Gude GGH 30 R Gas Heater Instruction Manual
- June 3, 2024
- Gude
Table of Contents
Translation of the original instructions
Gas heater GGH 30 R Gas Heater
Instruction Manual
GGH 30 R Gas Heater
Please read the instructions carefully before starting the machine.
**** This appliance is designed for use in Germany and Austria (700mbar).
Technical Data
Art. No | 85160 |
---|---|
Device category | I3B/P (700) |
Supply voltage | 220 – 240 V ~ |
Frequency | 50 Hz |
Heat output | 18 – 30 kW |
15.477 – 25.795 kcal/h
Gas consumption| 1.300 – 2.180 g/h
Length of connection cable| 130 cm
Power input max./Fan| 0,32 A
Power consumption max./Fan| 70 W
Fan power| 1.000 m³/h
Protection type| IPX4
Connection hose| 150 cm
Hose type| class 2 | 6,3 mm | 10 bar
Type of gas| Propane (G31), Butane(G30) or mixtures thereof
Size of gas cylinder| 5 kg | 11 kg
Operating pressure P| 700 mbar
Over-temperature protection| 110 ° C
Classification of the device according to air output temperature| 76 K | Type
A3
Device class| Space heater
Air output temperature (1,5 m Distance)| 76 ° C
Destination countries| DE + AT
Dimensions L x W x H| 460 x 240 x 400 mm
Net/gross weight| 6,1 / 7,3 kg
Heat output
Heat output | Pnom | 30 kW |
---|---|---|
Minimum heat output (inactive) | Pmin | 18 kW |
max. Continuous heat output | Pmax | 30 kW |
Fuel
Select fuel | gaseous | G30 |
---|---|---|
Minimum heat output (indicative) | NOx | 120,41 [mg/kWhinput] (GCV) |
Additional power consumption
At rated output | elmax | – kW |
---|---|---|
At minimum output | elmin | – kW |
At minimum output | elSB | – kW |
Power requirement of pilot flame
Power requirement of pilot flame(if present) | Ppilot | 0 kW |
---|
Thermal efficiency (NCV)
At rated heat output | ηth, nom | 100% |
---|---|---|
At minimum heat output (Reference value) | ηth, min | 100% |
Type of heat output/room temperature control (select one)
Single-stage heat output without room temperature control | – |
---|---|
Two or more manual stages without room temperature control | x |
With room temperature control using mechanical thermostat | – |
With electronic room temperature control | – |
Electronic room temperature control with daily timer | – |
Electronic room temperature control with weekly timer | – |
Other control options (multiple selection possible)
Room temperature control using presence detection | – |
---|---|
Room temperature control using open window detection | – |
With remote control option | – |
With adaptive switch-on control | – |
With operating time limit | – |
With “Black Bulb” temperature sensor, black | – |
Space heating annual efficiency | ηs: 91 % |
Energy Efficiency Index | – |
Energy Efficiency Class | A |
(*)NOX= Nitric oxides
**** Read and understand the operating instructions before using the appliance. In case of any doubts about connection and operation refer please to our customer center
The product is designed for use by persons aged 16 or older. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
Specified Conditions of Use
This product is only suitable for occasional use. The gas fan heater is
designed for heating, drying buildings and de-icing and must only be operated
in well-ventilated rooms or outdoors. Ventilation openings of at least 750 cm
2 must be avail- able in the room where the appliance is installed (at least
25 cm 2 per 1 kW rated heat output). The minimum room size must not be less
than 300 m 3 (1 m 3 per 100 W rated heat output). When using the device, the
respective local building and fire protection regulations must be observed.
Please note that our equipment has not been designed for commercial, craft or
industrial use. If the equipment is used in commercial, craft or industrial
operation or for similar activities, we cannot assume any liability. Do not
use this product in any other way as stated for normal use. Not observing
general regulations in force and instructions from this manual does not make
the manufacturer liable for damages.
The gas heater must not be used::
IT MUST NOT BE USED FOR HEATING HABITABLE ROOMS IN RESIDENTIAL BUILDINGS;
FOR USE IN PUBLIC BUILDINGS, OBSERVE NATIONAL REGULATIONS.
The device must not be operated in environments or 0rooms below ground level.
Do not install the device in rooms at risk of explosions and fire.
In the vicinity of combustible materials (e.g. paper, building materials);
An explosive atmosphere may be created in places wherevolatile materials (e.g.
gasoline, solvents, chemicals) are stored or present;
The apparatus is not intended for drying of clothing or for installation under
benches or in floor trenches.
Do not use the device in animal husbandry or animal breeding.
After an arbitrary structural change in the gas heater; Theheater may not be
operated without a fire protection grille in its designated location. Only
operate the device when it is fully assembled!
