ANOLiS Eminere Remote UV2, UV4 productFOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE POWERING OR INSTALLING YOUR Eminere Remote UV ! Save it for future reference.
This device has left our premises in absolutely perfect condition. In order to maintain this condition and to ensure safe operation, it is absolutely necessary for the user to follow the safety instructions and warnings written in this manual. The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unauthorized modification to the device. Unauthorized modification will void warranty.

 Safety instructions

THIS LUMINAIRE IS DESIGNED WITH UV LEDS AND MUST BE INSTALLED IN COMPLIANCE WITH COMPETENT TECHNICAL DIRECTIONS TO PREVENT THE USER’S EYE AND BARE SKIN FROM EXPOSURE TO HARMFUL UV RADIATION.
CE LUMINAIRE EST CONCU POUR ETRE UTILISE AVEC DES LED UV ET DOIT ETRE INSTALLE EN STRICTE CONFORMITE AVEC LES INSTRUCTIONS AFIN D’EVITER QUE LES YEUX OU LA PEAU L’UTILISATEUR NE SOIENT EXPOSES AUX EFFETS NEFASTES DES RAYONS UV.
CAUTION:
Radiation exposure may cause blindness and cancer of skin!

Maximum exposure time (minutes) – beam angle 120°

Distance from UV source| Eminere Remote UV 2| Eminere Remote UV 4
0.8m (2.6ft)| 18| –
1m (3.3ft)| 28.2| –
1.5m (4.9ft)| 63.4| 31.7
2m (6.6ft)| 112.7| 56.4
3m (9.8ft)| 253.6| 126.8
4m (13ft)| 450.8| 225.4
5m (16.4ft)| 704.4| 352.2
6m (19.7ft)| 1014.4| 507.2
7m (23ft)| 1380.7| 690.3
8m (26ft)| 1803.3| 901.7
9m (29.5ft)| 2282.3| 1141.2
10m (32.8ft)| 2817.7| 1408.8

DANGEROUS VOLTAGE CONSTITUTING A RISK OF ELECTRIC SHOCK IS PRESENT WITHIN THIS UNIT!
Always disconnect the fixture from power before cleaning, servicing or installing. The fixture was designed for outdoor use. This fixture must not be used for underwater installation. When choosing the installation spot, please make sure that the fixture is not exposed to extreme heat or dust. Do not install the unit near an open flame. Avoid using the unit in locations subject to possible impacts. The fixture body never must be covered with cloth or other materials when the fixture is under operation. Only operate the fixture after having checked that the housing is firmly closed and all screws are tightly fastened. The fixture becomes hot during operation. Allow the fixture to cool approximately 30 minutes prior to servicing or maintenance. Operate the fixture only after having familiarized yourself with its functions. Do not permit operation by persons not qualified to operate the fixture. Immunity of the equipment is designed for electromagnetic environments E1, E2, E3 according to the standard EN55103-2 ed.2 Electromagnetic compatibility. Product family standard for audio, video, audiovisual and entertainment lighting control apparatus for professional use. Part 2: Immunity.
The product (covers and cables) must not be exposed to a high frequency electromagnetic field higher than 3V/m. The installation company should check levels of possible interferences above the tested levels E1,E2,E3 given by this standard (e.g. transmitters in surrounding area) before installing the equipment. Emission of the equipment complies with the standard EN55032 Electromagnetic compatibility of multimedia equipment – Emission Requirements according to class B. Please consider that unauthorized modifications on the fixture are forbidden due to safety reasons!
Please use the original packaging if the fixture is to be transported.
If this device will be operated in any way different to the one described in this manual, the product may suffer damages and the warranty becomes void. Furthermore, any other operation may lead to dangers like short-circuit, burns, electric shock etc. Refer servicing to qualified service personnel.

 Fixture exterior view

ANOLiS Eminere Remote UV2, UV4 01

  1. Transparent glass cover
  2. Gore tex valve
  3.  Cable gland M20 (IN)
  4. Housing
  5. Mounting brackets
  6.  Cable gland M20 (OUT)
  7. Junction box

Installation

 Mounting the fixture

The Eminere Remote UV can be arranged in any orientation on a flat, non- flammable surface by means of two mounting brackets (5) which can be tilted by 30°. ANOLiS Eminere Remote UV2, UV4 02

Connection to driver

The unit must be installed by a qualified electrician in accordance with all national and local electrical and construction codes and regulations. The Eminere Remote UV modules should be connected to the E-Box Remote or E-Box Remote basic as stated in the chapter “Technical specifications“.
Example of connection ANOLiS Eminere Remote UV2, UV4
03The table below states max. number of Eminere Remote UV modules connected to the E-box Remote/E-box Remote Basic.

| Max. number of Emineres Remote UV connected to the E-box Remote/E-box Remote Basic
---|---
**Cable length *| Eminere Remote UV 2| Eminere Remote UV 4**
25 m| 10| 5
50 m| 8| 4
75 m| 6| 3
100 m| 5| 2

  • Cable length is a total cable length between E-box Remote (E-box Remote Basic) and last connected Eminere Remote UV.

