FS S5860-24MG-U Port Ethernet L3 Poe Switch
Introduction
Thank you for choosing the S5860 Series Ethernet L3 Switches. This guide is designed to familiarize you with the layout of the switches and describes how to deploy them in your network.
Accessories
S5860-48XMG-U
NOTE: This power cord cannot be used with other devices, and other power cords should not be used with this device.
S5860-24MG-U
NOTE
- The accessories may vary from illustration, please prevail in kind.
- This power cord can not be used with other devices, and other power cords should not be used with this device.
Hardware Overview
Front Panel Ports
S5860-48XMG-U
Ports | Description |
---|---|
RJ45 | Multi-GE electrical ports for 100M/1G/2.5G/5G/10G connection |
SFP28 | SFP28 ports for 10G/25G connection |
QSFP+ | QSFP+ ports for 40G connection |
S5860-24MG-U
Ports | Description |
---|---|
Console | An RJ45 console port for serial management |
MGMT | An out-of-band Ethernet management port |
RJ45 | 100M/1G/2.5G/5G electrical ports for Ethernet connection. All ports |
support the PoE function
SFP28| SFP28 ports for 10G/25G connection
USB| A USB management port for online upgrade or log storage
Front Panel LEDs
S5860-48XMG-U
S5860-24MG-U
LEDs | State | Description |
---|
LED Mode
| Solid Green| The LED indicates the switching status.
Solid Amber| The LED indicates the PoE power supply status.
FAN
| Solid Green| All fan modules are seated and functioning properly.
Solid Red
| • One fan module is faulty.
• The fan module model is not supported.
• One fan module is not seated.
PWR1/PWR2
| Off| The power module is not seated.
Solid Green| The power module is seated and providing power to the switch.
Solid Amber| The model of the power module is not supported or cannot be read.
Solid Red
| The redundant power module is not functioning properly or not connected to the AC power cord.
MGMT
| Off| No link is established on this port.
Solid Green| A 1000Mbps link is established on this port.
Blinking Green| The port is sending and receiving traffic at 1000Mbps.
Solid Amber| A 100/1OMbps link is established on this port.
Blinking Amber| The port is sending and receiving traffic at 100/1OMbps.
Status
| Off| The system is not powered on.
Blinking Green (3Hz)| The system is being initialized. Continuous blinking
indicates a fault.
Blinking Green (10Hz)
| The system is being located, and can be remotely turned on or off by an O&M
engineer.
Solid Green| The system is operating normally.
Solid Amber| Temperature at the air intake and exhaust vents exceeds the
threshold.
Status
|
Solid Red
| • Temperature at air inlets or outlets exceeds the threshold.
• The system is faulty.
---|---|---
RJ45
| Off| No link is established on this port.
Solid Green
| S5860-48XMG-U| A 1/2.5/5/10Gbps link is established on this port.
S5860-24MG-U| A 1/2.5/5Gbps link is established on this port.
Blinking Green
| S5860-48XMG-U| The port is sending or receiving traffic at 1/2.5/5/10Gbps.
S5860-24MG-U| The port is sending or receiving traffic at 1/2.5/5Gbps.
Solid Amber| A 100Mbps link is established on this port.
Blinking Amber| The port is sending and receiving traffic at 100Mbps.
PoE Status
| Off| S5860-48XMG-U/ S5860-24MG-U| The PoE function is disabled.
Solid Green| The PoE function is enabled.
Solid Amber| The PoE port is overloaded or faulty.
SFP28
| Off| No link is established on this port.
Solid Green| A 10/25Gbps link is established on this port.
Blinking Green| The port is sending and receiving traffic at 10/25Gbps.
QSFP+
| Off| No link is established on this port.
Solid Green| A 40Gbps link is established on the port.
Blinking Green| The port is sending and receiving traffic at 40Gbps.
