APsystems 2300532 25A AC Connector EN 3-Wire Installation Guide
- June 3, 2024
- APsystems
Table of Contents
APsystems 2300532 25A AC Connector EN 3-Wire
Tools
Cross screwdriver, wire striper, solid wrench or monkey wrench .
INSTALLATION INSTRUCTIONS
-
Step 1. Verify the AC connector:
Type is 25A AC Male Connector (EN,3-wire) or 25A AC Female Connector (EN,3-wire). -
Step 2. Wire Stripping
-
Wire gauge :3×2.5mm²~4mm² (or 14AWG~12AWG)
-
Cable OD :10mm~12mm
-
Wire stripping size ( mm ) :Earth wire is supposed to be longer than Live wire and Neutral wire
-
Step 3. Install the AC connectors
-
Set the parts on the cable according to the order of 1→2→3→4.
-
Crimp wires : the plastic core of connector is printed, please wire according to the print, screw twisting torque 0.8 +/_0.1N.m .
-
Push Housing into Body until hear the the click sound.
-
Insert Seal and Clamp Finger into Body, then tighten the nut, torque
-
Installation of cable end female connector is the same as male connector
NOTE:
- If the microinverter’s output is L,N,PE, the wiring method is:
- Connector Power Grid
- L L
- N N
- PE PE
- If the microinverter’s output is L,L,N, the wiring method is:
- Connector Power Grid
- L L
- N L
- PE N
APsystems
8701 N. Mopac Expy, Ste 160, Austin, TX 78759 Tel :
844-666-7035
apsystems.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>