Example: Total cable length=L1+L2+L3+L3ANOLiS Eminere Remote UV2, UV4
04Max. number of Eminere Remote UV modules connected to the one output of the E-box Remote/E-box Remote Basic is stated in the following table.

Max. number of Emineres Remote UV connected to the one output of the E-box Remote/E-box Remote Basic

Eminere Remote 2| Eminere Remote 4
8| 4

Example: if you want to connect 10 Emineres Remote UV 2 to the E-box Remote, you may connect 8 Emineres Remote UV 2 to the output 1 and 2 Emineres Remote UV 2 to the output 2 (at total cable length of 25 m).

 Wiring of the junction box
  1. Unscrew the four screws (9) on the cover (8) of the junction box (7), remove the cover (8) and the gasket (10).

  2. Remove the end cap (11) from cable glands before passing cables throw cable glands M20 (3,6).
    The cable glands M20x1.5 can be used for cables of a diameter of 7-13mm.

  3.  Pass the power/data cables through the cable glands (3,6) and connect them to the connection blocks (12, 13).

  4.  Place the See their gasket (10) on the junction box (7) and screw the cover (8) to the junction box (7).
    Check that all cable glands (and blind flange) and screws are firmly secured.

After checking all connections, fill the junction box with synthetic resin. Make sure that the End cap is inserted in unused cable gland before filling it. At filling of the junction box proceed according instructions stated on the bag of the resin. The connection blocks have to be fully poured in the resin.ANOLiS Eminere Remote UV2, UV4 05Wiring of connection blocks (12,13) in the junction box. ANOLiS Eminere Remote UV2,
UV4 06CE version

Connector + D+ D- ****
Function LEDs + Data + Data – LEDs – Ground
Colour of wire Red Orange Black White Not connected

US version

Connector + D+ D- ****
Function LEDs + Data + Data – LEDs – Ground
Colour of wire Red Orange Black White Green

To keep declared IP rating of the fixture, every cable gland has to be covered with the end cap (11) if the cable gland is not used for cable passing. We recommend to apply an adequate layer of the paste LOCTITE 5331 on the plastic holder of the cable gland before inserting it into the body of the gland and an adequate layer of the paste LOCTITE 577 on the thread of the body of gland (if the cable gland was screwed out).ANOLiS Eminere Remote UV2, UV4
07

Technical specifications

Power supply

  •  Input voltage: 48 V
  • Power consumption:

Eminere Remote UV 2: 40W
Eminere Remote UV 4: 80W
Optic

  • Light source:
    Eminere Remote UV 2: 16 x UV LEDs
    Eminere Remote UV 4: 32 x UV LEDs

  •  UV LEDs Wave Length: 365nm

  • Beam Angle: 38°, 120°

Compatible drivers

  • E-box Remote, E-box Remote Basic

Mounting method

  • Via two L-shape brackets with adjustment range 30°

Housing

  • Aluminium extruded body
  •  Tempered glass

Cooling system

  • Convection

Total heat dissipation

  • Eminere Remote UV 2: 102 BTU/h (calculated)
  • Eminere Remote UV 4: 205 BTU/h (calculated)

Weight

  • Eminere Remote UV 2: 3.1 kg (6.83 lbs)
  • Eminere Remote UV 4: 5.1 kg (11.24 lbs)

Dimensions (All dimensions in mm [inch]) ANOLiS Eminere Remote UV2, UV4
08Protection factor

  • CE: IP 67
  •  US: Suitable for wet location

Impact rating

  • CE: IK06

Operating ambient temperature range

  • -20°C /+40°C (-4°F /+104°F)

Operating temperature

  • +67°C @ Ambient +40°C (+153°F @ Ambient +104°F)

Connection

  • 5-cored cable

Included items

  • 1 x Eminere Remote UV
  •  1 x User manual
Optional accessories
  • Mounting Bracket 50
  •  Mounting Bracket 100
  • Mounting Bracket 200
  • Mounting Bracket 300
  •  Mounting Bracket- Custom length
  • Shield For Eminere Remote 2
  •  Shield For Eminere Remote 4

 Cleaning and maintenance

DANGER !
Disconnect from the mains before starting any maintenance or cleaning work
Rinse off loose dirt with low pressure water spray. Wash the housing with a soft brush or sponge and a mild, non-abrasive washing detergent. Rinse it. Maintenance and service operations are only to be carried out by a qualified person. Should you need any spare parts, please use ROBE OEM parts.

 Disposing of the product

To preserve the environment please dispose or recycle this product at the end of its life according to the local regulations and codes.

Change Log

This section summarizes changes in the user manual.

Version of the manual Date of issue Description of changes

Documents / Resources

| ANOLiS Eminere Remote UV2, UV4 [pdf] User Manual
Eminere Remote UV2, Eminere Remote UV4, Eminere Remote, Eminere, Remote
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals