Datacolor 650 Spectro 55 User Guide
- September 16, 2024
- datacolor
Table of Contents
Datacolor 650 Spectro 55
Product Information
Specifications
- Model: Datacolor Spectro 55
- Measurement Geometry: 45/0
- Application: Retail paint measuring
- Compatibility: Datacolor Paint software or retail software
Product Usage Instructions
About the Datacolor Spectro 55 Instrument
The Datacolor Spectro 55 instrument is the latest model designed for retail
paint applications. It offers accurate and quick measurements to create high-
quality custom color matches.
Integration
The instrument can be easily integrated with Datacolor Paint software or your
own retail software, allowing for efficient operation and increased
profitability.
Controls and Indicators
The instrument features a status panel and a measurement button for easy
operation.
Calibration
It is important to calibrate the instrument regularly for accurate
measurements. Refer to the user manual for detailed instructions on
calibration with Datacolor Paint software.
Instrument Setup
Follow the instructions in the user manual for setting up the instrument
with Datacolor Paint software or your preferred retail software.
FAQ
-
Q: How often should I calibrate the Datacolor Spectro 55?
A: It is recommended to calibrate the instrument before each color measurement session to ensure accurate results. -
Q: Can the Datacolor Spectro 55 be used for applications other than retail paint?
A: The instrument is specifically designed for retail paint applications, and its accuracy may vary for other types of materials.
Datacolor Spectro 55 User’s Guide
Part No.1030-1654 Rev A, October 1, 2024
All efforts have been made to ensure the accuracy of the information presented
in this format. However, should any errors be detected, Datacolor appreciates
your efforts to notify us of these oversights.
Changes are periodically made to this information and are incorporated into
forthcoming versions. Datacolor reserves the right to make improvements and/or
changes in the product(s) and/or program(s) described in this material at any
time.
© 2024 Datacolor. Datacolor, SPECTRUM and other Datacolor product trademarks
are the property of Datacolor.
Microsoft and Windows are either registered trademarks of Microsoft
Corporation in the United States and/or other countries.
To obtain information on local agents, contact either of the offices listed
below or visit our website at www.datacolor.com.
Support Questions?
If you need help with a Datacolor product, please contact one of our top-rated
technical support teams listed below for the Datacolor office in your area.
Datacolor Spectrophotometers
About the Datacolor Spectro 55 Instrument
The Datacolor Spectro 55 instrument is the newest generation of Datacolor’s
retail paint measuring instruments. This 45/0 measurement geometry instrument
is intended for retail paint applications.
Use Datacolor Spectro 55 to quickly and accurately measure samples to produce
quality custom color matches.
Easy integration with Datacolor Paint software or your own retail software,
this solution reduces your cost of operation and increases your profitability.
Datacolor Spectro55
Below is a summary of the features included with the instrument.
Features include the following:
- 45/0 Geometry or d8 SCI Mode
- Simple calibration with built-in calibration tile.
- Stainless steel aperture plate, for cleaning.
- Sample viewing port for easy sample alignment.
- Built-in measurement button.
- Calibration indicator light.
Electrical/Environmental Requirements
Input Power Requirements | 5V DC, 150 mA |
---|---|
Operating Environment | Temperature: 5°C to 40°C |
Maximum Relative Humidity : 20%-85% non-condensing
Altitude: Up to 2,000 meters
Do not store above 140°F (60°C) Indoor Use
Do not crush, short circuit, mutilate, reverse polarity, disassemble, or dispose.
Safety Features
If the equipment is used in a manner not specified by the manufacturer, the
protection provided by the equipment may be impaired.
CAUTION
There are no user-serviceable parts for this equipment.
-
Light Source
Do not stare directly into the open port of the instrument when the measurement is in progress. -
Power
The USB-C cord supplied with the unit must be used to connect to an earthed (grounded) power supply.
The power cord supplied with the unit must be used.
CAUTION Disconnect power before servicing.
Feature Summary
This instrument employs state-of-the-art features including the
spectrometer, light source, and optics. Below is a summary of those features:
Datacolor Spectro 55
Instrument Type| 45/0 Spectro
Geometry Output| 45/0 Mode of d8 SCI Mode
Light Source| LED
Spectral Analyzer| 8 Channel sensor with dual illumination
Repeatability (Max on White Tile)| 0.03 SD / 0.10 Mas CIE2000
IIA (32 Master Standard Tiles)| 45/0Mode IIA CIE2000 0.3 avg / CIELAB 0.4 avg
SCI Mode IIA CIE2000 0.4 avg / CIELAB 0.6 avg
Wavelength Range| 400nm – 700nm
Aperture Size| 6 mm
Reporting Interval| 10 nm
Data Interface| USB
Accessories
All models come with the following standard accessories:
- Power cable
- Micro USB to USB C cable
Calibration Tile
The white calibration tile is embedded into the sample arm and covered with
a protective cap. Protective cap will be removed only when calibrating, and
returned to keep the tile clean and safe from damage.
Cable Installation
Overview
Datacolor Spectro 55 required 2 cables, a power cable and USB cable that
connects the instrument to a PC.
Both are plugged into the back of the instrument.
WARNING
Turn off the power before working with any cables.
Read the “Electrical and Environmental Requirements” section BEFORE connecting
your instrument.
Power Supply
Must use supplied Wall mounted AC/DC power adapter.
You need an AC Plug adapter that is specific to your geographical location.
This is specified as part of the shipment. AC Clips are available for Greater
China, North America, South America, Europe, India Subcontinent and Southeast
Asia
- Power Cable Connection
Plug the end of the barrel jack power cord into the power receptacle on the rear panel of the instrument. Insert the plug into a standard AC outlet.
NOTE The cable supplied with the instrument must be used. No other cords are acceptable.
Communications Cable
The instrument is connected to a computer through a Micro USB to USB-C
port.
- USB Cable Connection
To connect the instrument to the computer using the supplied cable:
1. Connect the Micro USB cable to the connector on the instrument.
2. Connect the USB-C cable to the computer.
Power Switch
The power switch is located on the back of the instrument at the bottom
end.
Controls and Indicators
Status Panel
- Power – Green light indicates Power On
- Calibration – Indicates if the calibration interval has expired.
- Red Light – Calibration has elapsed. Recalibrate instrument to ensure an accurate measurement.
- Green Light – Instrument is calibrated.
Measurement Button
- On board measurement button:
- Able to trigger a measurement from the instrument.
Instrument Calibration
General Calibration Information
Datacolor Spectro 55 must be calibrated regularly to ensure that the
measurements are accurate. This section provides instructions for performing a
calibration with Datacolor Paint
NOTE The recommended calibration interval for the Spectro 55 with Datacolor Paint is every 24 hours to account for any changes in the device over time. The instrument is calibrated through the attached software.
Calibration Data
No calibration data is required for the Spectro 55.
Instrument Setup for Datacolor Paint
Datacolor Spectro 55 device must be added to the manufacturers database via
Datacolor Paintlab software.
Paint 2.x
- Select Configuration Settings/Devices/Spectrophotometer
- Select the Spectro 55 from the list (Accept All)
- Restart Paint if instructed
- Before connecting, ensure that the device is on and linked to the PC through the USB cable. Click Connect when prompted.
- Your device is ready to be Calibrated and used.
Instrument Calibration with Datacolor Paint
- Select – Calibrate.
- Remove white tile Cover from sample arm. ****
- Close sample arm.
- Select – Click to calibrate now
- Calibration Succeeded – Click Get ready to measure
- Calibration Failed – Check white tile is up against spec port, Repeat Step 4
Measurement
Sample Presentation and Measurement
When measuring samples using Datacolor Spectro 55, you must pay close
attention to the positioning of the sample to insure an accurate measurement.
When positioned correctly, the sample rests between the sample holder and the
front panel door. The sample must completely cover the aperture opening.
To position the sample:
- Grasp the sample holder and pull forward.
- Position the sample at the port.
- Return the sample holder to the upright position.
Sample Presentation and Measurement
When measuring small samples, you may need to verify that the correct area
of the sample is being measured.
To check the sample area being viewed by the lens:
- Grasp the tab above the aperture plate.
- Pull the tab down to its full horizontal position. Look at the backside of the door to see the area of the port opening that is covered by the sample. If necessary, adjust the placement of the sample to properly position the sample area to be measured. The sample must completely cover the port opening.
- Push the door back to its normal position, and start the measurement.
Appendix
Datacolor Global Support
A complete User’s Guide is provided with this product. However there are
also resources regarding color education on the Datacolor website, including
contact information for local Datacolor offices.
http://industrial.datacolor.com/support/contact-us-2/
References
- Color Management Tools - Color Management | Datacolor
- Color Management Tools - Color Management | Datacolor