In case of wrong, unauthorised connection to a gas source;
In places that are not sufficiently ventilated;
As a source of heat for events and festivals.
Emergency procedure
Conduct a first-aid procedure adequate to the injury and summon qualified
medical attendance as quickly as possible. Protect the injured person from
further harm and calm them down. If you seek help, state the following If you
seek help, state the following pieces of information: pieces of information:
- Accident site 2. Accident type 3. Number of injured persons 4. Injury type(s)
Safety instructions for Gas fan heater
Read all safety warnings and all instructions.
Failure to follow the warnings and instructions may result in electric shock,
fire and/or serious injury.
Save all warnings and instructions for future reference.
Some regions have regulations that restrict the use of the machine. Check with
your local authority for advice.
Warning – certain parts of the product may get hot enough to cause burns.
Particular caution is called for if children and persons requiring protection
are present.
Only use the device in a well-ventilated environment and away from combustible
materials.
Do not use or store explosive or flammable materials (e.g. fuel, paper,
paints) in the vicinity of the product.
Keep the following safety distances:
Air intake side 2,5 m; Air outlet side 3,5 m;
side 2,0 m; top 2,0 m; back 2,5 m.
Do not put foreign objects in the device.
Make sure that the fan is operating properly before igniting the burner.
Never place the gas cylinder in front of the gas fan heater when it is in use!
This is a fire hazard!
It must always be ensured that air can be taken in and ventedfreely.
The devices may not be used in atmospheres that contain oil, sulphur orsalt.
Do not set up in rooms at risk of fire (e.g. wood sheds).
Warning! – To prevent overheating, never cover the heater with anything.
Do not use this heater with a program switch, a time switch, a separate remote
control system or any other device that automatically switches the heater on,
as there is a risk of fire if the heater is covered or set up incorrectly.
Always switch off the device, as described in this manual, if you cannot leave
it in a safe state. Secure the device against unauthorised use, e.g. by
enclosing the gas cylinders. Leave the premises, move to a clear place and
warn other people.
Warning! – Danger of short circuit!
Never operate/touch the device with wet hands.
Protect the electrical parts from moisture. To prevent electrical shock, never
submerse these parts in water or other fluids during cleaning or when in
operation. Never hold the apparatus under flowing water.
Switch off the device and disconnect it from the power supply before replacing
accessory parts, cleaning work and if it is not in use.
Operation is only allowed with a safety switch against stray current (RCD max.
stray current of 30mA).
Warning! – Damaged mains cords pose a hazard of electrocution.
Handle the cord carefully. Hold the plug when unplugging the tool. Never use
the cord to carry the apparatus. Keep cord away from heat, oil, sharp edges or
moving parts. Replace damaged cords immediately. Damaged cords increase the
risk of electric shock and may create a fire. If the replacement of the supply
cord is necessary, this has to be done by the manufacturer or his agent in
order to avoid a safety hazard. Use extension cables with a maximum length of
5 meters and with a cable cross-section of not less than 1.5 mm 2 .
Use of extension cables of different length and crosssection and also of
adapters and multiple sockets should be avoided.
Warning! – Risk of asphyxiation and explosion if leaks occur.
The device must be disconnected from the gas cylinder after every use using
the gas cylinder shut-off valve!
Prevent any torsion stresses on the connection hose.
Make sure that the gas hose is not twisted.
People are prohibited from being in the installation area at any time.
Do not move the device when it is in use.
Always place the unit on a firm and flat surface!
Close the gas bottle valve after use.
Symbols
| To reduce the risk of injury, user must read instruction manual
---|---
| Caution / Caution!
| Before doing any work on the device pull the plug out of the socket.
| Do not tug at the cable to unplug the apparatus.
| European Conformity Mark
| Warning against hot surfaces!
Danger of burns!
| Covering the device poses a fire hazard!
| Keep distance of persons Observe to keep out of dangerous zone
****| Warning! Danger: high voltage
| Warning about inflammable substances
| Keep dry at all times. Never expose tool to rain.
| Do not use the device indoors
| Open flames are prohibited
| Keep the machine out of reach of children.
| Protect against frost.
| Energy Efficiency Class A
| Operating pressure P
| Gas valve
| Fan
| Piezo ignition
| Connect the pressure regulator to the gas cylinder valve and attach the gas
hose to the pressure regulator.
| Put the mains cable into a suitable socket.
| Open the gas cylinder valve.
| Switch on the device with the toggle switch and check from the intake side
whether the fan is rotating.
| Keep the gas valve knob pressed for approx. 10 seconds until the thermal
fuse has warmed up and keeps the gas supply open.
Then ignite using the piezo button.
| Close the gas cylinder valve to switch off.
Then let the fan run for 1-2 minutes to blow out any non-combusted gas and
cool down the device.
| Switch off the device at the toggle switch and disconnect it from the gas
cylinder by unscrewing the pressure regulator from the gas cylinder valve.
