Features

  • Constant current design
  • Universal AC input / Full range
  • Protections:Short circuit / Over voltage
  • Fully isolated plastic case
  • Small and compact size
  • Cooling by free air convection
  • Class II power unit, no FG
  • Class 2 power unit
  • Pass LPS
  • IP42 design
  • Suitable for LED related fixture or appliance (such as LED Decoration or Advertisement devices)(Note.6)
  • 100% full load burn-in test
  • Low cost / High reliability
  • 2 years warranty

Icons

SPECIFICATION

MODEL APC-12-350 APC-12-700

OUTPUT

| RATED CURRENT| 350mA| 700mA
DC VOLTAGE RANGE| 9~36V| 9~18V
RATED POWER| 12.6W| 12.6W
RIPPLE & NOISE (max.) **Note.2| 300mVp-p| 250mVp-p
VOLTAGE TOLERANCE Note.3| ±5.0%
CURRENT ACCURACY| ±8.0%
LINE REGULATION| ±1.0%
LOAD REGULATION| ±3.0%
SETUP, RISE TIME| 3000ms, 180ms / 230VAC          3000ms, 150ms / 115VAC at full load
HOLD UP TIME (Typ.)**| 20ms/230VAC,15ms/115VAC at full load

INPUT

| VOLTAGE RANGE Note.4| 90 ~ 264VAC           127 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
EFFICIENCY(Typ.)| 82%| 80%
AC CURRENT| 0.2A/230VAC;0.35A/115VAC
INRUSH CURRENT(Typ.)| COLD START 70A(twidth=120μs measured at 50% Ipeak) at 230VAC
MAX. No. of PSUs on 16A CIRCUIT BREAKER| 17 units (circuit breaker of type B) / 29 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT| 0.25mA / 240VAC
PROTECTION| OVER VOLTAGE| 39.6~ 46.8V| 20.7~ 24.3V
Protection type : Shut off o/p voltage, clamping by zener diode
ENVIRONMENT| WORKING TEMP.| -30 ~ 70℃(Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.2%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC

(Note 5)

| SAFETY STANDARDS Note.7| UL8750,CSA C22.2 No.250.0-08, BIS IS15885, EAC TP TC 004 approved; design refer to BS EN/EN 62368-1
WITHSTAND VOLTAGE| I/P-O/P:3.75KVAC
ISOLATION RESISTANCE| I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Compliance to BS EN/EN55032,BS EN/EN61000-3-2,BS EN/EN61000-3-3, EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN55024,BS EN/EN61000-4-2,3,4,5,6,8,11; light industry level(surge 2KV), criteria A, EAC TP TC 020

OTHERS

| MTBF| 1145.7K hrs min.       MIL-HDBK-217F (25℃)
DIMENSION| 774029(LWH)
PACKING| 0.08Kg; 120pcs/11.8Kg/1.06CUFT
NOTE| 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1 of & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristic for more details.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. This product is not intended for LED lighting luminaire applications in the EU.(In the EU the LPF/NPF/XLG series are recommended.)
7. The model certified for CCC(GB19510.14, GB19510.1, GB17743 and GB17625.1) is an optional model . Please contact MEAN WELL for details.
8. The ambient temperature derating of 3.5°C/1000m with fanless models and of 5°C/1000m with fan models for operating altitude higher than 2000m(6500ft). 9. For any application note and IP water proof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf Product Liability Disclaimer : For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Product Liability Disclaimer For detailed information , please refer to https ://www . meanwell . com / serviceDisclaimer . aspx

Mechanical Specification

Mechanical Specification

Block Diagram

Block Diagram

Derating Curve

Derating Curve

Static Characteristics

EFFICIENCY vs LOAD (APC-12-350)

EFFICIENCY vs LOAD

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals

Related Manuals