datacolor Formulation Software Match Textile Installation Guide

June 3, 2024
datacolor

Datacolor Monitor
Installation Guide

Installation Overview

This document describes the installation of Datacolor Software to your computer’s hard disk. If you have purchased your computer from us, the software will be already installed. If you purchased your own computer, follow these instructions to install our software on your computer.
Before you begin the installation, you should have all installation USB’s, and Microsoft Windows* should be properly installed on your computer.

1.1 System Requirements
The system requirements shown below are the minimum configuration to ensure effective operation of the standard Datacolor Monitor software. Configurations below stated requirements may work but are not supported by Datacolor.

Microprocessor Pentium IV 1.9 GHz processor require
RAM 512 MB minimum

1 GB is recommended, and for generally increased performance.
Hard Disk| Minimum of 2 GB free disk space.
Video Monitor/Graphics| 16 MB, high-resolution graphics card. Color patch displays require 1024 x 768 (small font) or better.
Printer| Windows supported printers: Ink Jet, Laser Printers. Dot matrix printers are not supported.
Mouse| Required.
Microsoft Windows| Windows 2000 Professional, WIN XP Pro, Windows 10
Network| Networks that are 100% windows compatible.
Datacolor MONITOR operates on networks compatible with the Microsoft Windows operating systems by using the application layer of the network operating system.

Before You Begin

  • Microsoft Windows® should be properly installed on your computer.
  • You must have Windows Administrator rights to install this software.
  • Restart the system before installing the software. This removes any memory-resident modules that may interfere with the installation, and is especially important if you have been running a previous version.
  • Install Sybase V12 database management software.
  • Close all other programs that are running.
  • Have all program installation readily available.

Important, Before You Begin! You must have Administrator Rights to install this software and you must have installed Sybase first!

Installation Procedure

To install Datacolor Monitor

  1. Place the Datacolor Monitor USB into the port.
  2. Select the Menu.exe

The Main Installation menu should appear automatically:

datacolor Formulation Software Match Textile - fig 1

Select Install Datacolor MONITOR

datacolor Formulation Software Match Textile - fig 2

When the Main Installation Menu is displayed, choose “Install Datacolor MONITOR” The Datacolor MONITOR installation will guide you through installing Datacolor MONITOR on your computer
Select a language from the list box.(Language include Chinese (simplified), Chinese (traditional), English, French (standard), German, Italian, Japanese, Portuguese (standard) and Spanish.) Local Area Network (LAN)

datacolor Formulation Software Match Textile - fig 3

Click “Next”. The installation wizard will start – follow the prompts to install Datacolor MONITOR on your computer.
The next dialogs only appear if pre Spectrum software is already installed on the system. If it’s a new installation the Setup proceeds with the Welcome dialog.
When you upgrade from CenterSideQC 1.x to Datacolor MONITOR v1.6, the Setup uninstalls the old software before the new Software is installed (DCIMatch; SmartSort; .CenterSiceQC,
Fibramix, matchExpress or Matchpoint)
The Setup asks you twice if you have made a backup of your databases. If not, click ‘No’ to exit the setup.

datacolor Formulation Software Match Textile - fig 4

Depending on the installed software you are informed about the un-installation process. The Setup program shows a message for each program that should be installed.
Uninstalling DCIMatch

datacolor Formulation Software Match Textile - fig 5

Uninstalling CenterSideQC (if installed)
datacolor Formulation Software Match Textile - fig 7◼ Uninstalling Fibramix (if installed)
datacolor Formulation Software Match Textile - fig 8Uninstalling SmartSort (if installed)
datacolor Formulation Software Match Textile - fig 9The setup continues with the Welcome dialog

datacolor Formulation Software Match Textile - fig 10

If you are installing Datacolor MONITOR for the first time, click “Next” to access the Datacolor Software
License Agreement dialog. You must select the acceptance radio button in order to install Datacolor MONITOR. If you are upgrading an existing, licensed copy of Datacolor Match, this screen will not appear.

datacolor Formulation Software Match Textile - fig 11

Select the acceptance radio button and click the “Next” button to proceed.

datacolor Formulation Software Match Textile - fig 12

datacolor Formulation Software Match Textile - fig 13

Click “Next” to select default installation folder. Normal default is C:\Program Files\Datacolor

Setup types

You will now see a screen offering you several different setup options.
Complete
(All modules are installed on your computer.)

datacolor Formulation Software Match Textile - fig 14

Select the Setup Type to install and click “Next”.
Custom:
Please note, this is not recommended for typical user installations.
Custom setup allows you to install specific features instead of the entire Datacolor MONITOR installation.

datacolor Formulation Software Match Textile - fig 15

Click “ Next ” to select the shortcuts to install .
At default, the installation will put Datacolor MONITOR icon on your desktop and a shortcut to start program menu.

datacolor Formulation Software Match Textile - fig 16

Click “ Next ” to continue the installation.

datacolor Formulation Software Match Textile - fig 17

Click “Install” to transfer the data Setup starts transferring the files

datacolor Formulation Software Match Textile - fig 18

datacolor Formulation Software Match Textile - fig 19

The ‘DataSecurityClient’ is installed
followed by installing the Datacolor Envision components:
datacolor Formulation Software Match Textile - fig 21followed by installing the instrument drivers:

datacolor Formulation Software Match Textile - fig 22

The database update starts if it is an update of a previous program version.

datacolor Formulation Software Match Textile - fig 23

Click the ‘Finish’ button at the end of the database update.
Followed by installing the Acrobat Reader

datacolor Formulation Software Match Textile - fig 24

Click “Yes” to start the Acrobat reader installation and follow the instructions.
Finally, the “Complete” screen display.

datacolor Formulation Software Match Textile - fig 25

Click “ Finish ” to restart your computer.
Datacolor MONITOR is now installed on your system!

Validating Datacolor Software

Datacolor Spectrum Software is protected from unauthorized use by a software license. When the software is initially installed, the software license is in a demo period that will allow access for a fixed amount of time. In order to run the software after the demo period, the software license must be validated.
There are a number of ways to validate the software. In general you will need the following information:

  1. You will need the Serial Number for your software. This number is supplied by Datacolor and is found on the USB case.
  2. You will need a Computer Validation Number. This number is generated by the security software and is unique to your computer.

Validation information is accessed and input in the Datacolor Validation Window shown below:
datacolor Formulation Software Match Textile - fig 26
Datacolor Tools will display the Validation Window every time it starts during the demo period. The Validation Window can be accessed from “About” window in Datacolor Tools, select “License Info”.
You can validate the software in 3 ways:

  • Using a Web Connection – Link is on the Validation Window. Example is shown below
  • E-Mail – Send Serial Number and Computer Validation Number for the product to [email protected]. You will receive an Unlock Response Number by e-mail that you will put into the Validation Window.
  • Phone – In the US and Canada phone toll free 1-800-982-6496 or call you local sales office. You will need the Serial Number and the Computer Validation Number for the product. You will be given an Unlock Response Number that you will put into the Validation Window.

datacolor Formulation Software Match Textile - fig 27

datacolor Formulation Software Match Textile - fig 28

Click the Continue button.

datacolor Formulation Software Match Textile - fig 29

ODBC Data Source Administrator
datacolor Formulation Software Match Textile - fig 30datacolor Formulation Software Match Textile - fig
31 After you have entered the Unlock Response Number into the Validation Screen, your software is validated. You can validate additional programs by selecting the Validate Another option
ODBC Data Source Administrator

Datacolor MATCH MONITOR™ Stand-Alone Installation Guide (July 2021)
All efforts have been made to ensure the accuracy of the information presented in this format. However, should any errors be detected, Datacolor appreciates your efforts to notify us of these oversights.
Changes are periodically made to this information and are incorporated into forthcoming versions. Datacolor reserves the right to make improvements and/or changes in the
product(s) and/or program(s) described in this material at any time.
© 2008 Datacolor. Datacolor, SPECTRUM and other Datacolor product trademarks are the property of Datacolor.
Microsoft and Windows are either registered trademarks of Microsoft Corporation in the United States and/or other countries.
To obtain information on local agents, contact either of the offices listed below, or visit our website at www.datacolor.com.

Support Questions?
If you need help with a Datacolor product, please contact one of our top-rated technical support teams located around the world for your convenience. You can find contact
information below for the Datacolor office in your area.

Americas
+1.609.895.7465
+1.800.982.6496 (toll-free)
+1.609.895.7404 (fax)
NSA[email protected]

Europe
+41.44.835.3740
+41.44.835.3749 (fax)
[email protected]

Asia Pacific
+852.2420.8606
+852.2420.8320 (fax)
[email protected]
Or Contact Your Local Representative
Datacolor has representatives in over 60 countries.
For a complete list, visit www.datacolor.com/locations.
Manufactured by Datacolor
5 Princess Road
Lawrenceville, NJ 08648
1.609.924.2189
Committed to Excellence. Dedicated to Quality.
Certified to ISO 9001 in Manufacturing Centers Worldwide.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

datacolor User Manuals

Related Manuals