Interaction
Symbol statement
- This appliance is filled with flammable Propane gas R 290. Follow strictly the manufacturer’s instructions concerning use and repairs!
- Before using the machine, carefully read this entire instruction manual.
- Do not install, operate or store the device in a room smaller than 12m²
Technical details
Connected power | 230V~50Hz |
---|---|
Day dehumidification max. | 50 L (30°C RH80%) |
Output capacity | 700 W |
Cooling fluid | R290/0,23kg |
Power usage | 3,7A |
Insolation class | IPX0 |
Dimensions | 53 x 48 x 80 cm |
Weight | 35 kg |
Important safety instructions
General
- Please make sure the power supply is 220-240V~50Hz before operation.
- Please do not plug or unplug to startup or shut off the device, but use the On/Off-button.
- Please do not cut off the power by pulling the wire, but take the plugin your hand.
- Please be careful when moving the device, do not mangle the wire.
- Please do not put a finger, stick, or another object into the grid.
- Please prohibit children to climb, stand or sit on the device, or touching it.
- Please unplug the device before cleaning or maintenance.
- Please do not use the device in a room smaller than 12m².
- If possible, do not use an extension cord, as this poses the risk of overheating and fire. If the use of an extension cord is unavoidable, then make sure it is an undamaged, approved extension cord with a minimum diameter of 3 x 1.5 mm² and a minimum permissible power of 1000 Watt/6 Amp. To prevent overheating, always fully extend the cord!
- Do not use any relay, timer, dimmer, or adapter. Otherwise, it might result in fire, radiation, or electric shock.
- Do not use the device in sunshine, wind, or rain; it is only to use indoors).
- Do not use in places where chemicals or similar can be stored. Volatile substances can damage the device and cause leakage.
- Keep clean the plug and plug it into the socket properly. If the plug is not properly plugged in, the result may be a shock or fire. Never touch the device or plug with wet hands!
- To prolong the life of the filter, pack it in a plastic bag when the device is not used for a longer time.
- Do not place the equipment nearby a stove or heater; otherwise, the weak parts may meltdown and fire may be the result.
- When problems arise (for example a strange smell) switch the device off immediately and unplug it from the wall outlet. Otherwise, a fire, an electric shock or malfunction may result.
- Do not damage the electric cable and replace it never yourself. Do not place heavy objects on the cable and don’t lead it around sharp corners. Keep it away from heat sources. Don’t use a damaged electrical cable anymore!
- When the device is used continuously, arrange a suitable drain. Do not use the device at temperatures around or below freezing point.
- Make sure that the machine is always in a stable and perfectly horizontal position. Otherwise, water may enter into the device and get through to essential elements, with fire, shock, etc. to possible result.
- Do not use the device near water or in spaces such as bathrooms and laundry rooms. If the device is too damp, fire or electric shock may occur.
- When you don’t use the device for an extended period of time, disconnect the plug from the socket.
- Repairs to the appliance, cord, and plug must only be carried out by qualified technicians.
Safety in relation to coolant R290
- This device contains the coolant R290. R290 is a coolant that complies with the relevant European Directives. Never perforate the coolant circuit. R290 is flammable (GWP 3)!
- This device must be used and stored in a room that does not contain sources of ignition, such as open flames or gas and electrical devices in operation.
- Do not perforate any of the components of the cooling circuit and do not set light to the device
- If the device is installed, working, or stored in an un-ventilated you must take measures to prevent fire or explosions caused by leaking coolant. Ensure that there are absolutely no sources of ignition (such as fire, heaters, sparking electrical equipment, lit cigarettes, etc.) in the same room!
- The device must be stored in such a way that mechanical defects are prevented.
- Do not install, operate or store the device in a room smaller than 12m².
- R290 is odorless, which means that you cannot smell leaks!
- Persons working on the cooling circuit must be in possession of the correct qualifications that state the person in question is competent to use coolant in accordance with a special evaluation that is recognized by the sector association.
- The repairs must be executed on the grounds of the recommendations of the manufacturer of the device. Maintenance and repairs that require the assistance of other qualified persons must be executed under the supervision of someone who is specialized in the use of flammable coolant.