Any damaged or disposed electric or electronic devices must be delivered to appropriate collection centres.
Operation
An unpleasant smell may be produced when the device is used for the first time
in some cases. This is however completely harmless and will disappear
completely over time.
Before each use, check the device and its connecting parts and accessories for
damage.
Power on:
- Connect the pressure regulator to the gas cylinder valve.
- Connect the gas hose to the pressure regulator.
- Connect the gas hose to the heater.
- Open the gas cylinder valve.
- Check screw caps with leak detection spray or soapy water for possible gas leakage. Tighten again if necessary.
- Put the mains cable into a suitable socket.
- Press the On/Off switch to switch on the device.
- From the intake side, check whether the fan is rotating.
- If the fan is turning, keep the gas valve button pressed and at the same time press the ignition button repeatedly until the burner ignites.
- Keep the gas valve knob pressed for approx. 10 seconds until the thermal fuse has warmed up and keeps the gas supply open.
- Check that the gas heater is running continuously.
- Use the control dial to adjust the heat output to the desired level.
Power off:
- To switch off the gas heater, always close the gas cylinder valve first.
- Run the fan for 1-2 minutes to blow out any noncombusted gas and to cool down the unit.
- Switch the device off with the On/Off switch.
- Pull out the mains plug to disconnect the device from the mains.
- Disconnect the device from the gas cylinder by unscrewing the pressure regulator from the gas cylinder valve.
- Carry out the maintenance and cleaning work described in the instructions. Please note the intervals mentioned. (once a month, every 50 operating hours, after each season)
- Store the device and the gas cylinders as described in the chapter on storage
Handling of gas bottles.
Make sure the gas bottles are used and stored in rooms with sufficient air
inlet and outlet.
A leaking gas bottle may reduce the share of oxygen in the inhaled air and
therefore represent a risk of suffocation.
Before using the device, always check that the pressure controller seal is
correctly fitted and working properly.
Before use, make sure the gas bottle contains gas designed for the work being
done.
Gas bottles must always be safely fixed in a vertical position on a wall
support or on a specially manufactured gas bottle cart.
The liquid gas cylinder must be changed in a well-ventilated room or outdoors,
and away from open flames (cigarettes, candles or other devices with open
flames).
A gas cylinder with a pressure regulator attached must not be moved. Close the
gas bottle valve after use.
The gas bottle valve must be closed during transport.
Smell of gas or suspect leakage
If you smell gas or suspect a leak, do not use the device. If the device is in
use, the gas supply must be shut off immediately. Immediately open windows and
doors. Do not press any electrical switches (e.g. light switches), do not use
a telephone or similar and do not use any naked flames or sources of ignition!
The device must be checked and any faults remedied before it can be used
again.
Emergency procedure
- Stop the gas supply to the device.
- Move out of the danger zone immediately and make sure that no other persons are in the danger zone.
- Call the fire brigade.
Maintenance
Before doing any work on the device pull the plug out of the socket.
Do not tug at the cable to unplug the apparatus.
All activities that require the device to be opened may only be carried out by
Güde or authorised specialist companies.
Have the device checked annually or after a longer period of storage by a
specialist electrical company to ensure that it is in good working order.
Check the gas hose lines at least once a month as well as every time the gas
cylinder is replaced. If there are any signs of damage, the hose lines must be
replaced.
The entire device must be checked for correct functio nality, including a leak
test, once a month. A leak test can be carried out with a leak detection spray
or soapy water, for example.
Warning! – Never carry out a leakage check with an open flame.
Clean the fan blades and the inside of the heater with compressed air every
season or as needed.
Always keep children and unauthorised persons out of reach of the appliance.
Repairs and works specified in these instructions may only be performed by
qualified authorised staff.
Use only original accessories and original spare parts.
Keep the device, in particular the air vents, clean at all times. Never spray
water on the device body!
Do not clean the plastics with solvents, flammable or toxic fluids. For
cleaning, use a damp cloth only.
Only a regularly maintained and treated appliance can serve as a satisfactory
aid. Insufficient maintenance and care can lead to unforeseen accidents and
injuries.
Storage
When not in use and in storage
- Close the gas cylinder valve.
- Turn off the device and disconnect it from power supply. (» Power off )
- Unscrew the pressure regulator from the gas cylinder.
- Remove the gas cylinder from the device.
- Leave the device to cool after use.
Store the device and its accessories in a dark, dry and frost free place,
which cannot be accessed by children.
The optimum storage temperature is between 5 and 30°.
Always store the device and the gas cylinder separately.
Never store the liquid gas cylinder in environments or rooms below ground
level!
Never store liquid gas cylinders in unventilated places!
