GE 72inches Industrial Pendant Fixture User Manual

June 3, 2024
GE

GE 72inches Industrial Pendant Fixture

PRODUCT COVERED

GE 72inches-Industrial-Pendant-Fixture-FIG-
15

BEFORE YOU BEGIN
Read these instructions completely and carefully.

WARNING

  • Risk of fire or electric shock. Installation requires knowledge of luminaire electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician.
  • These products are intended to be used in dry or damp locations.
  • MAX 60 watts incandescent.

PREPARE ELECTRICAL WIRING

Electrical Requirements

The LED fixture must be supplied with 120Vac 6GHz.

Grounding Instructions

The grounding and bonding of the overall system shall be done in accordance with
National Electric Code (NEC) and local codes.

TOOLS REQUIRED

GE 72inches-Industrial-Pendant-Fixture-FIG-
\(8\)

PACKAGE CONTENTS

Only 1 pcs fixture is included in the package. Please check the package list according to the fixtures you purchased.GE 72inches-Industrial-Pendant-
Fixture-FIG- \(9\)

Accessories for all models

GE 72inches-Industrial-Pendant-Fixture-FIG-
\(10\)

BEFORE INSTALLATION

  1. Unscrew the locking ring at the bottom.
  2. Install the decorative rings on the socket
  3. Screw the locking ring tightly.

INSTALLATION

This fixture is suitable for junction with 2.75inches or 3.5 inches mounting distance.

  1. Turn off power source to the power supply where you are installing the fixture
  2. Remove existing fixture and disconnect all electric wiresGE 72inches-Industrial-Pendant-Fixture-FIG- \(6\)
  3. Remove decorative nuts from crossbar. Save the decorative nuts for later use.
  4. Attach crossbar to the junction box with screws providedGE 72inches-Industrial-Pendant-Fixture-FIG- \(7\)
  5. Adjust crossbar: Temporarily place fixture over crossbar to determine amount of adjustment necessary for screws on crossbar. Screws should come through canopy hole to ensure decorative nuts can be used to tighten fixture to ceiling.
  6. Adjust the cord length: Loosen cord restrain on the fixture canopy. Adjust cord to desired length by pulling cord up through canopy then re-tighten cord restrain.GE 72inches-Industrial-Pendant-Fixture-FIG- \(11\)
  7. Cut excess wire if needed. Leave at least 10″ of extra wire to work with. Strip and prepare wires for connection
  8. Connect same color wires of outlet box and fixture together by wire nuts. Note that junction box ground wire may be green or bare copper.GE 72inches-Industrial-Pendant-Fixture-FIG- \(12\)
  9. Arrange excess wires and wire nuts within canopy. Align holes in canopy with screws on cross bar and push up. Secure fixture to cross bar by tightening the fixture with 2 decorative nuts.
  10. Install a medium base bulb.GE 72inches-Industrial-Pendant-Fixture-FIG- \(13\)
  11. Turn ON the power to the fixture.

Bulbs not included in package.