DELTA ITG70BT Ventilation Fan with Bluetooth Speaker User Manual

June 3, 2024
Delta

DELTA ITG70BT Ventilation Fan with Bluetooth Speaker

DELTA ITG70BT Ventilation Fan with Bluetooth Speaker

PACKAGE CONTENTS

DELTA ITG70BT Ventilation Fan with Bluetooth Speaker-1

PART DESCRIPTION QTY
1 Fan Housing 1
2 Grille 1
3 Duct Connector 1
4 Bluetooth Speaker Assembly 1

GENERAL SAFETY INFORMATION

READ AND SAVE THESE INSTRUCTIONS
GENERAL SAFETY INFORMATION

  1. Make sure that the electric service supply voltage is AC 120V, 60Hz.
  2. Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the Occupational Safety and Health Act (OSH Act).
  3. Always disconnect the power source before working on or near the ventilating fan, motor or junction box.
  4. Protect the power cord from sharp edges, oil, grease, hot surfaces, chemicals or other objects.
  5. Do not kink the power cord.
  6. shown in Fig.A.
  7. Provide suction parts with proper ventilation.
  8. This unit is UL Listed for use over a bathtub or shower when installed in a GFCI-protected branch circuit.
  9. These ventilating fans are intended for residential usage only.
  10. This product is designed for ceiling installation only. Do not mount this product in a wall.

WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

  1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
  2. Before servicing or cleaning the unit, switch the power off at the service panel and lock the service disconnecting means to prevent the power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
  3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
  4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating Refrigeration and Air Conditioning Engineers (ASHRAE) and local code authorities.
  5. When cutting or drilling into the wall or ceiling, do not damage electrical wiring and other hidden utilities.
  6. Ducted ventilating fans must always be vented to the outdoors.
  7. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI (Ground Fault Circuit lnterrupter) – protected branch circuit.
  8. Do not use this unit with any other solid-state control device. Solid-state controls may cause harmonic distortion, which can cause a motor humming noise.
  9. NEVER place a switch where it can be reached from a tub or shower.
  10. Not to be installed in a ceiling thermally insulated to a value greater than R50. (This is required for installation in Canada only).

CAUTION

  1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
  2. Not for use in cooking areas. (Fig. B)
  3. This product must properly connect to the grounding conductor of the supply circuit.
  4. To reduce the risk of injury to persons, install the fan at least 8.2 feet (2.5m) above the floor.

FCC COMPLIANCE
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radion communications.
However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different bfrom that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for bhelp.

FCC ID: H79VFRU-19-32BT
The Bluetoothword mark and logos are registered trademarks
Owned by Bluetooth SIG, Inc. and any use of such marks by
Delta Electronics, Inc. is under license. Other trademarks and trade names are those of their respective owners.
The Bluetooth speaker complies with FCC radiation exposure limits set forth for an uncontrolled environment. End users must follow the specific operating instructions for satisfying exposure Compliance. This speaker must not be co- located or operate conjuction with any other antenna or transmitter. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.

NOTE: The Grantee is not responsible for any changes or modifications not expressly approved by the party responsible for compliance. Such modifications could void the user’s authority to operate the equipment.

PREPARATION

Tools Required for Assembly (not included): Hammer,Flathead Screwdriver, Wire Nuts, Nails, Duct Tape,Phillips Head Screwdriver, Utility Knife Helpful Tools (not included): Electric Drill, Drill Bits

WARNING: Turn off electricity at breaker box before beginning installation.
Carefully remove unit from carton.
Check area above installation location to be sure that wiring can run to the planned location and that duct proper ventilation.
Inspect duct work and wiring before proceeding with installation.
Before installation, provide inspection and future maintenance access at a location that will not interfere with installation work.
You may need the help of a second person to install this fan: one person on the attic side and one on the room side.

Note: Installations may vary depending on how the previous bath fan was installed. Supplies necessary for the installation of your bath fan are not all included.
However, most are available at your local home improvement or hardware store.

Proper insulation around the fan to minimize building heat loss and gain. 4” circular duct is recommended for installation. The ducting from this fan to the outside of building has a strong effect on the air flow, noise and energy use of the fan. Use the shortest, straightest duct routing possible for best performance, and avoid installing the fan with smaller ducts than recommended.
Insulation around the ducts can reduce energy loss and inhibit mold growth. Fans installed with existing ducts may not achieve their rated air flow.

  • The fan will operate most efficiently when located where the shortest possible duct run and minimum number of elbows will be needed.
  • Use a roof cap or wall cap that has a built-in damper to reduce backdrafts.

DIMENSION REQUIREMENTS

Housing

Dimension (L)

| Housing

Dimension (W)

| Housing

Dimension (H)

---|---|---
7 1/2 in.| 7 1/4 in.| 5 3/4 in.

WIRING DIAGRAM

DELTA ITG70BT Ventilation Fan with Bluetooth Speaker-5

ASSEMBLY INSTRUCTIONS

NEW CONSTRUCTION

BEFORE INSTALLATION
Turn off power source. Review all safety precautions.

  1. Attach the duct connector 3 to the fan housing 1.

  2. Remove the wiring box cover fro m the fan housing 1 . Remove the wiring knockout from the wiring box cover with a flathead screwdriver (not included).DELTA ITG70BT Ventilation Fan with Bluetooth Speaker-6

  3. Place the fan housing 1 next to a ceiling joist or wall stud, The fan housing should be level and perpendicular to the joist or stud.

  4. Mount the fan housing 1 to the joist or stud using nails (not included) where indicated.

  5. Pull the wire through the hole and into the junction box (not included), secure 120VAC house wiring from the wall switch to the fan as shown in the wiring diagram on page5. 14AWG is the smallest conductor that shall be used for branch-circuit wiring.
    Push the wires back through the hole. Reattach the wiring box cover.

  6. I nstall a circular 4 in. duct (not included) and secure it with duct tape or clamps (neither included).
    Finish ceiling work. The ceiling hole should be aligned with the edge of the fan housing.

  7. Plug the Micro USB connector into the speaker assembly 4 , and secure the speaker assembly to the holder on the fan unit.DELTA ITG70BT Ventilation Fan with Bluetooth Speaker-8

  8. Pinch the mounting springs on the grille 2 ,and insert them into the narrow rectangular slots inside the fan. Push the grille up toward the ceiling.
    Turn on electricity at the breaker box after finishing installation.

EXISTING CONSTRUCTION BEFORE INSTALLATION
Turn off power source. Review all safety precautions.

  1. Remove existing fan.

  2. Measure the opening to ensure it is large enough to accommodate the new fan body (7 1/2 in. x 7 1/4 in.).
    Note: 7 1/4 inch side of opening should be flush with the joist.

  3. I f this fan is not replacing an old fan, be sure to cut a 7 1/2 in. x 7 1/4 in. opening for the fan housing 1 . Make sure the 7 1/4 inch side of opening is flush with the joist for installation from below.

  4. Attach the duct connector 3 to the fan housing 1 .

  5. Remove the three screws that hold the fan motor assembly in place. Remove the fan motor assembly from the fan housing 1 . Unplug fan and speaker connector.

  6. Pull the wire through the hole and into the junction box (not included), secure 120VAC house wiring from the wall switch to the fan as shown in the wiring diagram on page5. 14AWG is the smallest conductor that shall be used for branch-circuit wiring.
    Push the wires back through the hole. Reattach the wiring box cover.

  7. I nstall a circular 4 in. duct (not included) and secure it with duct tape or clamps (neither included).

  8. Insert the fan housing through the existing hole in the ceiling. The fan housing should be level and perpendicular to the joist or stud.

  9. Mount the fan housing to the joist or stud using nails (not included) where indicated by arrows inside the fan housing.DELTA ITG70BT Ventilation Fan with Bluetooth Speaker-12

  10. Plug the fan assembly back into the fan housing.Reattach the fan assembly using the thress screws removed in step 5.

  11. Plug the Micro USB connector into the speaker assembly 4, and secure the speaker assembly to the holder on the fan unit.

  12. Pinch the mounting springs on the grille 2, and insert them into the narrow rectangular slots inside the fan.
    Push the grille up toward the ceiling.
    Turn on electricity at the breaker box after finishing installation.

OPERATION

Fan Mode:
Turn the Fan switch to operate ON/OFF.
Speaker Mode: (Bluetooth speaker model:VFRU-19-32BT)
Turn the Speaker switch to operate ON/OFF.
Pairing your Bluetooth device to the speaker for the first time

  1. To play your personal music or audio files, you need a Bluetooth device, like smart phone, tablet, or any other such devices.
  2. Place the Bluetooth device located within 32 feet of the fan.
  3. Set your device to midrange volume before connecting to the speaker.
  4. Turn ON the Speaker switch, the blue LED indicator flashes in pairing mode.
  5. Follow the instructions that came with your Bluetooth device to make it discoverable or to set it to search for other Bluetooth accessories. This may involve entering a passkey or PIN( Personal ldentification Number).
  6. From the home screen, tap Settings > Bluetooth, the device searches and a list of discoverable devices will appear, choose “DeltaBreez ITG”, and enter a passkeyn or PIN (0000) if prompted.
  7. When pairing is completed, the blue LED indicator will solid on, you can use the Bluetooth speaker to play music or audio files with your device.

