Gude 415 10 50 2200 W 10 bar 50 liters Compressor Instruction Manual

October 27, 2023
Gude

Translation of the original instructions

Gude 415 10 50 2200 W 10 bar 50 liters Compressor- fig
8

415 10 50 2200 W 10 bar 50 liters Compressor

Please read the instructions carefully before starting the machine.

DELIVERED ITEMS

Gude 415 10 50 2200 W 10 bar 50 liters Compressor- fig
8

Assembly

Gude 415 10 50 2200 W 10 bar 50 liters Compressor- fig
1| Gude 415 10 50 2200 W 10 bar 50 liters Compressor- fig
2
---|---

Starting-up the machine

Gude 415 10 50 2200 W 10 bar 50 liters Compressor- fig
3| Gude 415 10 50 2200 W 10 bar 50 liters Compressor-
fig5
---|---
Gude 415 10 50 2200 W 10 bar 50 liters Compressor- fig
4| Gude 415 10 50 2200 W 10 bar 50 liters Compressor- fig
6

Operation – START

Gude 415 10 50 2200 W 10 bar 50 liters Compressor-
fig7

Operation

Gude 415 10 50 2200 W 10 bar 50 liters Compressor- fig
8| Gude 415 10 50 2200 W 10 bar 50 liters Compressor- fig
9
---|---

Engine protection

Gude 415 10 50 2200 W 10 bar 50 liters Compressor-
fig10

Drain the condensate

After approx. 2-4 hours of use, the condensate that has formed must be drained from the receiver.

Gude 415 10 50 2200 W 10 bar 50 liters Compressor-
fig12

V-belt tensioning

Gude 415 10 50 2200 W 10 bar 50 liters Compressor-
fig13

V-belt replacement
Gude 415 10 50 2200 W 10 bar 50 liters Compressor-
fig14

Maintenance-Air filter

Gude 415 10 50 2200 W 10 bar 50 liters Compressor-
fig16

Check valve inspection

Gude 415 10 50 2200 W 10 bar 50 liters Compressor- fig
17

Technical Data

Compressor| 490/10/50 400V| 420/10/50 EU 230V| 580/10/50 EU 400V
---|---|---|---
Art. No| 50008| 50016| 50018
Service connection| 4000 V~50 Hz| 230 V~50 Hz| 400 V~50 Hz
Motor output S3/ 60%| 2,2 kw| 2,2 kw| 2,2 kw
Number of cylinders| 2| 2| 2
Suction capacity| 490 l/min| 320 l/min| 435 l/min
Free air delivery| 325 l/min| 250 l/min| 302 l/min
Max. working pressure| 10 bar| 10 bar| 10 bar
tank capacity| 50 l| 50 l| 50 l
weight| 62 kg| 48 kg| 59 kg
Degree of protection| IP 20| IP 54| IP 54
Protection class| 1| 1| 1
Sound power level LwA *| 96 db(A)| 96 db(A)| 96 db(A)

*Measured according to 2005/88/EC

Compressor 415/10/50 N 420/10/100 EU 230V 580/10/100 EU 400V
Art. No 50053 50071 50073
Service connection 4000 V~50 Hz 230 V~50 Hz 400 V~50 Hz
Motor output S3/ 60% 2,2 kw 2,2 kw 2,2 kw
Number of cylinders 2 2 2
Suction capacity 490 l/min 320 l/min 435 l/min
Free air delivery 325 l/min 250 l/min 302 l/min
Max. working pressure 10 bar 10 bar 10 bar
tank capacity 50 l 50 l 50 l
weight 62 kg 48 kg 59 kg
Degree of protection IP 20 IP 54 IP 54
Protection class 1 1 1
Sound power level LwA * 96 db(A) 96 db(A) 96 db(A)

