OttLite SCEQB00Z-CA LED Sanitizing Lamp with Wireless Charging User Manual
- June 6, 2024
- OttLite
Table of Contents
- OttLite SCEQB00Z-CA LED Sanitizing Lamp with Wireless Charging
- TOUCH KEY PANEL INSTRUCTIONS
- CALENDAR AND CLOCK SETTING
- ALARM & SNOOZE FUNCTION SETTING
- TEMPERATURE SWITCH SETTING
- CONTROL PANEL (Q) icon legend
- WIRELESS CHARGING INSTRUCTIONS
- BATTERY REPLACEMENT
- FCC PART 15
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
OttLite SCEQB00Z-CA LED Sanitizing Lamp with Wireless Charging
CAUTION!
Battery Safety: This product contains a button battery. If swallowed, it could
cause severe injury or death in just 2 hours. Seek medical attention
immediately.
SEE ADDITIONAL SAFETY WARNING.
CONGRATULATIONS!
You’ve purchased the finest in natural lighting technology with your new
OttLite® product.
WARNING: To prevent electric shock, make sure the lamp is not plugged in
until all steps are complete.
NOTE: THIS UNIT IS FULLY ASSEMBLED
- Remove lamp from packing, placing lamp body base (A) flat on a steady surface.
- Connect power adapter input (H) into connector (J) in the rear-bottom of the lamp.
- Plug the power adapter (G) into a standard household 120V AC outlet. Note: Only use with the supplied power adapter to avoid damage or fire.
- Turn the lamp ON & OFF using power switch in touch panel (B) located on top of base (A).
- Touch panel (B) includes multiple “touch” keys that control the lamp’s mode and brightness within each mode. This lamp provides five levels of brightness. See Touch Key Panel Instructions section for operating instructions.
- Control panel (Q) is used to set the lamp’s calendar, alarm setting and display screen light. See Calendar and Clock Setting section for operating instructions.
- Wireless charger for Qi-certified devices (F) is located in the center of the base (A). See Wireless Charging Instructions section for details.
- To reposition the light, hold base (A) steady and grasp either lamp body (C) or shade (D) depending on needed adjustment
- Refer to Diagrams 1 and 2 for lamp maximum adjustment range.
NOTE: DO NOT FORCE the shade or lamp body outside allowable adjustable range as excessive adjustment may cause damage.
TOUCH KEY PANEL INSTRUCTIONS
To power lamp and operate LED settings, slightly touch required “key” to achieve the following:
-
• Turn lamp “ON/OFF”: touch POWER BUTTON key as needed.
• To adjust brightness: touch OR key as needed. -
Touch and hold M key to change modes. The three modes are; ClearSun LED, Sanitizing, and ClearSun + Sanitizing. ClearSun + Sanitizing mode utilizes both the Clearsun LEDs and Sanitizing LEDs simultaneously to provide continuous cleaning
NOTE: The active mode will be indicated by the lights (N and P) next to the icons. If indicator light (N) is illuminated, ClearSun mode is on. If indicator light (P) is illuminated, Sanitizing mode is on. If both indicator lights (N and P) are illuminated, Clearsun + Sanitize mode is on.
CALENDAR AND CLOCK SETTING
ALARM & SNOOZE FUNCTION SETTING
TEMPERATURE SWITCH SETTING
- In normal mode, touch (down) key to switch between ºF and ºC display.
- To adjust display screen brightness, touch to choose suitable brightness setting.
NOTE: Display screen defaults to “highest” brightness setting when power initially applied.
CONTROL PANEL (Q) icon legend
(setting) button – to set calendar; in alarm mode, push key to turn off alarm.
M (mode) button – push to set alarm and snooze
(up) button – In setting mode, push to increase.
(down) button – In setting mode, push to decrease.
Push display key for suitable brightness.
WIRELESS CHARGING INSTRUCTIONS
Wireless charging requires a Qi-certified device. To determine if your device
is Qi-certified, please visit the Wireless Power Consortium website.
To wirelessly charge a device, perform the following:
- Place the device, which supports Qi wireless charging standard, face up on the middle of the Qi wireless charging icon (F).
