APsystems 2300932202 25A AC Connector Installation Guide

May 15, 2024
APsystems

APsystems 2300932202 25A AC Connector

APsystems 2300932202 25A AC Connector

Installation Instructions

(For USA)

Tools: Cross screwdriver, wire striper, solid wrench or monkey wrench .
Step 1. Verify the AC connector: Type is 25A AC Male Connector (EN,3-wire) or25A AC Female Connector (EN,3-wire).

  • 25A AC Male Connector(EN,3-wire)
    Installation Instructions

  • 25A AC Female Connector(EN,3-wire)
    Installation Instructions

Step 2. Wire Stripping

Wire gauge: 3×2.5mm²~4mm² (or 14AWG~12AWG)
Cable OD: 10mm~12mm
Wire stripping size ( mm ): Earth wire is supposed to be longer than Live wire and Neutral wire.

Wire Stripping

Step 3. Install the AC connectors

a. Set the parts on the cable according to the order of 1→2→3→4.

Installation Instructions

b. Crimp wires: the plastic core of connector is printed, please wire according to the print,screw twisting torque 0.8 + /- 0.1N . m .

Install the AC connectors 

  • 25A AC Male Connector

  • 25A AC Female Connector

NOTE: ①If the microinverter’s output is L,N,PE, the wiring method is:
②If the microinverter’s output is L,L,N, the wiring method is:

Connector Power Grid
L L
N N
PE PE

Connector Power Grid
L L
N N
PE N

c. Push Housing into Body until hear the the click sound.

Install the AC connectors

d. Insert Seal and Clamp Finger into Body, then tighten the nut, torque 4.0+/-0.5N.m

Install the AC connectors

  • Installation completed
    Install the AC connectors

e. Installation of cable end female connector is the same as male connector.