ANOLiS Arcsource Outdoor 24MC Integral Installation Guide
- June 3, 2024
- ANOLiS
Table of Contents
ANOLiS Arcsource Outdoor 24MC Integral
INSTALLATION INSTRUCTIONS
| Fixture must be installed by a qualified electrican in accordance with all
national and local electrical
and construction codes and regulations. This device falls under class one and
must be grounded!|
---|---|---
Use an Allen key 6 to release M8 tilting lock on each side of luminaire and
adjust tilt of LED module in range of +35°/-90°.
STEP 1A
MOUNTING – USING YOKE
1
Mount the fixture via suitable mounting holes. Ensure that you are mounting
the fixture to a secure and non-flammable surface.
| Use fasteners that are appropriate for use with your mounting surface.|
---|---|---
**2**
Fasten the Yoke of the fixture to the surface by three screws.
STEP 1B
MOUNTING – USING FLOOR STAND
Floor stand.
| Use fasteners that are appropriate for use with your mounting surface.|
---|---|---
1
Mount the floor stand to the surface via 4 mounting holes of 9mm or 7mm in
diameter.
**2**
Mount the luminaire to the Floor stand as illustrated on picture above and
fasten it by nut with washer to bolt on floor stand.
ArcSource Outdoor 24MC Integral mounted on the Floor stand.
STEP 1C
MOUNTING – USING LAND SPIKE
100 MM / 130 MM
Land spike 100mm and land spike 130mm.
Insert the Land Spike into ground. Underground part of Land Spike should be
placed perpendicularly into the ground. (if you need to use tools to insert
spike in the ground, use of some protective layer, and applying pressure in
the middle is recommended to prevent damaging of land spike)
2X M8x20
Mount the luminaire to the Land spike as illustrated on picture above and
fasten it by two screws M8x20 with washers and spring washers.
Arc Source Outdoor 24MC Integral mounted on the Land Spike.
STEP 1D
MOUNTING – USING TENON ADAPTOR
DIAMETER 63 – 80 MM / 80 – 106 MM
Tenon Adaptor 63 – 80 mm and Tenon adaptor 80 – 106 mm
1
Slide the Tenon Adaptor (mortise) of suitable size on a tenon (e.g. top of a metal post) and fasten in with three screws included in the adapter.
2
2X M8x25
Mount the luminaire to the Tenon Adaptor as illustrated on picture above and
fasten it by two screws M8x25 with washers and spring washers.
ArcSource Outdoor 24MC Integral mounted on the Tenon Adaptor.
STEP 1E
MOUNTING – USING POLE CLAMP
DIAMETER 63 – 80 MM / 80 – 105 MM
1
Disassemble the Pole Clamp by unscrewing both nuts from bolts.
2
Mount the Pole Clamp to a pole and fasten it by screwing both nuts with
washers back to its bolts. Adjust the Pole Clamp to ensure its correct
position before tightening it completely..
**3**
When in correct position, tighten both nuts completely.
**4**
2X ****M8x25
Place the luminaire to the Pole Clamp as illustrated on picture above and fasten it by two screws M8x25 with washers.
ArcSource Outdoor 24MC Integral mounted on each side of Pole Clamp.
STEP 2
CONNECTION
Single luminaire connection. Connect DMX IN and Power cable to a Junction box
and Power/data cable from the Junction box to the luminaire.
Multiple luminaire connection.
Use power/data cable for connection between Junction boxes as illustrated on
picture bellow. Notice the change of connection between first two and all
following junction boxes of the daisy chain line.
1
Removing the Cover of Junction Box
4X M4x20
Open the Junction Box by unscrewing 4 M4x20 screws and lifting up the cover.
2
Install Housing
| Use fasteners that are appropriate for use with your mounting surface.|
---|---|---
Mount the Junction Box to a surface via two mounting holes and suitable
fasteners.
3
**Strip these lengths for wire connections
**
4
Connection – colour coding
Power Connection – Power IN
| L| N| GROUND
Core (EU)| Brown| Blue| Green/Yellow
Core (US)| Black| White| Green
DMX CONNECTION
0 V | D- | D+ |
---|---|---|
Data Ground | Data – | Data + |
Cable CE/US Leader – LED Output
WIRE
| DATA AND POWER CONNECTION
---|---
Brown| Live
Blue| Neutral
Yellow/Green| Ground
Red| +
White| –
Shielding| 0
A
Power Connection | 9 mm |
---|---|
Data Connection | 7 mm |
**5A**
EU color code shown Connection scheme for the installations of single luminaire.
5B
Wiring connection – Daisy chain – First Junction Box
EU color code shown Connection scheme for the first Junction Box in daisy
chain line
5C
Wiring connection – Daisy chain – Following Junction Bo
EU color code shown Connection scheme for each following Junction Box in daisy chain line. Only power/data cables are used.
6
Cable gland installation
Use wrench size 24 for cable gland M20x1.5 Install Cable glands individually!
Apply Loctite 5331 thread sealant on the plastic holder and Loctite 577 thread locking compound on the gland body in the indicated locations prior to assembly
Failure to properly install cable glands will result in failure of the water tight seal!
7
Close junction box
4X 2 Nm
Install safety cover and top cover back.
Before applying the torque, make sure the thread is clean and functional.
STEP 3
INSTALLATION ACCESSORIES
**Top Hat and Half Top Hat. (Identical installation instructions)
**
1
4X M6x12
Unscrew 4 M6x12 screws from rear side of the luminaire as highlighted on picture above.
**2**
Slide the accessory on the luminaire from a side.
3
**
4X M6x12
** Fasten the accessory to the rear side of luminaire with four M6x12 screws and spring washers.
**4**
ArcSource Outdoor 24MC Integral with Half Top Hat.
**1**
2X ****M6x12
Unscrew two M6x12 screws from the rear side of luminaire as highlighted on a picture above.
**2**
Slide the Optical demo set on the luminaire.
3
**
2x M6x12
Fasten the accessory to the rear side of luminaire with two original screws
and washers.
` 4**`
Slide an optical foil into Optical demo set.
Arc Source Outdoor 24MC Integral with Optical demo set.
ROBE lighting s. r. o. | Palackeho 416 | 757 01 Valasske Mezirici | Czech
Republic | Tel.: +420 571 751 500 | E-mail: info@anolis.eu |
www.anolislighting.com
VERSION 2.0 / 02_2022
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>