Introduction

FS M6200 Series Platform provides a managed, flexible and scalable architecture for fiber networks.
It can support EDFA, OEO, OLP, DCM and other M6200 Series Infrastructure Modules to construct a multi-service optical transmission network platform.

FS M6200 Series WDM Network - fig

M6200 Series Platform Overview

M6200 Series Infrastructure Modules
1-Slot Card Type

FS M6200 Series WDM Network - fig 2FS M6200
Series WDM Network - fig 3

2-Slot Card Type

FS M6200 Series WDM Network - fig 4

NOTE:

  1. M6200 series modules are designed as 1-slot card type or 2-slot card type to match the managed c h a s s i s .
  2.  1-slot module: OEO, DWDM EDFA, OLP, DWDM Red/Blue Filter, DCM(40km), OSC, NMU, etc.
  3.  2-slot module: MUX, DEMUX, DCM(80km).

M6200 Series Managed Chassis

FS M6200 Series WDM Network - fig 5

Chassis Type Chassis Slot
M6200-CH2U 7pcs
M6200-CH5U 15pcs

Accessories

FS M6200 Series WDM Network - fig 6

FS M6200 Series WDM Network - fig 7

DWDM Mux Demux Module

FS M6200 Series WDM Network - fig 8

Front Panel Port

Port Port Type Description
C21-C60 LC/UPC Mux/Demux Channel Port
OUT Optical Singal Output Port
IN Optical Signal Input Port
MON Input/output Optical Power Monitoring Port

DWDM EDFA (Erbium Doped Fiber Amplifier)

FS M6200 Series WDM Network - fig 9

Front Panel Port

Port Port Type Description
VOA Port SFP Optical Power Attenuation Adjusting Port for SFP VOA
OUT LC/UPC Optical Signal Output Port
IN Optical Signal Input Port
Osco Optical Supervisory Channel Output Port
Orc Optical Supervisory Channel Input Port
MON Optical Signal Monitoring  Port
CONSOLE Micro USB Debugging & Upgrading Port

Front Panel LED

LED Alarm State Normal State Description
ALM Always ON:
There is  alarm of  the power supply, the fan or the NMU module. Light  OFF

Module  State  Alarm
Quick Flash:
The module type does not match.
RUN| Always OFF:
The module is not normally enabled.| Slow  Flash| Module Run
IN| Always Red:
There is  LOS alarm of the port.| Always Green| Input Optical Pal owner Alarm
OUT| Always OFF:
The port is  not enabled.

10G OEO Transponder

FS M6200 Series WDM Network - fig 10

Front Panel Port

Port Port Type Description
Port1~10  SFP/SFP+ Optical Transceiver Signal Transmitting Port

Front Panel LED

LED Status Description
SYS S l o w  Flash of Green Light There is no alarm o f  the module.
Quick Flash of Red Light The module type d o e s  not match.
S l o w  Flash of Red Light There is alarm of the module.
Always Red The module i s  enabling.
1~10 Always Green There is no LOS alarm of the port.
Always Red There is LOS alarm o f  the port.
Always OFF The port is disabled.

Signal Protocol

Service Type Rate
STM-1 SDH Service 155.52Mbit/s
STM-4 622.08Mbit/s
STM-16 2.488Gbit/s
STM-64 9.95 Gbit/s
ESCON SAN Service 200Mbit/s
FC100 1,06Gbit/s
FC200 2.12Gbit/s
DVB-ASI. SDL Digital TV Service 270Mbit/s
HD-SDI HDTV Service 1.485Gbit/s
GE Ethernet Service 1.25Gbit/s
FE 125Mbit/s
CPRI Option1 0.6144Gbit/s
CPRI Option2 1 . 2 2 8 8 G bit/s
CPRI Option3 2.4576Gbit/s
10GE LAN 10.31Gbit/s
10GE WAN 9.95Gbit/s
oTu2 OTN Service 10.71Gbit/s
OTU2e 11.1Gbit/s

100G OEO Transponder

FS M6200 Series WDM Network - fig 11

Front Panel Port

Port Port Type Description
Port 1~6 QSFP+/QSFP28 40/100Gbps Optical Transceiver Signal Transmitting

Port

Front Panel Port

LED Status Description
ALM Always Red There is alarm of the Power, Fan and NMU module.
Quick Flash of Red Light There module type does not match.
Always OFF There is no alarm of the module.
RUN Slow  Flash of Green Light The module is normal.
Always OFF The module does  not work.
1-6 Always Green There is no LOS alarm o f  the port.
Always Red There is LOS alarm of the port.
Quick Flash of Red Light The transceiver does not match.
Always OFF The port is  disabled.

DCM (Dispersion Compensation Module)

FS M6200 Series WDM Network - fig 12

Front Panel Port

Port Port Type Description
OUT LC/UPC Optical Signal Output Port
IN Optical Signal Input Port

OSC Module (Optical Supervisory Channel Module)

FS M6200 Series WDM Network - fig 13

Front Panel Port

Port Port Type Description
IN1/2 LC/UPC Transmission Line Side Optical Signal Input Port
OUT1/2 Transmission Line Side Optical Singal Output Port
OSCI1/OSCI2 Optical Supervisory Channel Input Port
0SCO01/0SCO2 Optical Supervisory Channel Output Port
TX1/2 WDM Demultiplexing Optical Signal Input Port
RX1/2 WDM Multi plexin  Optical Signal Output Port

1+1 OLP (Optical Line Protection)

Front Panel Port

Port Port Type Description
TX/RX LC/UPC Input/output Port Connected to the Transmission Equipment
TI/R1 Main  Optical Signal Transmitting Port/Receiving Port
T2/R2 Backup Optical Signal Transmitting Port/Receiving Port
CONSOLE Micro USB Debugging & Upgrading Port

Panel Key Instruction

Key Function Description
AUTO/FORCE Press for switching  auto mode or manual mode Switching Working

Mode
PRI/SEC| Press for switching  work channel of  primary/second state| Switching Working Channel

Front Panel LED

LED Status Description
ALM Always ON There is alarm of the sub-module.
Quick Flash The module type does  not match.
Always OFF The alarm does not exist.
RUN S l o w  Flash The module works normally.
Always OFF The module is not normally enabled.
A/F Always ON The module is in  automatic mode.
Always OFF The module is in  manual mode.
P/S Always ON The line is  in  primary channel state.
Always OFF The line is  in  secondary channel state.
TX/R1/R2 Always ON The line power is normal.
Always OFF The line power is lower than the threshold.

Managed Chassis

FS M6200 Series WDM Network - fig 15

Front Panel Port

Slots Description
NMU Module Network Management Unit (NMU) ,  the main control module of

chassis
Blank Plate 1| Used for 1+1 NMU module backup or M6200 series business module
Blank Plate 2~7| Used  for 1-slot/2-slot M6200 series business module
Fan| Support field-replaceable and hot-swappable
AC Power| AC power supply, 90VAC~264VAC, 45Hz~65Hz, supports 1+1 backup

FS M6200 Series WDM Network - fig 16

Front Panel Port

Slots Description
NMU Module Network Management Unit(NMU), the main control module of chassis
Blank Plate 1 Only used for 1+1 NMU module backup
Blank Plate 2~15 Used  for 1-slot/2-slot M6200 series business module
Fan Support field-replaceable and hot-swappable
AC Power AC power supply, 110VAC~260VAC, 45Hz~65Hz, supports 1+1 backup

Networking Management Unit

FS M6200 Series WDM Network - fig 17

Front Panel Port

Port Port Type Rate Description
MGMT 1~4 fu45 ETH 10/100M
Auto-negotiate Connect to the local network management computer

Interface for NMS concatenation equipment
MGMT5~6| SFP| 100M| Out of band OSC management
CONSOLE| RJ45 ETH| /| Debugging & Upgrading port

Front Panel LED

LED Status Description
ALM Always ON There is alarm on the power supply, the fan or the NMU Module.
Always OFF There is no alarm.
RUN Quick Flash The module works normally.
Always OFF The module is  not normally  enabled.
ACT Always ON The module is  the primary module.
Always OFF The module is  the secondary module.

Site Environment

  • Keep the equipment’s indoors. If it is in rainy season or in humid environment, dehumidification measures must be taken.
  • Ensure there is no water on the storage floor and no leakage to the packing box of the equipment.
  • Avoid automatic fire fighting facilities, heating system and other places where leakage may occur.

Installing

Wearing ESD Wrist Strap

FS M6200 Series WDM Network - fig 18

  1. Before touching any device or module, wear an ESD wrist strap or ESD gloves to protect sensitive components against electrostatic discharge from the human body.
  2. Connect other end of the ESD wrist strap to the PGND point on the chassis.

Installing Business Module

FS M6200 Series WDM Network - fig 19

  1. Hold the ejector levers on the front panel of the module and raise them.FS M6200 Series WDM Network - fig 20
  2. Push the module gently along the guide rail until the module cannot go any further. Then lower the two ejector levers of the module.

Installing Mounting Brackets

FS M6200 Series WDM Network - fig 21

  1. Secure the mounting brackets to the two sides of the M6200 series managed chassis with 8x M4 screws.

Rack Mounting

FS M6200 Series WDM Network - fig 22

  1. Put the M6200 series managed chassis on the shelf in the cabinet.
  2. Install and tighten the panel with 4 sets of M6 screws.
  3. Cable manager can be installed together with mounting brackets to the cabinet.

Grounding the M6200 Series Managed Chassis

FS M6200 Series WDM Network - fig 23

  1. Secure the grounding lug to the grounding point on the chassis front panel with the washers and screws,
  2. Connect the other end of the cable to a proper earth ground, such as the rack in which M6200 series is mounted.
    CAUTION: The earth connection must not be removed unless all supply connections have been disconnects.

Connecting Power Cord

FS M6200 Series WDM Network - fig 24

  1. Plug AC power c o r d into the power port on the front panel of AC power module.
  2. Connect the other end of the power cord to an AC power source.
    WARNING: Do not install power cables while the power i s on.