*Measured according to 2005/88/EC
Read and understand the operating instructions before using the appliance. Abide by all the safety measures stated in the service manual. Act responsibly toward third parties.
In case of any doubts about connection and operation refer please to our customer center Preserve all the documentation so that anyone who uses the compressor can consult this beforehand.
Specified Conditions Of Use
The compressor may only be used to produce compressed air at home, on yards and in  workshops. –
The compressed air produced by the compressor cannot not be used for pharmaceutical, food or medical purposes or to fill the air bottles of scuba divers.
The compressor must be used in a suitable environment (well ventilated with an ambient temperature of between +5°C and +40°C) and never in places with dust, acids,  vapors, explosive or flammable gases.
Do not use this product in any other way as stated for normal use. Not observing general regulations in force and instructions from this manual does not make the manufacturer liable for damages.

Safety instructions

WARNING! Electric shock! There is a risk of an injury caused by electric shock!
Operation is only allowed with a safety switch against stray current (RCD max. stray current of 30mA).
Check the voltage. Technical data given on the type label must correspond with electric network voltage. Insert the plug of the electrical cable in a socket of suitable shape, voltage and frequency complying with current regulations.
Use extension cables with a maximum length of 5 meters and with a cable cross- section of not less than 1.5 mm2. Use of extension cables of different length and cross-section and also of adapters and multiple sockets should be avoided.
Check the cable and/or socket for damages before the appliance putting into operation.
To avoid danger, a damaged mains supply pipe must be replaced by the manufacturer. Do not under any circumstances attempt any repair yourself. Never let the compressor come into contact with water or other liquids and never direct the jet of liquids sprayed by tools connected to the compressor towards the compressor: as the appliance is live, this could cause electrocution or short-circuits. Never use the appliance with bare feet or wet hands or feet. Never yank the power cable to disconnect the plug from the power outlet or to move the compressor. warning: the compressor may restart when power is restored following a blackout.
Compressed air is a potentially dangerous form of energy; always take great care when using the compressor and its accessories.
This device is not intended for use by persons (including children) with limited physical, sensory or mental capabilities or without the necessary lack experience or knowledge unless they are supervised by a person who is responsible for their safety or were instructed by that person in how to use the device. Children should be supervised to ensure that they do not play with the device. Always keep children and unauthorised persons out of reach of the appliance. Never use the compressor without being supervised. Never direct the jet of air towards persons, animals or your body. Never keep the air flow in body holes as that could lead to fatal injuries! Keep the work area free. when operating, the compressor must be placed on a stable surface.
Caution! The compressor may only be used with appropriate wheels and rubber bumps. Safety goggles should be worn when using the compressor in order to protect the eyes against any foreign bodies lifted by the jet of air. If possible, when using air-powered accessories, wear safety clothing. Always maintain a safety distance of at least 4 meters between the compressor and the work area. Caution! The pneumatic hose may lash you when the quick-acting coupling is opened! The pneumatic hose should be held by hand. Always use the handle to move the compressor.
when using compressed air, you must know and comply with the safety precautions to be adopted for each type of application (inflation, airpowered tools, painting, washing with water-based detergents only, clinching, etc.).
when using compressed air, you must know and comply with the safety precautions to be adopted for each type of application (inflation, airpowered tools, painting, washing  with water-based detergents only, clinching, etc.).
Caution! Never switch the compressor on or off using the plug. Pressure switch to be pressed at all times. Do not leave the compressor on over night as it could become a source of danger.
At the end of your working day, switch the appliance off, release the air jet and unplug the compressor. warning: if the water that condenses is not drained, it may corrode the receiver, reducing its capacity and impairing safety.
Never leave the appliance exposed to adverse weather conditions (rain, sun, fog, snow).
If this compressor is used outdoors, always remember to stow it after use  in acovered or closed place.
Never use the compressor outdoors in rain or bad weather.
Do not place flammable or nylon/fabric objects close to and/or on the compressor.
Do not cover the air inlets on the compressor.
The compressor must not be fitted in a vehicle for industrial purposes without an inspection by an expert!
If the compressor is used for industrial purposes, it must be checked by an expert before putting into operation for the first time. Such check must be ordered by the operator (under betrSichV Section 17 No. 25 – operation safety regulation)
Caution! when fitted in automatic equipment, it is necessary to install appropriate alarm or warning devices in case of power outage or malfunction or compressor (e.g. feed line, etc.) failure.
Requirements for operating staff
To guarantee perfect and reliable operation of the rotary and percussive pneumatic tools such as impact wrenches, staplers or nailers, etc., the compressed air must be supplied filtered – with oil via the lubricator or maintenance unit A filtered water separator should be used for varnishing in any case.
To select a suitable pneumatic tool, the tool air consumption and the compressor effective amount delivered must necessarily be considered.
(Pneumatic tools and accessory equipment can be found at www.guede.com)
Operation at lower temperatures
At lower temperatures, below 5°C, problems may be experienced when starting. They are manifested by growling of the electric motor. In such a case, the appliance must be immediately switched off and oil (5w30) changed in warmer conditions.
Requirements for operating staff
The operating staff must carefully read the Operating Instructions before using the appliance. qualification:  Apart from the detailed instructions by a professional, no special qualification is necessary for appliance using. Minimum age:  Persons over 16 years of age can only work on the appliance. An exception includes youngsters trained in order to reach knowledge under supervision of the trainer during occupational education. Training:  Using the appliance only requires corresponding training by a professional or the Operating Instructions. No special training is necessary.
Emergency procedure
Conduct a first-aid procedure adequate to the injury and summon qualified medical attendance as quickly as possible. Protect the injured person from further harm and calm them down. For the sake of eventual accident, in accordance with DIN 13164, a workplace has to be fitted with a first-aid kit. It is essential to replace any used material in the first-aid kit immediately after it has been used. If you seek help, state the following pieces of information:

