Please read the instructions carefully before starting the machine.
DELIVERED ITEMS
Assembly
Oil level inspection
Check the oil level whenever the appliance is to be put into operation. Add engine oil if necessary. Check the oil level whenever the appliance is to be put into operation. Add engine oil if necessary.
To ensure quality, every piece of equipment is subject to a test operation and
filled with motor oil. Oil is drained before transport; however, there can be
some motor oil remains on the dip stick. Please check carefully the oil level
and add motor oil again.
Fuel tank filling
Rubber mat
Working instructions
Operation – START
Operation – STOP
V-belt tensioning
Spark plug
Oil change
Air filter
Paper filter
to be cleaned with compressed air only!
Never use water!
Technical Data
Vibrating plate | GRP 160 |
---|---|
Art. No | 55539 |
Engine type | 4-stroke motor |
Rated power | 6,5 kW / 9 PS |
Contents | 270 cm3 |
tank capacity | Unleaded petrol |
Engine oil 10W-40 | 0,95 l |
Eccentric oil 15W-40 | 0,4 l |
Vibrations per minute | 4500 / min |
Moving speed | 22 m / min |
compacting pressuremax. | 30,5 kN |
Work plate | 700 x 500 mm |
Overall dimensions LxWxH in mm: App. 270x295x200 | 1170 x 440 x 830 mm |
Weight | 87 kg |
Noise details
Sound pressure level LPA1)| 94,3 dB (A)
Measured sound power level LWA1)| 102 dB (A)
Guaranteed sound power level LWA1)| 105 dB (A)
Measured according to EN ISO 3744, 2000/14/EG+ 2005/88/EG;
Uncertainty K = 2,5 dB (A)
Wear ear protectors!
Vibration details
Vibration total values (triaxial vector sum) determined according to EN 500:
Vibration emission value ah| 18 m/s²
Uncertainty K = 1,5 m/s2|
WARNING: The vibration emission level will vary because of the ways in
which a power tool can be used and may increase above the level given in this
information sheet.
The vibration emission level may be used to compare one tool with another.
It may be used for a preliminary assessment of exposure.
An accurate estimate of the vibratory load should also take into account the
times when the tool is shut down or when it is running but not actually in
use. This may significantly reduce the vibratory load over the total working
period.
Identify additional safety measures to protect the operator from the effects
of vibration such as: maintain the tool and the accessories, keep the hands
warm, organization of work patterns.
Read and understand the operating instructions before using the appliance.
Familiarize with the control elements and how to use the appliance properly.
Abide by all the safety measures stated in the service manual. Act responsibly
toward third parties.
The operator is responsible for accidents or risks to third parties.
In case of any doubts about connection and operation refer please to our
customer center
Persons over 18 years of age can only work on the appliance. An exception
includes youngsters trained in order to reach knowledge under supervision of
the trainer during occupational education.
This appliance has not been designed to be used by persons (including
children) with reduced physical, sensory or mental capabilities or with a lack
of knowledge or experience.
Children must be supervised in order not to play with the machine.
Specified Conditions Of Use
The vibrating plate is exclusively intended to be used for compressing small
to medium areas, foundations, terraces, pavements and driveways made of the
following materials:
sand, shingle, gravel, crushed stone, asphalt, low cohesive mixing materials
The following materials require the use of a rubber mat: paving stones, bricks
The machine is intended only for use on construction sites where on-site
conditions are conducive to the use of machinery.
Always place the unit on a firm and flat surface! Please ensure that the
machine does not tip over, slide or fall during use.
Please maintain enough distance from the secured edges of the construction pit
as well as any embankments.
The machine must never be used on a slope.
Do not work with the unit in an environment with a risk of explosion where
there are flammable liquids, gases or dust.
The machine must never be used in deep pits, tunnels or caves (> 1.5 m).
The work site must be free of electric cables as well as gas and water lines
that could sustain damage from the vibrations.