CARE AND MAINTENANCE

See safety information before proceeding. Routine maintenance should be done at least once a year.

  • Never use solvents, thinner or harsh chemicals when cleaning the fan.
  • Do not allow water to enter the motor.
  • Do not immerse metal parts in water.
  • Do not immerse resin parts in water over 140º Fahrenheit.
  • Do not immerse Bluetooth speaker in water.

Turn off power source. Review all safety precautions.

  1. To remove grille 2 , squeeze springs and pull down.
  2. Wash and clean the grille 2 in a sink and dry with a cloth.
  3. Remove dust and dirt from the fan housing 1 with a vacuum cleaner.
  4. Dampen cloth with dust detergent and wipe the fan housing 1. Then wipe dry with a clean cloth.
  5. Replace grille 2 back onto fan housing 1
  6. Turn on power source to operate fan again.

TROUBLESHOOTING

PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION

The fan is not turning on

| ****

1. Power off

2. Faulty switch

3. Faulty wire connection

| ****

1. Make sure power supply is on.

2. Test or replace switch.

3. Check wire in switch box.


The fan seems louder than it should

| ****

1.  CFM too great


2.  Damper not working properly or damaged


3.  Bend in duct too close to fan discharge

4.  Fan discharge

duct

5.  Fan body not securely attached

| 1.  Be sure the CFM rating on the fan matches the size of your room.

2.  Check damper to ensure it is opening and closing properly. If the damper has become damaged, please call Customer Service.

3.  Be sure you do not have any sharp bends in duct closer than 18 in. to the fan discharge.

4.  Use recommended size ducting to reduce fan noise.

5.  Be sure the fan is securely attached to your ceiling joists.

The fan is not clearing the room| 1.

airfow within room


| 1.  Be sure a door or window is slightly ajar or opened


2.  Be sure the CFM rating on the fan matches the requirements for your room size.

DIMENSIONS

DELTA ITG70BT Ventilation Fan with Bluetooth
Speaker-16

UNIT: INCH

PRODUCT SPECIFICATIONS

DELTA ITG70BT Ventilation Fan with Bluetooth
Speaker-17

Note: Design and specifications subject to change without notice.

WARRANTY

DELTA ELECTRONICS THREE YEAR LIMITED WARRANTY
Delta Electronics Inc. (“Delta Electronics”) warrants to the original consumer purchaser in the USA and Canada that the Breez ventilation fan products will be free from defects in material or workmanship. This warranty is limited to three (3) years from the original date of purchase.

Limitations and Exclusions

  1. During the warranty period, a replacement for any defective product will be supplied free of charge for installation by the consumer. The warranty provided herein does not cover charges for labor or other costs incurred in the troubleshooting, repair, removal, and installation service.
  2. All returns of defective parts or products must include the product model number, and must be made through an authorized Delta Electronics distributor. Authorized returns must be shipped prepaid. Repaired or replacement products wll be shipped by Delta Electronics F.O.B. shipping point.
  3. Delta Electronics shall not be liable for any indirect, incidental, consequential, punitive, or special damages arising out of or in connection with products use or performance, regardless of the form of action whether in contract, tort (including negligence), strict product liability or otherwise.
  4. This warranty does not extend to fluorescent lamp starters and tubes.
  5. The warranty does not cover if user does not comply with the manufacturer’s installation manual.
  6. To qualify for warranty service, you must notify Delta Electronics at the address or telephone number below.
  7. Delta Electronics shall have no liability to the original owner-user with respect to any defect caused by abuse,misuse, neglect, improper transportation or storage, improper testing, improper installation, improper operation, improper use, improper maintenance, improper repair, improper alteration, improper modification, tampering or accident of products or parts thereof, or unusual deterioration or degradation of products or parts thereof due to
    a physical environment beyond the requirements of products’ specifications.

Address: 46101 Fremont Boulevard, Fremont, CA 94538
US Toll Free Number: 1-888-979-9889
www.deltabreez.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals