MEAN WELL LPC-100 Series 100W Single Output LED Power Supply Owner’s Manual
- June 3, 2024
- MEAN WELL
Table of Contents
MEAN WELL LPC-100 Series 100W Single Output LED Power Supply
Features
- Constant current design
- Universal AC input/full rauge
- Withstand 300VAC surge input for 5 seconds
- High efficiency up to 90%
- Protections: Short circuit/ Over voltage
- Cooling by free air convection
- Fully encapsulated with IP67 level (Note.6)
- Fully isolated plastic case
- Class II power unit, no FG
- 100% full load burn- in test
- Low cost, high reliability
- 2 years warranty (Note.4)
Description
LPC-100 series is one 1 00W single output AC/DC LED switching power supply. It features the constant current design, providing various models with the output current ranging from 350mA through 21 00mA the LED lighting applications employ the most frequently.
LPC-100 operates for the range 90~264VAC so it can perfectly work for most of the countries in the world. The whole series is based on class II (without FG pin) design, housed with a 94V-0 flame retardant plastic case. With the working efficiency up to 90%, LPC-100 can work at the ambient temperature between -25°C~+50°C under air convection.
Model Encoding
Applications
- Suitable for LED related fixture or appliance (such as LED Decoration or Advertisement devices)(Note.9)
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
SPECIFICATION
MODEL| LPC-100-350| LPC-100-500| LPC-100-700|
LPC-100-1050| LPC-100-1400| LPC-100-1750| LPC-100-2100
---|---|---|---|---|---|---|---
OUTPUT| RATED CURRENT| 350mA| 500mA| 700mA| 1050mA| 1400mA| 1750mA|
2100mA
CURRENT ACCURACY| ±5.0%
CONSTANT CURRENT REGION Note.5| 143 ~ 286V| 100 ~ 200V| 72~143V| 48 ~
96V| 36 ~ 72V| 29 ~ 58V| 24 ~ 48V
RATED POWER| 100.1W| 100W| 100.1W| 100.BW| 100.BW| 101.5W| 100.BW
RIPPLE CURRENT| ±5%
RIPPLE & NOISE| 1.5Vp-p| 1.5Vp-p| 1Vp-p| 1Vp-p| 1Vp-p| 1Vp-p| 1Vp-p
LINE REGULATION| ±1%
VOLTAGE TOLERANCE| ±1.5%
SETUP, RISE TIME| 1000ms, 80ms/ 230VAC 2000ms,80ms/115VAC at full
load
HOLD UP TIME (Typ.)| 16ms/230VAC 10ms/115vac at full load
INPUT| VOLTAGE RANGE Note.2| 90 – 264VAC 127VDC – 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
EFFICIENCY (Typ.)| 90%| 89.5%| 89%
AC CURRENT (Typ.)| 2.2A/ 115VAC 1.2A / 230VAC
INRUSH CURRENT (Typ.)| COLD START 75A(twidth=980µs measured at 50%
Ipeak) at 230VAC
MAX. No. of PSUs on 16A CIRCUIT BREAKER|
1 units (circuit breaker of type B) / 2 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT| <0.25mA I 240VAC
PROTECTION| SHORT CIRCUIT| Hiccup mode, recovers automatically
after fault condition is removed
OVER VOLTAGE| 315 – 345V| 220 ~ 240V| 160 – 172V| 108 ~ 120V| 80 – 97V|
65 ~ 80V| 58 – 68V
Protection type : Shut down and latch off o/p voltage re-power on to recovery
ENVIRONMENT| WORKING TEMP.| -25 – +50°C (Refer to “Derating Curve”)
WORKING HUMIDITY| 10 – 95% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +80°C, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/°C (0 ~ 50°C)
VIBRATION| 10 – 500Hz, 2G 10min./1cycle, period for 60min. each along X,
Y, Z axes
SAFETY & EMC| SAFETY STANDARDS| IEC 62368-1 ;EAC TP TC 004,
IP67, BS EN/EN62368-1 approved
WITHSTAND VOLTAGE| I/P-O/P 3KVAC
ISOLATION RESISTANCE| I/P-O/P:1DOM Ohms/ 500VDC / 25°C/ 70% RH
EMC EMISSION| Compliance to BS EN/EN55032(CISPR32) Class B; BS
EN/EN61000-3-2 Class A( ;cc 80% load); BS EN/EN61000-3-3, EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS
EN/EN55035, light industry level , EAC TP TC 020
OTHERS| MTBF| 4121.8K hrs min. Telcordia SR-332 (Bellcore) ;
511.2K hrs min.| MIL-HDBK-217F (25°C)|
DIMENSION| 1905237mm (LWH)
PACKING| 0.61Kg;20pcs/13.2Kg/0.55CUFT
NOTE|
- All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
- Derating may be needed under low input voltages. Please check the static characteristics for more details.
- The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
- Refer to warranty statement.
- Constant current operation region is within 50% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design.
- Suitable for indoor use or outdoor use without direct sunlight exposure, please avoid immerse in the water over 30minutes.
- The ambient temperature derating of 3.5°C/1000m with fanless models and of 5°C/1000m with fan models for operating altitude higher than 2000m(6500ft).
- For any application note and IP water proof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf
- This product is not intended for LED lighting luminaire applications in the EU.(ln the EU the LPF/NPF/XLG series are recommended.)
- Product Liability Disclaimer : For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
Mechanical Specification
Recommend Mounting Direction
Block Diagram
Derating Curve
Static Characteristics
Read User Manual Online (PDF format)