FRANKE FDPA 904 XS LED0 Cooker Hood Instruction Manual
- June 12, 2024
- Franke
Table of Contents
FDPA 904 XS LED0 Cooker Hood
Instruction Manual
SAFETY INFORMATION
For your safety and correct operation of the appliance, read this manual
carefully before installation and use. Always keep these instructions with the
appliance even if you move or sell it. Users must fully know the operation and
safety features of the appliance.
The wire connection has to be done by specialized technician.
-
The manufacturer will not be held liable for any damages resulting from incorrect or improper installation.
-
The minimum safety distance between the cooker top and the extractor hood is 650 mm (some models can be installed at a lower height, please refer to the paragraphs on working dimensions and installation).
-
If the instructions for installation for the gas hob specify a greater distance, this must be respected.
-
Check that the mains voltage corresponds to that indicated on the rating plate fixed to the inside of the hood.
-
Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules.
-
For Class I appliances, check that the domestic power supply guarantees adequate earthing.
-
Connect the extractor to the exhaust flue through a pipe of minimum diameter 120 mm. The route of the flue must be as short as possible.
-
Regulations concerning the discharge of air have to be fulfilled.
-
Do not connect the extractor hood to exhaust ducts carrying combustion fumes (boilers, fireplaces, etc.).
-
If the extractor is used in conjunction with non-electrical appliances (e.g. gas burning appliances), a sufficient degree of aeration must be guaranteed in the room in order to prevent the backflow of exhaust gas. When the cooker hood is used in conjunction with appliances supplied with energy other than electric, the negative pressure in the room must not exceed 0,04 mbar to prevent fumes being drawn back into the room by the cooker hood.
-
The air must not be discharged into a flue that is used for exhausting fumes from appliances burning gas or other fuels.
-
If the supply cord is damaged, it must be replaced from the manufacturer or its service agent.
-
Connect the plug to a socket complying with current regulations, located in an accessible place.
-
With regards to the technical and safety measures to be adopted for fume discharging it is important to closely follow the regulations provided by the local authorities.
WARNING: Before installing the Hood, remove the protective films. -
Use only screws and small parts in support of the hood.
WARNING: Failure to install the screws or fixing device in accordance with these instructions may result in electrical hazards. -
Do not look directly at the light through optical devices (binoculars, magnifying glasses…).
-
Do not flambe under the range hood; risk of fire.
-
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
-
Children should be supervised to ensure that they do not play with the appliance.
-
The appliance is not to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction.
Accessible parts may become hot when used with cooking appliances. -
Clean and/or replace the Filters after the specified time period (Fire hazard). See paragraph Care and Cleaning.
-
There shall be adequate ventilation of the room when the range hood is used at the same time as appliances burning gas or other fuels (not applicable to appliances that only discharge the air back into the room).
-
The symbol on the product or on its packaging indicates that this product may not be treated as household waste. Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. For more detailed information about recycling of this product, please contact your local city office, your household waste disposal service or the shop where you purchased the product.
CHARACTERISTICS
Dimensions
Components
Ref. | Q.ty | Product Components |
---|---|---|
1 | 1 | Hood Body. complete with: Controls, Light, Blower, Filters |
2 | 1 | Telescopic Chimney comprising: |
2.1 | 1 | Upper Section |
2. | 1 | Lower Section |
9 | 1 | Reducer Flange 0 150-120 mm |
14.1 | 2 | Air Outlet Connection Extension |
15 | 1 | Air Outlet Connection |
30 | 1 | Lower corner spacer |
Ref. | Q.ty | Installation Components |
---|---|---|
7.1 | 1 | Hood Body Fixing Bracket |
7.2.1 | 4 | Upper Chimney Section Fixing Brackets |
7.3 | 1 | Air Outlet Connection Support |
11 | 18 | Wall Plugs |
12a | 18 | Screws 4,2 x 44,4 |
12c | 6 | Screws 2,9 x 9,5 |
12e | 6 | Screws 2,9 x 9,5 |
Q.ty | Documentation |
---|---|
1 | Instruction Manual |
INSTALLATION
Wall drilling and bracket fixing
- Rest Bracket 7.1 as shown, 960 mm above the cooker top, taking care that the bracket is level.
- Mark the wall at the centres of the holes in the bracket.
- Rest a Bracket 7.2.1 as shown, 1-2 mm from the ceiling or top limit, and 347 mm from the corner of the wall.
- Mark the wall at the centres of the holes in the bracket.