The gas cylinders must be fitted with valve protection caps and lock nuts when
stored.
Gas cylinders must always be stored upright! This also applies to empty gas
cylinders!
Warranty
Warranty period of 12 months applies to commercial use and 24 months applies
to private use and commences on the day of purchase of the device. The
guarantee solely covers inadequacies caused by material defect or
manufacturing defect. Original payment voucher with the sales date needs to be
submitted for any claim in the guarantee period. The guarantee does not cover
any unauthorised use such as appliance overloading, use of violence, damage as
a result of any unauthorised interference or caused by foreign items. Failing
to follow the operating and assembly instructions and common wear are also not
included in the guarantee.
Important information for the customer
Please note that returns within or outside the warranty period should always
be in the original packaging. This measure effectively avoids unnecessary
transport damage and any associated disputed ruling. Your equipment is
optimally protected only in the original box, and keeping it in that box will
ensure smooth processing.
Service
Do you have any technical questions? Any claim? Do you need any spare parts or operating instructions? We will quickly help you and without needles bureaucracy at our web pages at www.guede.com in the Servicing part. Please help us be able to help you. In order to identify your device in case of claim we need the serial No., product No. and year of production. All this data can be found on the type label.
Tel.: +49 (0) 79 04 / 700-360
Fax: +49 (0) 79 04 / 700-51999
E-Mail: support@ts.guede.com
Disposal
Do not dispose of electrical appliances in household waste; use the local
collection points. Ask your local authority where the collection points are to
be found. If electrical equipment is disposed of in an uncontrolled manner,
weathering can lead to dangerous substances entering the groundwater and from
there the food chain, or the flora and fauna can be poisoned for years. If you
replace the device with a new one, the seller is legally obliged at the least
to take back the old one to be disposed of free of charge.
Transport packaging disposal
The packaging protects the machine against damage during transport. Packaging
materials are usually chosen based on environment aspects and waste treatment
principles and are therefore recyclable. Returning the packaging into
material circulation saves raw materials and reduces waste production. Parts
of packagings (e.g. foils, styropor®) can be dangerous for children.
Risk of suffocation!
Keep parts of the packagings out of reach of children and dispose them as soon
as possible.
Failure removal
Error | Causes | Remedy |
---|---|---|
Gas odour | Gas hose or leaking connection. | Stop the gas supply to the device. |
Move out of the danger zone immediately and make sure that no other persons
are in the danger zone.
Call the fire brigade.
The motor does not start| No electricity| Check the cable, connect it to the
power supply and if necessary replace it or have it repaired by an expert.
Piezo-ignition does not ignite| Electrode in incorrect position| Call
specialist
No gas| Gas cylinder empty| Replace gas cylinder
Closed valve on the gas cylinder| Open valve
Burner ignites, flame goes off as soon as the gas valve is turned on| Thermal
element not yet hot properly| Try again
Safty thermostat turned off| Let the device cool down and then retry.
Burner flame goes off during operation| Excessive gas output| Have the
reduction valve checked or replaced
Gas cylinder empty| Replace gas cylinder
Insufficient gas input| Check and clean motor grid
Check fan
Wind or air draught extinguishes flame| Place the device outside wind or air
draught, let it cool down for several minutes and then retry.
Translation of the EC-Declaration of Conformity
We, hereby declare the conception and construction of the below mentioned
appliances correspond – at the type of construction beinglaunched – to
appropriate basic safety and hygienic requirements of EC Directives.
In case of any change to the appliance not discussed with us the Declaration
expires.
Gas heater,
85160 GGH 30 R
Appropriate EU Directives
2014/35 EU
1935/2004/EC
2011/65/EU&2015/863EU
2016/425/EU (PPE)
2015/1188/EU
2006/42 EC| 2014/30/EU
1907/2006/EC
2016/426/EU
2019/1784/EU
2014/29/EU
---|---
nnex IV
Name:……………….
No:………………….
Notified Body……………
Adress:…………………..
Type Ex. Cert.-No.:
97/68/EC_&2016/1628/EU
Emission No.:
2000/14/EC_2005/88/EC
Method of compliance assessment
Harmonised standards used
EN 1596:1998/A1:2004
EN 60335-1:2012+A11+A13+A1+A14+A2
EN 60335-2-102:2016
EN 62233:2008; EN 62321
EN 55014-1:2017+A11
EN 55014-2:2015
EN IEC 61000-3-2:2019
EN 61000-3-3:2013+A1
Guaranteed sound power level
Measured sound power level
Wolpertshausen, 10.05.2022
Managing Director
Authorized to compile the technical file
GÜDE GmbH & Co. KG
Birkichstrasse 6
74549 Wolpertshausen
Deutschland
Tel.: +49-(0)7904/700-0
Fax.: +49-(0)7904/700-250
eMail: info@guede.com