INSTALLATION INSTRUCTION

PREPARE DOOR

  • Prepare door and frame according to template.
  • Refer to trim template if installing trim.

SIZE DEVICE

  • Standard lengths are for 36″ or 48″ door. Device must be cut for other lengths.
  • Mark length with tape – length equals device size minus desired door size (for 30″ door = cut 6″ off 36″ device) ensuring a square cut.

Maximum cut off length:

 | Panic| Fire| Alarm| MLR
36″ Device| 6″| 8″| 2″| 3″
48″ Device| 12″| 14″| 8″| 9″

 INSTALL DEVICE
  • Install device and trim with 1/4-20 screws from pack #639043.
  • Device can be surface mounted to the door, optional sex nuts are available, device is through bolted if using trim.

INSTALL END CAP

  • Slide end cap into rail. Ensure rail is level. Mark the centers of the slots.
  • Remove end cap then drill holes using the chart from Step 3.
  • Reinstall end cap and fasten with screws.

INSTALL HEAD COVER

  • Slide head cover onto exit device
  • Install 4 mounting screws

INSTALL STRIKE

  • Install strike with roller toward door face using two #10-24 pan head screws.
  • Adjust strike to secure door.
  • Install flat head locking screw by drilling and tapping for #10-24 after final adjustment is achieved.