232MVHIPLE
ESPEN VE2P32MVHIPE 11068
ESPEN VE2P32MVHIPHE 11069
ESPEN VE332MVHIPLE
ESPEN VE3P32MVHIPE 11070
ESPEN VE3P32MVHIPLE 11056
ESPEN VE4P32MVHIPE 11072
ESPEN VE4P32MVHIPLE 11057
ESPEN VEL-4P32-SC
ESPEN VEL100BN-4C
ESPEN VEL30BN-2C-10V
ESPEN VEL30BN-2C-10V(White)
ESPEN VEL50BN-2C
ESPEN REZ-2S32-SC
ESPEN REZ-3S32-SC
ESPEN VE2P32MVHPPE 11080
ESPEN VE4P32MVHPPE 11086
FULHAM FH12-UNV-1400L-CEC
GE GE132MAX-G-N
GE GE132MAX-H/Ultra
GE GE-132-MV-N
GE GE232-120RES-B
GE GE232MAX-G-N
GE GE232MAX-G-N-DIYB
GE GE232MAXG-N-DIYL
GE GE232MAX-L/ULTRA
Brand Model No.
--- ---
GE GE-232-MV-N
GE GE332MAX-G-H
GE GE332MAX-G-N
GE GE332MAX-G-N-DIYB
GE GE332MAXP-N/ULTRA
GE GE432MAX-G-N
GE GE432MAXG-N-DIYL
GE GE432MAX-L/Ultra
GE GE432MAX-N/Ultra
GE GE432MAXP-L/ULTRA
GE GE132-MVPS-H
GE GE-132-MV-PS-L
GE GE232-MV-PS-H
GE GE232-MVPS-L
GE GE232-MVPS-N
GE GE-232-MV-PS-N
GE GE-232-MVPS-XL
GE GE240RES120-4PK
GE GE240RES120-B
GE GE332-MVPS-L
GE GE-332-MVPS-XL
HALCO EP432IS/L/MV/HE
HALCO EP232IS/MV/HE
HALCO EP332IS/L/MV/HE
HALCO EP332IS/MV/HE
HOWARD EP4/32IS/MV/MC/HE
HOWARD EP2/32IS/MV/MC/HE
HOWARD EPL2/32IS/MV/MC/HE
HOWARD EPL3/32IS/MV/SC/HE
HOWARD EPL4/32IS/MV/MC/HE
KEYSTONE KT-EMRG-1400
KEYSTONE KT-EMRG-500-SL
Brand Model No.
--- ---
KEYSTONE KTEB-232RIS-1-TP-SL/J
KEYSTONE KTEB-232-UV-IS-N-P
KEYSTONE KTEB-332-UV-IS-N-P
KEYSTONE KTEB-432RIS-1-TP-SL
KEYSTONE KTEB-432-UV-IS-N-P
OSRAM SYLVANIA QHE 1X32T8/UNV ISL-SC
OSRAM SYLVANIA QHE 1X32T8/UNV ISN-SC
OSRAM SYLVANIA QHE 2X32T8/UNV ISL-SC-1
OSRAM SYLVANIA QHE 3X32T8/UNV HT-SC
OSRAM SYLVANIA QHE 3XLEDT8/UNV-ISN-SC
OSRAM SYLVANIA QHE 4X32T8/UNV ISN-SC
OSRAM SYLVANIA QHE 4XLEDT8/UNV-ISN-SC
OSRAM SYLVANIA QTP 2X59T8/UNV ISN-SC
OSRAM SYLVANIA QTP 3X32T8/UNV ISN-SC
OSRAM SYLVANIA QTP 4X32T8/UNV ISN-SC
OSRAM SYLVANIA  QHE 3X32T8/UNV-PSN-SC
OSRAM SYLVANIA  QHE 4X32T8/UNV PSX-SC
OSRAM SYLVANIA QHE 2X32T8/UNV PSN-MC
OSRAM SYLVANIA QHE 2X32T8/UNV PSX-MC
OSRAM SYLVANIA QTP 2X32T8/UNV ISN-SC
PHILIPS ADVANCE ICN-1P32-N
PHILIPS ADVANCE ICN-2P32-N
PHILIPS ADVANCE ICN-3P32-N
PHILIPS ADVANCE ICN-4P32-N
PHILIPS ADVANCE IOP-2P32-HL-N
PHILIPS ADVANCE IOP-2P32-LW-N
PHILIPS ADVANCE IOP-2P32-N
PHILIPS ADVANCE IOP-2P59-N
PHILIPS ADVANCE IOPA-1P32-LW-N
PHILIPS ADVANCE IOPA-2P32-LW-N
PHILIPS ADVANCE IOPA-2P32-N
PHILIPS ADVANCE IOPA-3P32-LW-N
Brand Model No.
--- ---
PHILIPS ADVANCE IOPA-3P32-LW-SC
PHILIPS ADVANCE IOPA-3P32-N
PHILIPS ADVANCE IOPA-4P32-LW-N
PHILIPS ADVANCE IOPA-4P32-N
PHILIPS ADVANCE REB-4P32-SC
PHILIPS ADVANCE ICN-2S40-N
PHILIPS ADVANCE IOP-2PSP32-N
PHILIPS ADVANCE IOP-4PSP32-SC
PHILIPS ADVANCE RELB-2S40-N
PLUSRITE BAF232IS/MV
PLUSRITE BAF332IS/MV
PLUSRITE BAF432IS/MV
PLUSRITE BAF232PS/MV
ROBERTSON IEA432T8120N 3P20135
SUNLITE 40155-SU·SB/232/MV
ULTRASAVE UT 232347
UNIVERSAL B232IUNV-C
UNIVERSAL B232IUNVEL-N
UNIVERSAL B232IUNVHEH-A
UNIVERSAL B232IUNVHP-N
UNIVERSAL B332IUNVEL-A
UNIVERSAL B332IUNVHE-A
UNIVERSAL B332IUNVHP-A
UNIVERSAL B432IUNVHE-A
UNIVERSAL B432IUNVHP-A
UNIVERSAL B232PUNVHE-B
UNIVERSAL B432PUNVHE-A

WARNING: Please note that Parmida LLC is not responsible for any problems occurring from installation with any ballast model number not found on our compatible ballast list . Any subsequent issues resulting from installation with a non-listed ballast will not be covered under our warranty.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

PARMIDA User Manuals

Related Manuals