Front Panel Button
S5860-48XMG-U
S5860-24MG-U
Button | Description |
---|---|
LED Mode | Press it for over two seconds to switch the LED mode. |
Back Panel Ports
S5860-48XMG-U
Ports | Description |
---|---|
MGMT | An out-of-band Ethernet port |
Console | An RJ45 console port for serial management |
USB | A USB management port for online upgrade or log storage |
Installation Requirements
Before the installation, make sure that you have the following conditions ready:
- Phillips screwdriver, related bolts and ESD tools.
- Standard-sized, 19″ wide rack with a minimum of 1 U height available.
- Category 5e or higher RJ45 Ethernet cables, fiber optic cables, and a console cable.
Site Environment
- Ensure that the temperature of the installation site is maintained at 0’C~45’C.
- Ensure that the operating humidity is maintained at 10%~90%.
- The installation site must be free from leaking, dripping water, heavy dew, or humidity.
- Keep the installation site dust-free.
- The installation site must be well-ventilated. Ensure that there is adequate airflow around the switch.
- Ensure that the switch is level and stable to avoid any hazardous conditions.
- Ensure that the rack and the working platform are firm enough to support the weight of a switch and its accessories for installation.
- Ensure that the rack and the working platform are well-earthed.
Mounting the Switch
Desk Mounting
- Attach four rubber pads to the bottom of the switch.
- Place the switch on a stable desk.
NOTE
- Do not place heavy objects on the switch.
Rack Mounting
S5860-48XMG-U
- Secure the front mounting brackets and the sliding rails to the two sides of the switch with screws.
- Fix the rear mounting brackets to the rack with screws and cage nuts.
- Slide the switch into the rack.
- Install the switch on the rack with screws and cage nuts.
NOTE
- Please prepare the screws and cage nuts separately.
S5860-24MG-U
- Secure the front mounting brackets to the switch with screws.
- Attach the switch to the rack with screws and cage nuts.
Grounding the Switch
- Connect one end of the grounding cable to a proper earth ground, such as the rack in which the switch is mounted.
- Secure the grounding lug to the grounding point on the switch with a screw and washers.
CAUTION
- The earth connection must not be removed unless all supply connections have been disconnected.
Connecting the RJ45 Ports
- Connect one end of an Ethernet cable to the RJ45 port of a network device.
- Connect the other end of the Ethernet cable to the RJ45 port of the switch.
Connecting the SFP28 Ports
- Plug a compatible SFP28 transceiver into the SFP28 port on the switch.
- Connect a fiber optic cable to the fiber transceiver. Then connect the other end of the cable to another fiber device.
Connecting the QSFP+ Ports
- Plug the compatible QSFP+ transceiver into the QSFP+ port on the switch.
- Connect a fiber optic cable to the fiber transceiver. Then connect the other end of the cable to another fiber device.
Connecting the Console Port
- Insert the RJ45 connector into the RJ45 console port of the switch.
- Connect the D89 female connector of the console cable to the serial port on the computer.
Connecting the MGMT Port
- Connect one end of the Ethernet cable to a computer.
- Connect the other end of the cable to the MGMT port on the switch.
Connecting the USB Port
- Insert the Universal Serial Bus (USB) flash disk into the USB port of the switch.
Connecting the Power
- Plug the AC power cord into the power port on the switch.
- Connect the other end of the power cord to an AC power source.
WARNING: Do not install the power cord while the power is on.
Troubleshooting
The AC Power Module Is Abnormal
All LEDs on the front panel are off. The fan status LED is off. The power supply status LED is off. The fan does not rotate.
- Unplug the power cord from the power module.
- Check the cable connection.
- Check whether the power cord is tightly connected to both the power socket and the power module.
- Check whether the power module is securely seated. If necessary, pull out the power module and check its connector.
No Output for the Console Port
- Check whether the console cable is properly connected.
- Ensure that the connected console port is consistent with what is configured on the HyperTerminal.
- Check whether the configuration of the console port on the HyperTerminal is correct.
The Optical Port Link Is Down
- Check whether the receiving end and transmitting end are reversed. Confirm both ends by exchanging the connection order of two fiber optic cables.
- Check whether the wavelengths of optical modules on two sides are consistent.
- Check whether the distance between the two sides exceeds the maximum length marked on the optical module.
