Whitecroft lighting Mirage 3 Ceiling Light Instruction Manual

June 1, 2024
Whitecroft lighting

Whitecroft lighting Mirage 3 Ceiling Light

Whitecroft-lighting Mirage-3-Ceiling-Light-product-
image

Product Information

Specifications :

  • Model: Mirage 3
  • Compatible Models: C79, C110, C165, SQ165, Nightingale M3
  • Manufacturer: Whitecroft Lighting Limited
  • Address: Burlington Street, Ashton-under-Lyne, Lancashire OL7 0AX
  • Telephone: +44 (0)161 330 6811
  • Website: www.whitecroftlighting.com

Product Usage Instructions

  1. Inspection and Preparation:
    Open the packaging and wear disposable gloves to prevent skin contact with the reflector surface. Check for any damage during transit.

  2. Aperture Preparation:
    Use appropriate tools to prepare the aperture based on the dimensions provided. Ensure proper clearance from walls, insulation, and driver/EM box.

  3. Wiring :
    Wire the product to mains according to the provided wiring diagrams. For emergency products, follow specific instructions for connecting the battery.

  4. Installation:
    Install the product in the ceiling carefully, ensuring proper alignment and avoiding damage to the ceiling during the process.

  5. Maintenance :
    To remove the fitting for maintenance, use clean gloves to protect the product. Carefully detach the product from the ceiling using a flat-bladed screwdriver.

Frequently Asked Questions (FAQ):

  • Q: How do I access the battery on the C165 and SQ165 models?
    A: The battery on these models is accessed via a separate cover on the gear box lid as shown in figure 4 in the manual.

  • Q: What is the clearance required around the downlighter?
    A: Ensure 100mm clearance from the downlighter in all directions to walls/insulation and driver/EM box as shown in figure 2 in the manual.

  • Q: How should I wire emergency products?
    A: For emergency products, follow the wiring diagram provided in figure 5 in the manual and ensure proper connection of the battery as shown in figures 7 and 8.

Mirage 3

Installation Instructions
C79 / C110 / C165 / SQ165 & Nightingale M3

Whitecroft-lighting Mirage-3-Ceiling-Light-fig- \(1\)

INSTALLATION DETAILS

  1. Open packing and locate the disposable gloves, this is to stop grease from skin contact getting onto the reflector surface. These must be worn throughout the installation.
  2. Inspect the contents of the box for any damage in transit.
  3. Prepare aperture using appropriate tool, circular fittings are based around standard size hole saws. See Dimensions on last page for cut sizes.
  4. Ceiling thickness is show under Product and Driver Dimensions. See fig 1.
  5. Check void dimensions. Ensure 100mm clearance from the down lighter is given in all directions to walls/insulation and driver/EM box. See Fig.2. Insulation cannot directly cover the back of the down lighter.Whitecroft-lighting Mirage-3-Ceiling-Light-fig- \(3\)
  6. If attachments are required these are ordered separately and will be assembled next. They are only available on C165 –IP44 products. See the attachments list on last page. To assemble twist the bezel anti-clockwise to release as shown in fig.3. Then place the required attachment into the bezel and twist clockwise to lock. If the down lighter is an EM version take care that the EM LED indicator attached to the bezel is not over stressed. This can be easily removed with a flat bladed screw driver if needed. Please remember to re attached when finished.Whitecroft-lighting Mirage-3-Ceiling-Light-fig- \(4\)
  7. For standard F/O, DALI and Tuneable white products. Wire product to mains by removing the cable restraint cover from driver. Trim back Mains/Dali cabling 10-11mm and wire directly to driver. See last page for cable details.
  8. For emergency products remove 2 x Pozi drive screws and retain the paint breaking washer see fig.4. Wire mains to product following the fig.5 wiring diagram. Note if driver and inverter are required to run on the same DALI pair then use the link kit provided and wire as fig.6. Once complete replace the lid and paint breaking washer and screws. The paint breaking washer is required for earthing purposes. Access to battery on C165 & SQ165 is via cover as fig.4Whitecroft-lighting Mirage-3-Ceiling-Light-fig- \(5\)
  9. Note: Nightingale M3 requires controls for full functionality (See fig.5) Whitecroft-lighting Mirage-3-Ceiling-Light-fig- \(6\)
  10. Install product in ceiling. If this is an emergency product connect the battery fig.7 or fig.8 and fill in the commissioning date on the label. The battery on the C165 round and SQ165 square products is accessed by separate cover on the gear box lid fig.4. For the C79 and C110 round products the battery is external. Carefully place the product through the aperture in the following order external battery/Steel box/ external driver. Ensure the process does not damage the ceiling.
  11. Pull back springs on body and carefully offer up to and through the cut aperture see fig.10, again be careful not to catch the ceiling during this process. Ensure fingers are clear before releasing spring to avoid injury. Ensure the fitting is centered in the aperture.
  12. Nightingale Orientation
  13. To remove the fitting for maintenance, first ensure clean gloves are used to protect fitting from dirt and grease. Then place a flat bladed screw driver carefully behind the bezel and ceiling to open up a gap. Use fingers to grip the product and pull down. You can also use your free hand to ease the spring through the aperture to stop damage to the ceiling.