Not observing general regulations in force and instructions from this manual
does not make the manufacturer liable for damages.
The machine may only be used in a technically perfect condition and taking
into account all safety information.
The use of the machine is at the discretion of the operator; use at your
own risk.
Residual risks
Even when the device is used properly and all safety regulations are
complied with, there still may be some residual risks.
Risk of fire!
Never operate the unit near highly flammable materials.
Fuel is highly flammable.
Keep the fuel in suitable containers only.
The appliance may only be refueled outdoors and not near open fire or burning
cigarettes.
Refuel the engine only when switched off. Refuel before starting the
appliance. If the engine is running or still hot, it must not be refueled or
the tank cover opened.
After use, let the unit cool down for at least 10 minutes before refueling.
Make sure the fuel does not overflow. If the fuel overflows, the engine must
not be started. Remove any dirt from the appliance and prevent any attempt at
ignition until fuel fumes have evaporated.
Replace all fuel tank and container caps securely.
Fuel tank to be emptied outdoors only.
Risk of poisoning!
Exhaust gases, fuel and lubricants are toxic. Inhaling exhaust gases may be
fatal!
Do not operate the unit in closed spaces where dangerous carbon monoxide gases
may accumulate.
Risk of explosion!!
Petrol and petrol vapors are highly flammable, explosive.
Do not work with the unit in an environment with a risk of explosion where
there are flammable liquids, gases or dust.
Refuel the engine only when switched off.
Do not store any fuel near the unit.
Never keep the unit with petrol in the tank inside a building where petrol
vapors could get in contact with open fire or sparks.
Hearing damage
A longer stay in the immediate vicinity of the running unit may cause hearing
damage. Wear ear protectors!
Risk of crushing
Keep hands and feet away from moving parts. Wear safety shoes with steel
reinforcement!
Damage to health arising from vibrations to hand and arms if the device is
used for a long time or if the device is not guided and evaluated properly.
Vibration damping systems are no guaranteed protection against white finger
disease or carpal tunnel syndrome. Therefore, it is necessary to carefully
check the state of your fingers and wrist if you have regularly used the
appliance for a long time. If any symptom of the diseases above appears, seek
medical advice immediately. To reduce the white finger disease risk, keep your
hands warm and take regular breaks during your work.
Danger of burns !
Some parts of the appliance get too hot when the appliance is operated. Do not
touch any hot parts, e.g. engine and muffler. Contacting hot parts of the unit
may cause burns. Pay attention to the warnings on the advice.
Emergency procedure
Conduct a first-aid procedure adequate to the injury and summon qualified
medical attendance as quickly as possible. Protect the injured person from
further harm and calm them down. If you seek help, state the following pieces
of information: 1. Accident site, 2. Accident type, 3. Number of injured
persons, 4. Injury type(s)
Safety instructions
WARNING
Read all safety warnings and all instructions. Failure to follow the
warnings and instructions may result in electric shock, fire and/or serious
injury. Save all warnings and instructions for future reference.
Keep children and bystanders away while operating a power tool. Minimum safe
distance is 5 m.
Keep bystanders a safe distance away from work area. Anyone entering the work
area must wear personal protective equipment.
Protective equipment such as dust mask, non-skid safety shoes, hard hat, or
hearing protection used for appropriate conditions will reduce personal
injuries.
Check carefully the terrain where the appliance is being used and remove any
items that could get caught and be thrown away.
Poor lighting/light conditions represent a high safety risk. Provide adequate
lighting or good lighting conditions when working with the machine.
Before work can begin, operators must familiarize themselves with the work
site. Elements of the work site include, for example, obstacles around the
site or in the surrounding traffic, the load bearing capacity of the earth and
ensuring the construction site is safe and secured.
Safe operation requires sufficient operator knowledge of the functions and
positions of the controls and indicators or meters. Pay attention to the
illustrated pages in the front section of the manual.
The appliance should only be used when in a perfect state. Carry out a visual
inspection before switching the appliance on. Check especially the safety
equipment, electrical control elements, power lines and screw couplings for
any damage and if they are tightened appropriately. Replace any damaged parts
before the appliance is put into operation if necessary.
The appliance must not be used if damaged or safety equipment is defective.
Replace any worn-out and damaged parts.
It is strictly prohibited to disassemble, modify and purposely remove the
protective equipment on the unit and fit other protective equipment instead.
No change can be made in respect of engine and unit setting.
When working with this machine, do not use spare parts other than those
recommended by us. Using spare parts not recommend by us can result in serious
injuries to persons or damage to the machine. Oil products must not come into
contact with skin, eyes and clothing.
Transport and storage
- Secure the device against shifting and toppling during transport.
- Take care to prevent from fuel and oil leakage during transport.
- Handling equipment to be used only when handling the machine.
- The load bearing capacity of the earth must be high enough to carry the weight of the machine.
- It is prohibited to stand or work under suspended loads.
- Do not store the appliance in enclosed places just after being switched off but let it cool down outdoors instead.
- Machine to be stored in a dry place. When the appliance is not going to be used for a long time, store it with an empty tank.
Symbols
| Caution!
---|---
| Warning against hot surfaces!
Danger of burns !
| Warning against dangerous electric voltage
| Warning about inflammable substances
| Observe to keep out of dangerous zone Minimum safe distance is 5 m.
| Read the operating instructions to reduce the risk of injury.
| Wear ear protectors!
Wear eye protective goggles !
| Wear gloves!
| Wear safety shoes with steel reinforcement!
| Slow
| Quickly
| Switch off the engine before any work on it.
| Prohibited
smoking and open fire using.
| Warning against risk of tripping
| Warning against thrown-off items
| Risk of poisoning!
Use the appliance only outside, never use it in confined and bad ventilated
areas.
| Risk of crushing
| Handling equipment to be used only when handling the machine.
| Any damaged or disposed electric or electronic devices must be delivered to
appropriate collection centers.
Dispose of old oil in an environmentally friendly manner.
Make sure the oil products do not enter the soil.
****| CE marking
| Guaranteed sound power level LWA
---|---
| Unleaded petrol
Maintenance
Switch the engine off and remove the socket plug before any work on the
engine. Wait until the unit has cooled down.
Keep the device, in particular the air vents, clean at all times. Never spray
water on the device body!
Do not clean the plastics with solvents, flammable or toxic fluids. For
cleaning, use a damp cloth only. Repairs and works specified in these
Instructions may only be performed by qualified authorized staff.
Use only original accessories and original spare parts. Carry out a visual
inspection before switching the appliance on.
Check especially the safety equipment, electrical control elements, power
lines and screw couplings for any damage and if they are tightened
appropriately.
Only a regularly maintained and treated appliance can serve as a satisfactory
aid. Insufficient maintenance and care can lead to unforeseen accidents and
injuries.
If necessary, a list of spare parts can be found at
www.guede.com.
Guarantee
Warranty period of 12 months applies to commercial use and 24 months applies
to private use and commences on the day of purchase of the device.
The guarantee solely covers inadequacies caused by material defect or
manufacturing defect. Original payment voucher with the sales date needs to be
submitted for any claim in the guarantee period.
The guarantee does not cover any unauthorized use such as appliance
overloading, use of violence, damage as a result of any unauthorized
interference or caused by foreign items. Failing to follow the operating and
assembly instructions and common wear are also not included in the guarantee.
Important information for the customer
Please be sure to know that returning the product in or after the warranty
period must be made in the original packaging.
Service
Do you have any technical questions? Any claim? Do you need any spare parts or
operating instructions?
We will quickly help you and without needles bureaucracy at our web pages at
www.guede.com in the Servicing part. Please help us be able to help you. In
order to identify your device in case of claim we need the serial No., product
No. and year of production. All this data can be found on the type label.