  1.  Accident site
  2. Accident type
  3. Number of injured persons
  4. Injury type(s)

Maintenance

Before carrying out any work on the machine, disconnect the plug from the socket.
Run the accessory connected dry until there is no more air in the receiver.
Prior to every use, visually check the machine to rule out any defects, in particular on the power cable and the plug.
Safety valve Functional check.
The machine must not be used under any circumstances if the machine  or the safety devices are damaged.
Use only original accessories and original spare parts.
Never clean the machine and its components with solvents, flammable or toxic liquids. Us only a damp cloth making.
Only a regularly maintained and treated appliance can serve as a satisfactory aid. Insufficient maintenance and care can  lead to unforeseen accidents andinjuries.
If necessary, a list of spare parts can be found at www.guede.com.

Guarantee

warranty period of 12 months applies to commercial use and 24 months applies to private use and commences on the day of purchase of the device. The guarantee solely covers inadequacies caused by material defect or manufacturing defect. Original payment voucher with the sales date needs to be submitted for any claim in the guarantee period. The guarantee does not cover any unauthorised use such as appliance overloading, use of violence, damage as a result of any unauthorised interference or caused by foreign items. Failing to follow the operating and assembly instructions and common wear are also not included in the guarantee.

Service

Do you have any technical questions? Any claim? Do you need any spare parts or operating instructions? we will quickly help you and without needles bureaucracy at our web pages at www.guede.com in the Servicing part. Please help us be able to help you. In order to identify your device in case of claim we need the serial No., product No. and year of production. All this data can be found on the type label. Please enter it here for future reference:

Serial No.:………
Art. No:……………
Year of production:…….