Connecting to the Management Ports
SFP Management Port

FS M6200 Series WDM Network - fig 25

  1. Plug the compatible SFP transceiver into the SFP port on the front of NMU module.
  2. Connect a fiber optic cable to the transceiver. Then connect the other end of the cable to another fiber device, such as a switch.

RJ45 Management port

FS M6200 Series WDM Network - fig 26

  1. Connect one end of the standard RJ45 Ethernet cable to the MGMT1&2 port on the front of NMU module.
  2. Connect the other end of cable to a computer.

NOTE:

  1. SFP management port is designed for long-haul management more than 100m.
  2.  RJ45 management port is designed for short-haul management less than 100m,
  3. You can start your management by selecting one cf the above six management ports.

Configuring the M Series Platform

Configuring the M Series Platform Using the Web-based Interface
Step 1: Connect your computer with the network cable to any Ethernet MGMT port of the NMU module.
Step 2: Get the NMS software frown the USB Flash Drive of chassis accessories or download the file NMS software” online, and then install it.

Step 3: Double Click” NMS Server’ icon on the desktop and the dialogue box of license validation will pop up. Enter the license key (included in the USB Flash Drive) to finish validation. (If you can’t find the license key, please contact FS sales manager for help.)

FS M6200 Series WDM Network - fig 28

Step 4: Then the NMS server interface pops up. Double click “Start NMS Server” to run the server, when it prompts “Please connect your client to the web server on port: 9 0 9 0 7 , it means that you have successfully started the NMS server. And then you can  close the NMS Server window, the server is still running i n the background.

FS M6200 Series WDM Network - fig 29

Step 5: Open a browser window. (Recommend IE11.0 and above version or Google Chrome browser).

  1. If you log in from local NMS host, enter localhost:9090 in the address bar to open the login interface.
  2. If you log in from other remote host, enter the server IP address XXX.XXX.XXX.XXX:9090 {IP address of NMS server) to open the login interface.

Step 6: Enter correct user name and password (For the administrator, the default login user name is “root’, and the default password is “public”), as shown in the figure below:

FS M6200 Series WDM Network - fig 30

Step 7: Click login, you are now ready to configure M series platform
NOTE: Refer to the M SERIES NETWORK MANAGEMNT USER MANUAL online for further information

Troubleshooting

Module LEDs Working Abnormally

  1. Check the power cable connections at the M6200 series managed chassis and the power source.
  2. Make sure that all cables are used correctly and comply with the power specifications.
  3. Make sure that business modules are in the right position in the M6200 series managed chassis.

Accessing the Web-based Configuration Page Unsuccessfully

  1. Check MGMT ports LED on the NMU module and make sure the Ethernet cable is connected properly.
  2. Try another port on the NMU module and make sure the Ethernet cable is suitable and works normally.
  3. Power off the M6200 series managed chassis. After a while, power it on again.
  4. Make sure the IP address of your NMS server is correctly configured.
  5. If you still cannot access the configuration page, please reinitialize NMS server to its factory defaults.

Business Module Cannot Be Added

  1. Enter through CMD.
  2. Ping business module IP to check whether it can communicate.
  3. Check whether normal communication can be made between business module and NMU module.
  4. Change another business module.

Online Resources

Product Warranty

FS ensures our customers that any damage or faulty items due to our workmanship, we will offer a free return within 30 Days from the day you receive your goods. This excludes any custom made items or tailored solutions.
 Warranty: M6200 series enjoy 2 years limited warranty against defect In materials or workmanship. For more details about warranty, please check at : https://www.fs.com/policies/warranty.html
Return: If you want to return item(s), information on how to return can be found at: https://www.fs.com/policies/day_return_policy.html

Compliance Information

FCC
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This  equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a  particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following  measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. this device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation,

CAUTION:
Any changes or modifications not expressly approved by the grantee of this device could void the user’s authority to operate the equipment.

Responsible party (only for FCC matter)
FS.COM Inc.
380 CenterPoint Blvd, New Castle, DE 19720, United States https://www.fs.com

CE
FS.COM GmbH hereby declares that this device is in compliance with the Directive 2014/30/EU. A copy of the EU Declaration of Conformity is available at www.fs.com/company/quality_control.html
Die FS.COM GmbH erklart hermit, dads dieses Great met der Richtlinie 2014/30/EU conform ist. Eine
Kopy der EU-Konformitatserklarung fined Sie under www.fs.com/de/company/quality_control.html
FS.COM GmbH declarer par la presented que cat apparel Est conformed a la Directive 2014/30/UE. Une copied de la Declaration UE de Conformity Est disponible sur https://www.fs.com/fr/company/quality_control.html

FS.COM LIMITED
24F, Infor Center, No.19, Haitian 2nd Rd,
Beihai Community, Yehia Street, Nanshan
District, Shenzhen City

FS.COM GmbH
NOVA Gewerbepark Building 7, Am
Gild 7, 85375 Neufahrn bee Munich, Germany

References