Tel.: +49 (0) 79 04 / 700-360
Fax: +49 (0) 79 04 / 700-51999
E-Mail: support@ts.guede.com
Inspection and maintenance plan
Repairs and works specified in these Instructions may only be performed by qualified authorized staff. Use only original accessories and original spare parts.
Regular servicing period| Before any start-up| After 1 month or
20 hours of operation| After 3 months or
50 hours of operation| After 6 months or
100 hours of operation| After 200 hours of
operation
---|---|---|---|---|---
Engine oil| Inspection| | | | |
Change| | | | |
Eccentric oil| Change| | | | |
Petrol hose Exhaust system Choke Cable starter| Inspection| | | | |
Air filter| Clean| | | | |
Change| | | | |
Petrol filter| Clean| | | | |
Spark plug| Inspection Clean| | | | |
Tip: To ensure reliable operation of the appliance, we strongly recommend
using fuel additives and performing 2-3 test operations after a longer time of
not using the unit.
Failure removal
Failures | Causes | Removal |
---|---|---|
The motor does not start. | Closed fuel tap | Make sure the fuel tap and On/Off |
are in
the „ON“ position
Lack of fuel| Add some fuel
Weak tension on the starter| Pull strongly the starting cord.
Wrong fuel, storing without petrol tank being drained| Drain the fuel tank and
carburetor, add fresh petrol
Scooted spark plug (carbon residues on electrodes), electrodes distance too
big| Clean the spark plug, check the plug thermal value, possibly change the
plug, set the electrodes distance to 0.6-0.7 mm
The spark plug is wet from petrol (oversaturated engine).| Dry the spark plug
out and refit it.
Little oil in the engine| Add oil
Unit is not in a horizontal position. Lack
of oil being signaled| Place the unit in a horizontal position
Choke has not been used| Use the choke
Engine running irregularly| Problem with ignition| Make sure the spark plug is
fitted properly. Make sure the spark plug cable is on the spark plug. Clean
the spark plug
and check the electrodes if correct.
Wrong fuel (propellant)| Make sure proper fuel has been used.
Translation of the EC-Declaration of Conformity
We, hereby declare the conception and construction of the below mentioned
appliances correspond – at the type of construction being launched – to
appropriate basic safety and hygienic requirements of EC Directives.
In case of any change to the appliance not discussed with us the Declaration
expires.
Vibrating plate
55539 GRP 160
Appropriate EU Directives
2014/35/EU
1935/2004/EC
2011/65/EU ROHS
2006/42/EC
Annex IV
Name:
Address:
No:
Type Ex. Cert.-No.:| 2014/30/EU
1907/2006/EC
2009/142/EC
2009/105/EG (…<20.04.2016)
2014/29/EU (…>20.04.2016)
---|---
97/68/EC_
2010/26/EU
Emission No.:
2000/14/EC_2005/88/EC
Method of compliance assessment
Annex V
**** Wolpertshausen,
08/09/2017
Harmonized standards used
Helmut Arnold
Managing Director
Gide GmbH & Co. KG,
Birkichstraße 6,
74549 Wolpertshausen, Germany
EN 500-1:2006/A1:2009
EN 500-4:2011
EN 55012:2007/A1:2009
EN 61000-6-1:2007
Guaranteed sound power level: LWA 105 dB (A)
Measured sound power level: LWA 102 dB (A)
Authorized to compile the technical file
GÜDE GmbH & Co. KG
Birkichstrasse 6
74549 Wolpertshausen
Deutschland
Tel.: +49-(0)7904/700-0
Fax.: +49-(0)7904/700-250
E-Mail: info@guede.com
TN 55539
2017-10
References
- Güde | Maschinen & Werkzeuge für den Hand- & Heimwerker
- Güde | Maschinen & Werkzeuge für den Hand- & Heimwerker
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>