Whitecroft lighting Trimpak / Trimpak Vitality Instruction Manual
- June 3, 2024
- Whitecroft lighting
Table of Contents
Trimpak / Trimpak Vitality
Installation Instruction
PK-TRIMPAK-IL Sept 2022 – Rev B
Whitecroft Lighting Limited
Burlington Street, Ashton-under-Lyne, Lancashire OL7 0AX
Telephone +44 (0)161 330 6811 Facsimile: +44 (0)1616 331 5855
Registered No. 3848973 England Registered Office: As above
1200/1500 Luminaire Fixing Centres 600mm
1800 Luminaire Fixing Centres 1200mm
- Conduit mounts
- BESA mounts/cable entry points
- This product has provisions for additional suspension for safety located here
VERSION | L(mm) | H(mm) | W(mm) | WEIGHT(kg) | WEIGHT EM (kg) |
---|---|---|---|---|---|
1200 | 1160 | 78 | 59 | 1.9 | 2.5 |
1500 | 1440 | 78 | 59 | 2.3 | 2.9 |
1800 | 1719 | 78 | 59 | 2.7 | 3.3 |
1200 sensor | 1302 | 78 | 59 | 2.3 | 2.7 |
1500 sensor | 1582 | 78 | 59 | 2.7 | 3.1 |
1800 sensor | 1861 | 78 | 59 | 3.1 | 3.5 |
1. Remove product from packaging and check for damage.
2. Remove body using a screwdriver as leverage through access point in both
endcaps. Then detach earth and safety cords and place in clean area. If
conduit mounting remove knock outs from endcaps using pliers.
3. Attach body to ceiling, spine or trunking surface and feed in cable. For
conduit fold down mounting points. Fixings supplied by others.
4. Offer up diffuser assembly and suspend from safety cords then connect
earth lead.
5. Connect all electrical connections to the terminal blocks. See layout
below.
STANDARD VARIANTS
STANDARD DALI VARIANTS
EMERGENCY VARIANTS
EMERGENCY DALI /EMERGENCY COMEPS
EMERGENCY COMEPS DALI VARIANTS
N- NEUTRAL
E- EARTH
L/L1- SWITCHED LIVE
L2- PERMANENT LIVE
DALI EM- DALI EMERGENCY
6. If the luminaire is an emergency variant, connect the battery leads and
mark the installation date.
7. Press diffuser assembly back into body starting at non sensor end if
applicable. Locking feature in endcap must be inside in canopy notch. Ensure
no cables or safety cords are trapped and both endcaps are fully engaged.
- Canopy notch
- Locking feature
SPECIFICATION:
Lamp type: | LED |
---|---|
Output: | 2000/3000/4000/5500/ 7000/11000lm nominal. |
Colour: | 4000°K – Ra80 |
Materials: | |
Body: | RAL 9003 White painted mild steel |
Diffuser: | Polycarbonate (OPAL) |
Control gear: | Fixed output / DALI |
Emergency: | Integral 3hr / COMEPS |
Supply: | 220-240v 50/60Hz AC |
Ambient Temperature: | 0-25°C |
Terminal block type: | Push-wire / piano-key max cable size 2.5mm² |
Ingress protection: | IP20 |
Wattage: | Refer to datasheet |
Electrostatic
Sensitive Device
High Voltagle
LED’s
GENERAL INFORMATION
- A qualified electrician, in accordance with IEE wiring regulations should carry out connection to mains wiring.
- Observe ESD precautions during installation.
- This unit must be EARTHED.
- Ensure that the rated voltage and frequency requirements are compatible with the available mains supply.
- Cleaning of reflectors and lenses should be carried out using clean, soft and lint free cloths and anti-static cleaning fluid
- Do not carry out high voltage insulation test, i.e. 500/1000v this may damage internal components.
- Luminaire body will become hot under normal operating conditions. Allow to cool before undertaking any necessary maintenance work.
FURTHER INFORMATION
TECHNICAL SUPPORT
Telephone: 0161 331 5700
E-mail: technical@whitecroftlight.com
http://www.whitecroftlighting.com/
References
Read User Manual Online (PDF format)