- Disassembly and recycling of the device must be performed by a certified technician.
Construction of the device
- Push bar
- Control panel (display)
- Filter
- Handle
- Air inlet
- Air outlet (backside)
- Wheel
- Access to water collection tank + element
The water collection tank is equipped with a water discharge pipe, to which a 1/2 “hose must be connected via the side (by means of a hose clamp). Place the end of the hose in a well, drain or other waste water outlet. Ensure that the hose runs downwards without knicks.
Control panel
1. ON/OFF button
2. Humidity up button
3. Humidity down button
4. Humidity display
5. In operation symbol
6. Water collection tank full symbol
7. Defrosting symbol
8. Fan
9. Hour meter
Starting and operating
-
Make sure that the socket to which you want to connect the dehumidifier has the same voltage as stated on the rating plate: 220-240V ~ 50Hz.
Plug it into the socket; the device beeps. -
Press the on / off button. The display shows the “operating symbol” and the current humidity. When the “in operation symbol” flashes, the humidity is lower than the set humidity.
-
Press the humidity up or humidity down button to set the percentage of the humidity. Each time you press the humidity up and humidity down buttons, you set the desired humidity to 1% higher or lower. If the set humidity is more than 3% lower than the current humidity, the device starts operating until the current value is 3% lower than the set humidity. Then the device turns off.
-
If you set the humidity to less than 30%, the device will continuously dehumidify. The display will then show “CO”.
-
The appliance is equipped with an hour meter, which counts how many hours your appliance has worked in total (in units of 10 minutes).
-
Press the ON/OFF button again in order to switch the device off. The device will come to a halt and the display goes out.
Note:
-
If the set humidity is higher than the actual humidity, the device will not come on.
If you are dehumidifying, the fan motor and the compressor will run for at least three minutes before the compressor starts. The compressor may not be -
When the temperature is low, keep an eye on whether the device needs to defrost. When defrosting, the relevant light will come on and the fan will run but the compressor will automatically switch off.
-
The devices have an automatic memory that automatically stores the settings and also saves if the power supply fails or is interrupted. Once the power supply has been restored, the device will start to work according to the previously entered settings.
-
The display will show a humidity level of 30% to 90%.
-
Remove the plug from the socket if you do not plan to use the device for an extended period.
-
If the water collecting tank is full, the light will come on and the compressor and fan will automatically shut down. You will also hear a beep. If you do not drain the water collection tank, the beep will be repeated every 5 minutes. Only once the water collection tank has been emptied can the device be used again.
-
You can install a continuous drain by removing the water collection tank, taking the rubber bung out on the side of the water collection tank and connecting a hose to this outlet. Then replace the water collection tank and run the hose from the device (downwards) to a suitable drainage point.
-
In order to avoid damaging the compressor, never place the dehumidifier on a slope of over 45°.
The device works between 5°C and 32°C. -
When being used, the compressor will emit heat which can increase the ambient temperature by between 1 and 3°C. This is perfectly normal.
If the indoor temperature is lower than 10°C and air humidity is pretty low, you will not need to use the device. -
Ensure that there is at least 10 cm of free space between the air inlet and the outlet opening and any solid objects, e.g. a wall.
Try to ensure that the room is as well sealed as possible in order to improve the dehumidification result.
Cleaning
Too much dust on the filter will impact the device’s ability to dehumidify. Clean the filter regularly (at least once a month); if the device is placed in a dusty environment, you should clean it weekly or even daily. To do so, open the front panel and take the filter (1) out. Remove the loose dust by carefully knocking the filter. Then vacuum the filter gently or wash it in lukewarm water with a little, mild soap. Leave to dry thoroughly before repositioning in the device (follow the above instructions in reverse order). Never use the dehumidifier without a filter! If also the element (2) is dirty, you can clean it carefully with a brush, see fig. The housing and the water reservoir can be cleaned with a damp cloth and a mild cleaning agent. Never use corrosive or abrasive products as these could damage the finish. Always remove the plug from the socket before carrying out any cleaning work!