Uheat 006-OCT23 Underfloor Heating Solutions User Guide

June 1, 2024
uheat

Uheat 006-OCT23 Underfloor Heating Solutions

Underfloor Heating Solutions Guide

About us
Uheat is a trading style of Pedarson Ltd (The Pedarson Group), a wholly family-owned and managed company established in 2003.

Our business ethos from the very start has been (and always will be) based on offering the highest standards of customer service, together with a range of products that meet our stringent demands for utmost quality and value for money. Here at Uheat, we pride ourselves on our approach to customer service and every time you contact us, you can expect to receive professional and friendly advice.
Uheat specialises in the supply of electric and water underfloor heating, radiators and fittings, plumbing accessories and frost protection solutions.
Our extensive range of underfloor heating / frost protection products can provide solutions for virtually any type of project. Whether it be a complete new build, renovation/refurbishment or extension.

Uheat-006-OCT23-Underfloor-Heating-Solutions- \(1\)

ELECTR IC UNDERFLOOR HE ATING

Uheat-006-OCT23-Underfloor-Heating-Solutions- \(2\)

MD

Uheat-006-OCT23-Underfloor-Heating-Solutions- \(3\)

Notes

  • Insulation is optional underneath the heating mats but it will reduce the warmup time and reduce running costs so it should always be used if possible.
  • If the floor finish is tiles, then you can either use flexible tile adhesive directly on the heating mat or self-level over the heating mat then fix the tiles with flexible tile adhesive.
  • If you’re going to use MD heating mats under wood, vinyl or carpet, then you will need to use a levelling compound over the mat before installing the floor finish.

THE FOUNDATION OF YOUR WETROOM
[email protected]
01394 593300

WATERPROOFING & TILING ESSENTIALS
[email protected]
01394 330929

MODERN & TRADITIONAL HEATING SOLUTIONS
[email protected]
01394 330920Uheat-006-OCT23-Underfloor-Heating-Solutions-
\(4\)

Notes

  • Insulation should be rigid PIR
  • Some insulation / screed combinations require a vapour barrier to be installed directly on the insulation before you install the cable and lay the screed.
  • To comply with building regulations, you should use a minimum 65mm sand / cement screed or 50mm pumped screed.

Uheat-006-OCT23-Underfloor-Heating-Solutions- \(5\)

Notes

  • It is essential that a 6mm XPS insulating underlay, such as Izotherm, is used under the WoodTec heating mats.
  • Your laminate or engineered wood flooring can be laid directly WoodTec system without the need for any other underlay.
  • The thermal resistance of your floor covering (Carpet + Underlay) should not exceed 2.5 TOG.

Notes

  • You must use flexible tile adhesive to secure the HeatBase mat to the floor and to fix the tiles on top of the heating cable / HeatBase mat
  • As you are using Heatbase, you will not need any other decoupling membrane.

WATER UNDERFLOOR HE ATING

Uheat-006-OCT23-Underfloor-Heating-Solutions- \(8\)

Notes
Insulation is typically rockwool but rigid insulation can be used.

Uheat-006-OCT23-Underfloor-Heating-Solutions- \(9\)

Notes

  • Insulation should be rigid PIR
  • Some insulation / screed combinations require a vapour barrier to be installed directly on the insulation before you install the pipe and lay the screed.
  • To comply with building regulations, you should use a minimum 65mm sand / cement screed or 50mm pumped screed.

Uheat-006-OCT23-Underfloor-Heating-Solutions- \(10\)

Notes

  • Insulation should be rigid PIR
  • Some insulation / screed combinations require a vapour barrier to be installed directly on the insulation before you install the pipe and lay the screed.

Uheat-006-OCT23-Underfloor-Heating-Solutions- \(11\)

Notes

  • Insulation should be rigid PIR
  • Some insulation / screed combinations require a vapour barrier to be installed directly on the insulation before you install the pipe and lay the screed.
  • To comply with building regulations, you should use a minimum 65mm sand / cement screed or 50mm pumped screed.

Uheat-006-OCT23-Underfloor-Heating-Solutions- \(12\)

Notes

  • Vinyl & Carpet flooring requires 6mm self-levelling compound
  • Please check manufacturers approval when using tile adhesive.

Uheat-006-OCT23-Underfloor-Heating-Solutions- \(13\)

Notes
Ad-Chip Chipboard will require oboarding with 6mm plywood before installation of floor finishes

Uheat-006-OCT23-Underfloor-Heating-Solutions- \(14\)