Symbols

| Read the Operating Instructions
---|---
| wear eye protective goggles ! wear ear protectors!
| Protect against humidity Never expose tool to rain.
| Cable pulling / transport prohibited
| warning/caution
| Dangerous voltage
****| Caution – hot surface!
Danger of burns !
| Danger – automatic control (closed loop)
| Any damaged or disposed electric or electronic devices must be delivered to appropriate collection centres.
| Protect against humidity
| This side up

Failure removal

Failures Causes Removal

Compressor not starting after being
switched on| Pressure in the air jet exceeds the closing pressure
Defective supply
Defective pressure switch
worn carbons| Release the pressure in the air jet so that the pressure switch gets automatically switched on
Have the current supply checked by an authorised person
Have the pressure switch replaced by an authorised person (Güde service centre)
Replace the carbons
After reaching the closed pressure, the compressor runs or buzzes for a short time and then switches off
automatically| Electric cable is too long or its cross
section is too small| Check the length and cross section of the electric cable
Compressor running constantly| Suction filter is very dirty
Pneumatic tools have high air consumption
Leaking on the compressor
Compressed-air pipeline leaking
Drain valve is open or missing| Clean or replace the suction filter
Check the pneumatic tool air consumption; seek an authorised compressed air dealer
Localise the leaking, contact the Güde service centre
Contact the Güde service centre
Close or insert the drain valve
Compressed air is released from the discharge valve under the pressure switch when the appliance is being operated| Discharge valve is leaking| Clean or replace the discharge valve
After reaching the cut-off pressure, air is released from the discharge valve under the pressure switch until the closing pressure is reached| Check valve insert is leaking or defective
Check valve is damaged| Clean or replace the check valve insert 16
Replace the check valve
Compressor gets started too often| Too much condensate in the air jet| Drain the condensate
Safety valve blowing off| Pressure in the air jet exceeds the set cut-off pressure
Safety valve is defective| Have the pressure switch adjusted/replaced by an
authorised person (Güde service centre)
Replace the safety valve or contact the Güde service centre
Compressor getting warm too much| Air supply is not sufficient
Cooling fins on the cylinder (cylinder head) are dirty
Too long time of appliance operation| Make sure sufficient air supply and outlet (minimum distance from wall is 40 cm) is provided
Clean the cooling fins on the cylinder (cylinder head)
Switch the compressor off
Compressor being overheated and keeps switching off| Compressor is overloaded
Compressor is defective
Compressor under undervoltage
Outdoor temperature of 35°C| Contact the Güde service centre
Contact the Güde service centre
Contact the Güde service centre

EC-Declaration of Conformity
we, hereby declare the conception and construction of the below mentioned appliances correspond – at the type of construction being launched – to appropriate basic safety and hygienic requirements of EC Directives. In case of any change to the appliance not discussed with us the Declaration expires.

Compressor

490/10/50 400V #50008 LwA 96 db(A) L WAm94,2db(A)
420/10/50 EU 230V #50016 LwA 96 db(A) L WAm94,2db(A)
580/10/50 EU 400V #50018 LwA 96 db(A) L WAm95,2db(A)
415/10/50 N #50053 LwA 97 db(A) L WAm94,2db(A)
420/10/100 EU 230V #50071 LwA 96 db(A) L WAm94,2db(A)
580/10/100 EU 400V #50073 LwA 97db(A) L WAm95,2db(A)

LwA Guaranteed sound power level
LwA measured sound power level
Appropriate EU Directives
2006/42 EG, 2004/108 EG, 2009/105/EG, 2000/14 EG Annex VI
Harmonised standards used
EN 1012:2010
EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 + A14:2010
EN 60204-1:2011
EN 55014-1:2006 + A1:2009
EN 55014-2:1997 + A1:2001 + A2:2008
EN 61000-3-2:2006 + A1:2009 + A2:2009
EN 61000-3-3:2008

Güde GmbH & Co. KG
Germany
GÜDE GmbH & Co. KG,
birkichstrasse 6, 74549 wolpertshausen,
Germany Managing Director
Technische Dokumentatio

GÜDE GmbH & Co. KG
birkichstrasse 6 74549 wolpertshausen
Deutschland
Tel.: +49-(0)7904/700-0
Fax.: +49-(0)7904/700-250
eMail: info@guede.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals