DELTA BX6.3_DD Battery Storage System Installation Guide

June 3, 2024
Delta

DELTA BX6.3_DD Battery Storage System

DELTA BX6.3_DD Battery Storage System-fig1

BX6.3_DD user manual
For more instruction and specification, please scan QR-code to see user manual.
Battery > BX6.3_DD Operation and Installation Manual
https://mydeltasolar.deltaww.com/?p=product_manual

Descriptions of Components

DELTA BX6.3_DD Battery Storage System-fig2

Object Qty Description
Delta BX6.3_DD 1
Quick Installation Guide

(English)

|

1

| The Instruction to provide the information of safety, installation and specification.
③| Communication connector| 1| Connector for inverter communication board
④| Rubber cover| 1| Protective cover for non-critical waterproof and dust prevent
⑤| Plastic cover| 4
⑥| H4 Wrench| 2| To disconnect H4 connector
⑦| H4 Connector| 2 pair| Connector for inverter
⑧| Wiring Cover| 1| Protective cover to prevent users from touching the power cable
⑨| Japanese Manual *| 2| User manual and Quick install guide in Japanese

  • Japanese manual is only intended for Japanese market.

LED Indicators

LED Status Definition
GREEN FLASH Standby mode
ORANGE ON Charge
GREEN ON Discharge
RED FLASH Boot up / Shut down
RED ON BMS error
RED & GREEN FLASH ALTERNATELY Programming

Push Button

Status Operation Action

BX6.3_DD power OFF

| Power button push > 20 sec (until grid green LED flash)| Power ON the unit (Cold start-up)
BX6.3_DD power ON already| Power button push >1 sec| Power OFF the unit
Warning

 |

Do not open this product or insert tools due to shock and fire hazard which may cause injury.

 |

The following instructions must be adhere when installing:

● The product is intended to be installed and operated by qualified personnel or service personnel only.

●  Do not power up the device before installation is complete.

● All circuit breakers must be in the OFF position before commencing

installation.

 | ●  Do not install BX6.3_DD near or on flammable surfaces.

●  Please mount BX6.3_DD tightly on a solid / smooth surface.

●  Install BX6.3_DD in a location that prevents damage from flooding.

● Do not expose BX6.3_DD to ambient temperatures above 60°C or below -20°C.

● Operating or storing BX6.3_DD in temperatures outside its specified range might cause damage to BX6.3_DD.

60 seconds

|

Danger to life through electric shock

Potentially fatal voltage is applied to the unit during operation. Voltage persists 60 seconds after disconnection of power supply. Never open the unit. The unit contains no components that must be maintained or repaired by the operatoror installer.

Opening the housing will void the warranty.

Dimensions and Interface Overview

Installation

  • Please refer to regulation AS/NZS 5139:2019 for detail installation space requirement. To avoid extra fireproof cement sheeting installation requirement, it is recommended to keep at least 300mm between the wall and BX.

Insert Rawlplug

DELTA BX6.3_DD Battery Storage System-fig6

  1. Drill 4 holes with Φ16 mm diameter in dimension 540mm x 220mm.
  2. Insert Rawlplugs into the holes.
  3. Fix the foot of BX6.3_DD firmly.
  4. Tighten the nut to stretch the rawlplug.

Wiring

DELTA BX6.3_DD Battery Storage System-fig8

Conduit hole(mm) PF pipe(mm)
Φ 34 Φ 28
Φ 27 Φ 22

Inverter connection

Specification

Model BX6.3_DD BX6.3_DD+BX6.3_EX100

GENERAL
Enclosure| Aluminum with powder coating
Operating temperature| -10℃ * ~ 45℃
Operating Altitude| 0 to 2000m (0 to 6666 ft.)
Relative humidity| 0% – 95% non-condensing.
Environmental category| Indoor / Outdoor
Protection degree| IP65 (Electronics)
Pollution degree| PD 2
Overvoltage category| Other: not connected to mains directly
Galvanic isolation| NO
Safety class| Class I metal enclosure with protective earth
Weight| 75kg| 75 kg (BX6.3_DD)

+ 60 kg (BX6.3_EX)

Dimensions(WHD)| 570 × 840 × 250 mm| 570 × 840 × 250 mm

+ 520 × 600 × 230 mm

Connectors| Weather resistant connectors
Audible noise| < 40dB
BT INPUT
Type| Li-ion
Battery Module| Samsung SDI 41J (21700)
Typical Energy| 6.3 kWh| 12.6 kWh
Typical Voltage| DC 202.7 V| DC 405.4 V
Voltage Range| DC 175 – 228 V| DC 350 – 456 V
Depth of Discharge (DoD)| 98%
DC BUS INPUT / OUTPUT
Nominal power| 3000 W| 6000 W
Maximum power| 3000 W| 6000 W
Voltage| 250V – 1000V
Maximum input/ output current| 15.6 A| 15.6 A
Maximum fault current| 25A
Tare loss| < 10 W
Maximum efficiency| 99%
REGULATIONS & DIRECTIVES
Electrical safety| IEC 62619:2017, IEC 60730-1:2013