- Place bracket 7.2.1 on the wall as shown at X mm below the first bracket (X = height of the upper chimney section supplied), and 347 mm from the corner of the wall.
- Repeat this operation on the other side, checking that it is level.
- Drill ø 8 mm holes at all the centre points marked.
- Insert the wall plugs 11 in the holes.
- Fix the brackets and the Support using the 12a (4,2 x 44,4) screws supplied.
To install the hood in recycling version it is necessary to follow the
instructions described in the part concerning Recirculation version Air
Outlet.
Fitting the Hood Canopy
Before fixing the Hood to the wall, Lower corner spacer 30 must be connected
to the Hood Canopy as follows:
- Loosen the 2 Screws that join the elements making up a Lower corner spacer 30.
- Fasten the Lower corner spacer 30 to the Hood using 3 Screws (2.9 x 9.5) provided.
- Adjust the Screws Vr, located on the Hood Canopy connection points, so that they are at the half-way point.
- Hook the Hood Canopy to the Bracket provided.
- It is now possible to level the hood canopy, using the screws Vr.
- Lock the 2 Screws in the Lower corner spacer, loosened as above, after moving the mobile part until it is in the right position.
- If necessary, it is possible to fasten the hood to the wall using two more screws with wall plugs, which can be positioned from inside the hood canopy.
Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the chimney using
either a flexible or rigid pipe ø 150 or 120 mm, the choice of which is left
to the installer.
- To install a ø 120 mm air exhaust connection, insert the reducer flange 9 on the hood body outlet.
- Fix the pipe in position using sufficient pipe clamps (not supplied).
- Remove possible charcoal filters.
RECIRCULATION VERSION AIR OUTLET
- Insert the extension pieces 14.1 laterally on the air outlet connection piece 15.
- Fix the connection piece with the extension pieces onto the support 7.3 using the two screws 12e (2,9 x 9,5) provided.
- Place the assembled unit on the wall corner at 110 mm from the ceiling or upper limit.
- Mark the centre of the bracket holes.
- Drill the marks ø 8 mm.
- Insert wall plugs 11 into the holes.
- Fix the connection piece using the screws 12a (4,2 x 44,4) provided.
- Make sure that the charcoal filter has been mounted inside the hood.
ELECTRICAL CONNECTION
- Connect the hood to the mains through a two-pole switch having a contact gap of at least 3 mm.
- Remove the grease filters (see paragraph Maintenance) being sure that the connector of the feeding cable is correctly inserted in the socket placed on the side of the fan.
Chimney assembly
Upper exhaust Chimney
- Slightly widen the two sides of the upper chimney and hook them behind the brackets 7.2.1, making sure that they are well seated.
- Secure the sides to the brackets using the 4 screws 12c (2,9 x 9,5) supplied.
Lower exhaust Chimney
- Slightly widen the two sides of the chimney and hook them between the upper chimney and the wall, making sure that they are well seated.
- Fix the lower part laterally to the hood body using the 2 screws 12c (2,9 x 9,5) supplied.
USE
L | Light | Switches the lighting system on and off. |
---|---|---|
S | Led | Motor running led. |
V1 | Motor | Switches the extractor motor on and off at low speed. Used to |
provide a continuous and silent air change in the presence of light cooking
vapours.
V2| Speed| Medium speed, suitable for most operating conditions given the
optimum treated air flow/noise level ratio.
V3| Speed| Maximum speed, used for eliminating the highest cooking vapour
emission, including long periods.
MAINTENANCE
Grease filters
CLEANING METAL SELF- SUPPORTING GREASE FILTERS
- The filters must be cleaned every 2 months of operation, or more frequently for particularly heavy usage, and can bewished in a dishwasher.
- Remove the filters one at a time holding them up with one hand and pulling the handle downwards with the other hand at the same time.
- Wash the filters, taking care not to bend them. Allow them to dry before refitting.
- When refitting the filters, make sure that the handle is visible on the outside.
Activated charcoal filter (Recirculation version)
These filters are not washable and cannot be regenerated, and must be replaced
approximately every 4 months of operation, or more frequently with heavy
usage.
REPLACING THE ACTIVATED CHARCOAL FILTER
- Remove the metal grease filters
- Remove the saturated activated charcoal filter as shown (A).
- Fit the new filters (B).
- Replace the metal grease filters.
Lighting unit
- For replacement contact technical support (“To purchase contact technical support”).
Franke S.p.a.
Via Pignolini,2
37019 Peschiera del Garda (VR)
www.franke.it
991.0529.913_03 – 220314
D000000004116_02 ****
References