SPECIFICATION

  • Lamp type: LED
  • Output: 500lm, 1000lm, 2000lm, 3000lm, 4000lm (Nominal + Tuneable White) size specific (check website)
  • Colour: 3000k/4000K RA80/90 & Tuneable White
  • Materials Acrylic Diffuser
    Polycarbonate Reflector (Specular, Semi Specular, White RAL 9010 or Black RAL
  1. Graphite Composite Heatsink
  • Supply 220-240V, 50/60Hz
  • Operating temp 0˚c to 25˚c
  • Power Refer to Whitecroft Lighting Website for full list of power information. (See bottom)
  • Connection Terminal block/Driver 0.75mm² to 1.5mm², 10-11mm stripped
  • Ingress: IP44/65 (from below)
  • Protection
  • Attachments: MA3-FLO, MA3-CYL, MA3-DIFF (Only available on C165 – IP44 products)
  • Tuneable Note this product requires DALI type 8 controls in order to output the tunable
  • White: colour control. (Supplied separately or by others)

PRODUCT AND DRIVER DIMENSIONS

| Ceiling| Cut Aperture| | EM|
---|---|---|---|---|---
Version| Ø (mm)| H (mm)| Depth (mm)| CAØ ± 1mm| | KG| KG| Driver(mm)
C79| 87| 79| 1-40| 79| 0.5| 1.5| 53(W ),| 30(H), 121(L)
C110| 118| 102| 1-50| 110| 1.0| 1.5| 53(W ),| 30(H), 121(L)
C165| 173| 106| 1-50| 165| 1.0| 2.0| 67(W ),| 30(H), 140(L)
SQ165| 173sq| 110| 1-50| 165sq| 1.0| 2.0| 67(W ),| 30(H), 140(L)
Nightingale M3| 173| 144| 1-50| 165| 1.0| 2.0| 42(W ),| 30(H), 97(L)
C165 Tuneable| 173| 106| 1-50| 165| 1.0| 2.0| 70(W ),| 31(H), 215(L)
SQ165 Tuneable| 173sq| 110| 1-50| 165sq| 1.0| 2.0| 70(W ),| 31(H), 215(L)

Whitecroft-lighting Mirage-3-Ceiling-Light-fig- \(9\)

EMERCENCY BOX DIMENSIONS

Version| W (mm)| H (mm)| L (mm)| EM Box| Battery Dims(mm)| Driver Dims(mm)
---|---|---|---|---|---|---
C79| 69| 40| 227| Small| 70(W ), 34(H), 152(L)| 53(W ), 30(H), 121(L)
| | | | LiFEPO| 50(W ), 41(H), 126(L)|
C110| 69| 40| 227| Small| 70(W ), 34(H), 152(L)| 53(W ), 30(H), 121(L)
| | | | LiFEPO| 50(W ), 41(H), 126(L)|
C165| 145| 80| 236| Large| N/A| N/A
SQ165| 145| 80| 236| Large| N/A| N/A
Nightingale M3| 145| 80| 236| Large| N/A| N/A

*Small EM box has separate remote battery and driver.
**Included inside large EM box

Whitecroft-lighting Mirage-3-Ceiling-Light-fig- \(10\)

GENERAL INFORMATION

  1. A qualified electrician, in accordance with IET wiring regulations should carry out connection to mains wiring.
  2. Observe ESD precautions during installation.
  3. Emergency versions of this luminaire must be earthed
  4. Ensure that the rated voltage and frequency requirements are compatible with the available mains supply.
  5. Cleaning of reflectors and lenses should be carried out using clean, soft and lint free cloths. Use of cleaning fluids can mark reflector surfaces.
  6. Do not carry out high voltage insulation test, i.e. 500/1000v this may damage internal components.
  7. For secondary suspension points please refer to fig.13. The holes are design to accommodate steel cable (supplied by others).Whitecroft-lighting Mirage-3-Ceiling-Light-fig- \(11\)
  8. Allow sufficient time for product to cool before performing maintenance. Heatsink may be hot.
  9. The light source contained in this luminaire shall only be replaced by the manufacturer or a designated service agent or a suitably qualified person.
  10. Batteries used in emergency versions of this luminaire range are replaceable by a qualified electrician.

TECHNICAL SUPPORT

Telephone: 0161 331 5700
E-mail: [email protected]
http://www.whitecroftlighting.com/

Whitecroft Lighting Limited
Burlington Street, Ashton-under-Lyne, Lancashire OL7 0AX
Telephone +44 (0)161 330 6811 Facsimile: +44 (0)161 331 5855
www.whitecroftlighting.com
Registered No. 3848973 England

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Whitecroft lighting User Manuals

Related Manuals