- Check whether the speeds of the two sides match and whether the optical fiber type meets the requirements.
Online Resources
- Downloadhttps://www.fs.com/products_support.html
- Help Centerhttps://www.fs.com/service/fs_support.html
- Contact Ushttps://www.fs.com/contact_us.html
Product Warranty
FS ensures our customers that for any damage or faulty items due to our workmanship, we will offer a free return within 30 days from the day you receive your goods. This excludes any custom-made items or tailored solutions.
- Warranty: The products enjoy a 5-year limited warranty against defects in materials or workmanship. For more details about the warranty, please check at https://www.fs.com/policies/warranty.html
- Return: If you want to return the item(s), information on how to return can be found at https://www.fs.com/policies/day_return_policy.html
FCC STATEMENT
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. This device complies with part 15 of the FCC Rules. Operatiois subject to the following two conditions:
- This device may not cause harmful interference.
- This device must accept any interference received, including interference that may cause undesired operation.
CE
Warning: This is a class A product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures.
FS.COM GmbH hereby declares that this device is in compliance with the Directive 2014/30/EU, 2014/35/EU, 2011 /65/EU and (EU)2015/863 .A copy of the EU Declaration of Conformity is available at www.fs.com/company/quality_control.html.
FS.COM GmbH
- NOVA Gewerbepark Building 7, Am Gfild 7, 85375 Neufahrn bei Munich, Germany
S5860-48XMG-U
- Caution shock hazard, disconnect all power sources.
UKCA
Hereby, FS.COM Innovation Ltd declares that this device is in compliance with the Directive SI 2016 No. 1091, SI 2016 No. 1101,SI 2012 NO. 3032.
FS.COM INNOVATION LTD
- Unit 8, Urban Express Park, Union Way, Aston, Birmingham, 86 7FH, United Kingdom
ISED
CAN ICES-003(A)/NMB-003(A)
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions:
- This device may not cause interference.
- This device must accept any interference, including interference that may cause undesired operation of the device.
The digital apparatus complies with Canadian CAN ICES-003(A)/NMB-003(A).
Waste Electrical and Electronic Equipment (WEEE)
This appliance is labelled in accordance with European Directive 2012/19/EU concerning waste electrical and electronic equipment (WEEE). The Directive determines the framework for the return and recycling of used appliances as applicable throughout the European Union. This label is applied to various products to indicate that the product is not to be thrown away, but rather reclaimed upon end of life per this Directive.
To avoid the potential effects on the environment and human health as a result of the presence of hazardous substances in electrical and electronic equipment, end users of electrical and electronic equipment should understand the meaning of the crossed-out wheeled bin symbol. Do not dispose of WEEE as unsorted municipal waste and have to collect such WEEE separately.
Equipment Grounding Warning
This equipment must be grounded. To reduce the risk of electric shock, never
defeat the ground conductor or operate the equipment in the absence of a
suitably installed ground conductor.
Contact the appropriate electrical inspection authority or an electrician if
you are uncertain that suitable grounding is available.
Lithium Battery Precautions
Lithium Battery Caution
- There is a danger of explosion if a battery is incorrectly replaced. Replace only with the same or equivalent type. Dispose batteries of according to the manufacturer’s instructions.
- Disposing a battery into fire, a hot oven, mechanically crushing, or cutting it can result in an explosion.
- Leaving a battery in an extremely hot environment can result in leakage of flammable liquid, gas, or an explosion.
- If a battery is subjected to extremely low air pressure, it may result in leakage of flammable liquid, gas, or an explosion.
- Installation should be done only by a trained electrician who knows all installation procedures and device specifications.
- Do not ingest battery. Chemical burn hazard. This product contains a coin/ button cell battery. If the coin/button cell battery is swallowed, it can cause severe internal burns in just 2 hours and can lead to death. Keep new and used batteries away from children. If the battery compartment does not close securely, stop using the product and keep it away from children. If you think batteries could have been swallowed or placed inside any part of the body, seek immediate medical attention.
Q.C. PASSED
Copyright© 2024 FS.COM All Rights Reserved.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>