Whitecroft lighting Trimpak / Trimpak Vitality Instruction Manual

June 3, 2024
Whitecroft lighting

Trimpak / Trimpak Vitality

Installation Instruction

PK-TRIMPAK-IL                                                   Sept 2022 – Rev B

Whitecroft Lighting Limited

Burlington Street, Ashton-under-Lyne, Lancashire OL7 0AX
Telephone +44 (0)161 330 6811     Facsimile: +44 (0)1616 331 5855
Registered No. 3848973 England       Registered Office: As above

1200/1500 Luminaire Fixing Centres 600mm

Whitecroft lighting Trimpak A03

1800 Luminaire Fixing Centres 1200mm

Whitecroft lighting Trimpak A03

  1. Conduit mounts
  2. BESA mounts/cable entry points
  3. This product has provisions for additional suspension for safety located here
VERSION L(mm) H(mm) W(mm) WEIGHT(kg) WEIGHT EM (kg)
1200 1160 78 59 1.9 2.5
1500 1440 78 59 2.3 2.9
1800 1719 78 59 2.7 3.3
1200 sensor 1302 78 59 2.3 2.7
1500 sensor 1582 78 59 2.7 3.1
1800 sensor 1861 78 59 3.1 3.5

1. Remove product from packaging and check for damage.
2. Remove body using a screwdriver as leverage through access point in both endcaps. Then detach earth and safety cords and place in clean area. If conduit mounting remove knock outs from endcaps using pliers.

Whitecroft lighting Trimpak A05

Whitecroft lighting Trimpak A06

3. Attach body to ceiling, spine or trunking surface and feed in cable. For conduit fold down mounting points. Fixings supplied by others.
4. Offer up diffuser assembly and suspend from safety cords then connect earth lead.
5. Connect all electrical connections to the terminal blocks. See layout below.

STANDARD VARIANTS

STANDARD DALI VARIANTS

EMERGENCY VARIANTS

EMERGENCY DALI /EMERGENCY COMEPS

EMERGENCY COMEPS DALI VARIANTS

N- NEUTRAL
E- EARTH
L/L1- SWITCHED LIVE
L2- PERMANENT LIVE
DALI EM- DALI EMERGENCY

6. If the luminaire is an emergency variant, connect the battery leads and mark the installation date.
7. Press diffuser assembly back into body starting at non sensor end if applicable. Locking feature in endcap must be inside in canopy notch. Ensure no cables or safety cords are trapped and both endcaps are fully engaged.

Whitecroft lighting Trimpak B06

  1. Canopy notch
  2. Locking feature
SPECIFICATION:
Lamp type: LED
Output: 2000/3000/4000/5500/ 7000/11000lm nominal.
Colour: 4000°K – Ra80
Materials:
Body: RAL 9003 White painted mild steel
Diffuser: Polycarbonate (OPAL)
Control gear: Fixed output / DALI
Emergency: Integral 3hr / COMEPS
Supply: 220-240v 50/60Hz AC
Ambient Temperature: 0-25°C
Terminal block type: Push-wire / piano-key max cable size 2.5mm²
Ingress protection: IP20
Wattage: Refer to datasheet

Electrostatic
Sensitive Device

High Voltagle
LED’s

GENERAL INFORMATION
  1. A qualified electrician, in accordance with IEE wiring regulations should carry out connection to mains wiring.
  2. Observe ESD precautions during installation.
  3.  This unit must be EARTHED.
  4. Ensure that the rated voltage and frequency requirements are compatible with the available mains supply.
  5. Cleaning of reflectors and lenses should be carried out using clean, soft and lint free cloths and anti-static cleaning fluid
  6. Do not carry out high voltage insulation test, i.e. 500/1000v this may damage internal components.
  7. Luminaire body will become hot under normal operating conditions. Allow to cool before undertaking any necessary maintenance work.
FURTHER INFORMATION

TECHNICAL SUPPORT
Telephone: 0161 331 5700
E-mail: [email protected]
http://www.whitecroftlighting.com/

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Whitecroft lighting User Manuals

Related Manuals