- When the device is centered on the Qi wireless charging icon (F), a solid RED light (E) will indicate the device is charging properly. NOTE: If RED light is blinking, this indicates the device is not charging and needs to be properly centered.
- Check the charge level on your device periodically to determine when device is fully charged. NOTE: Product DOES NOT provide any indication of when device is fully charged.
CAUTION! DEVICE MAY BECOME WARM DURING CHARGING. THIS IS NORMAL AND PART
OF THE PROCESS. CHARGING TIMES VARY BY DEVICE
SAFETY WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO
PERSONS
- Turn lamp off and WAIT UNTIL LAMP HEAD (D) AND ADAPTER (G) ARE COOL before handling.
- The LED panel (L) located in shade (D) might get hot after several hours of continuous use DO NOT place your hands directly on LED light panel.
- Never use with an extension cord unless the plug can be fully inserted into the receptacles in the extension cord.
- Do not alter the plug.
- The lamp head included with this unit cannot be replaced by the consumer.
- INDOOR USE ONLY
NOTE: The important safety instructions appearing in this instruction sheet are not meant to cover all possible conditions and situations that may occur. It must be understood that common sense, caution, and care must be used with any electrical product.
BATTERY REPLACEMENT
-
This lamp uses a CR2032 battery. For battery replacement see diagram 3.
Battery compartment is located on the backside of lamp body (C). -
To remove/install button cell battery: remove battery compartment door located in the lower half of body section (C) on back-side of lamp. To remove battery compartment door turn screw counter-clockwise.
-
Button cell battery is to be installed with the “+” or flat side facing upward.
-
Attach battery compartment door when finished and re-insert screw.
NOTE: DO NOT over-tighten screw to avoid it being stripped.
SAFETY WARNING:
- CAUTION: DO NOT INGEST BATTERY; CHEMICAL BURN HAZARD!
- This lamp contains a coin/button cell battery. If the coin/button cell battery is swallowed, it can cause severe internal burns in just two hours and can lead to death.
- Keep new and used batteries away from children.
- If the battery compartment does not close securely, stop using the product and keep it away from children.
- If you think batteries might have been swallowed or placed inside any part of the body, seek immediate medical attention.
NOTE: Coin/button cell batteries are small, single cell devices having a diameter greater than their height.
CAUTION! IF THE EXTERNAL FLEXIBLE CABLE OR CORD OF THIS LUMINAIRE IS DAMAGED, IT SHALL BE EXCLUSIVELY REPLACED BY THE MANUFACTURER OR ITS SERVICE AGENT OR A SIMILAR QUALIFIED PERSON IN ORDER TO AVOID A HAZARD. INDOOR USE ONLY.
CAUTION! THE LIGHT SOURCE OF THIS LUMINAIRE IS NOT REPLACEABLE; WHEN
THE LIGHT SOURCE REACHES ITS END OF LIFE THE WHOLE LUMINAIRE SHALL BE
REPLACED.
FCC PART 15
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that the interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected .
- Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions:
- this device may not cause harmful interference, and
- this device must accept any interference received, including interference that may cause undesired operation.
To maintain compliance with the RF exposure guidelines, place the product at
least 20cm from nearby persons.
IC CANADA
This device contains licence-exempt transmitter(s)/receiver that comply with
Innovation, Science and Economic Development Canada’s licence-exempt RSS(s).
Operation is subject to the following two conditions:
- This device may not cause interference.
- This device must accept any interference, including interference that may cause undesired operation of the device.
CAN RSS-216/CNR-216
CAN ICES-005 (B)/NMB-005 (B)
CAUTION: Any change or modification to product not expressly recognized
by OttLite Technologies voids OttLite’s responsibility for proper function of
product.
POWER ADAPTER SPECIFICATION:
Input: AC 100-240V, 50/60 Hz, 1.0A
Output: 12V DC, 2.5A with a Male DC Plug Qi CHARGER SPECIFICATION:
Output: up to 5 Watts depending on device
EPA EST. No 98777-FL-1
THIS LAMP CONTAINS a 5V, 2,1A USB output port (K) located on the bottom rear
of lamp. USB port can charge items such as tablets, cellular phones, etc.
The “Qi” symbol is a trademark of the Wireless Power Consortium
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>