MRT-3.1 Universal Electronic Week Temperature Controller
“`html
Specifications
-
Symbol: …MRT-3.1, …MRT-3.2
-
Supply Voltage: 230 V AC 50 Hz (195-253
V) -
Temperature Setting Range: Adjustable
-
Relay Output: 230 V, 10mA… 16(4)A*
-
Output Signal: PWM or ON/OFF pulse width
modulation -
PWM Time Intervals: Adjustable
-
Hysteresis: Adjustable
-
Pow er Consumption: ~ 1.2 W
-
Accuracy of the Clock: < 4 minutes per
year -
Memory Battery Life: ~ 10 years
-
Ambient Temperature: Operating and storing
conditions specified -
Dimensions: 80 x 80 x 44.00 mm
-
Battery: CR 2032 included
-
Installation Recommendations:
-
Install in a place with easy access and free air
circulation. -
Avoid direct sunlight, drafts, and other heat/cold
sources. -
Avoid locations on outside walls or below 1.5 m height.
Product Usage Instructions
Programming the Universal Electronic Week Temperature
Controller
-
Ensure the controller is properly connected to the power
supply. -
Select the desired mode: FLOOR, ROOM, or LIMITER.
-
Program up to 9 time intervals per day along with temperature
settings. -
Adjust PWM time intervals and hysteresis as needed.
Battery Replacement
If the controller’s battery is depleted, follow these steps:
- Locate the CR 2032 battery compartment on the controller.
- Replace the battery with a new CR 2032 battery.
- Reprogram any settings that may have been lost due to battery
depletion.
Frequently Asked Questions (FAQ)
Q: What should I do if the heating/cooling symbol flashes on
the controller?
A: The flashing symbol indicates improper connection or
de-energization. Check the connections and power supply to resolve
the issue.
Q: How can I extend the probe length for temperature
sensing?
A: An optional SO-1 probe with a length of 4m can be extended up
to 50m for temperature sensing. Connect the additional probe as
needed.
Q: What is the warranty period for the universal electronic
week temperature controller?
A: The warranty period is 12 months from the date of purchase.
Ensure to retain proof of purchase for warranty claims.
“`
USER’S MANUAL – UNIVERSAL ELECTRONIC WEEK TEMPERATURE CONTROLLER
Characteristics of the universal electronic week temperature controller The
universal electronic week temperature controller allows you to program up to 9
time intervals per day and the temperature according to your preferences. The
temperature controller allows operation in the following three modes: – FLOOR
– control of underfloor heating, – ROOM – control of room temperature, –
LIMITER – room temperature controller with limiter.
53,90
53,90
44,00
number of the current day of the week indication of the current room
temperature heating/cooling symbol (flashes if the controller module is not
properly connected or is de-energized) indication of the current time
operation mode (AUTO)
Warranty terms The warranty is provided for a period of 12 months from the
date of purchase. The defective controller, together with the proof of
purchase, shall be delivered to the manufacturer or to the dealer. The
warranty does not cover fuse replacement, mechanical damage, defects resulting
from self-repair and improper use of the product. The warranty period is
extended by the duration of the repair.
Notice! Protection class of the shield The installation must be carried out by
a qualified person at de-energized voltage and must comply with national
safety standards. In order to maintain Class II protection, the user must be
prevented from accessing the rear parts of the installation. The mechanism is
designed to adjust the temperature only in dry rooms under standard ambient
conditions. The controller meets the requirements of EN 60730. It is an
“independently installed device” operating according to the way 1C works.
Karlik Elektrotechnik Sp. z o.o. | ul. Wrzesiska 29 | 62-330 Nekla | tel. +48
61 437 34 00 | e-mail: karlik@karlik.pl | www.karlik.pl 1 I 19
Technical data
Symbol
…MRT-3.1, …MRT-3.2
Supply v oltage
230 V AC 50 Hz (195-253 V)
Temperature setting range
5 °C-30 °C; at interv als of 0.5 °C
Temperature control at interv als of
0,1 °C
Relay
output, 230 V
Connection current
10mA… 16(4)A*; 230 V~
Output signal
PWM or ON/OFF pulse w idth modulation
PWM time interv als
adjustable
Hysteresis
adjustable
Shortest time interv al: 10 minutes
10 minutes
Pow er consumption
~ 1,2 W
Accuracy of the clock
< 4 minutes / year
Memory maintaining by battery
~ 10 years
Probe (optional)
SO-1, length 4 m, can be extended to 50 m
Ambient temperature:
– w hen operating
0°C – 40°C (w ithout humidity)
– w hen storing
20 °C – 70 °C (w ithout humidity)
Rated surge v oltage
4 kV
Testing temperature of the head
115 °C
Voltage and current for interference measurements
230 V, 0,1A
Protection grade
I P 30
Shield protection class
I I (see: “Warning! Protection class of the shield”)
Softw are class
A
Degree of contamination
2
Dimensions w ith outer frame
80 x 80 x 44,00 mm
*under current > 14A, N – wire must not be connected to the controller, only directly connected
Battery A CR 2032 battery is included with the temperature controller, which allows the controller to be programmed without being plugged in. If the battery is depleted and the controller is unplugged, the settings of the controller return to the factory settings. According to EU Directive 2006/66/EC, the battery may only be removed at the end of its life by a qualified person.
Installation of the universal electronic week temperature controller The controller is recommended to be installed in a place that: – has easy access, – is free of curtains, shelves cabinets, etc., – allows free air circulation, – is not exposed to direct sunlight, – is not exposed to drafts (with open doors and windows), – is not exposed to any other source of heat/cold, – is not located on an outside wall, – is at a height of 1.5 m above the floor.
Notice! – universal electronic week temperature controller should be mounted in a flush-mounted box with a diameter of Ø60, made of plastic, – the maximum length of the cable insulation removed must not exceed 8 mm, – for cables with a cross-section of 1-2.5 mm2, – the connection should be made in accordance with the diagram on page 3.
Karlik Elektrotechnik Sp. z o.o. | ul. Wrzesiska 29 | 62-330 Nekla | tel. +48 61 437 34 00 | e-mail: karlik@karlik.pl | www.karlik.pl 2 I 19
Wiring diagram
230V~ 50Hz
Load
Notice! The plastic tab should be installed in such a way as to provide insulation between the connections/wires and the mounting screws.
SO-1
Probe SO-1 (accessory) To insert or remove the flexible probe cable, press the
white buttons under the cable.
Ø7,8
20,00
Probe resistance values (SO-1)
Temperature 10 0C 20 0C 25 0C 30 0C 40 0C 50 0C
Resistance 66,8 k 41,3 k 33,0 k 26,3 k 17,0 k 11,3 k
Universal electronic week temperature controller – components
controller display (control unit)
MINI-series intermediate frame
MINI-series external frame
controller module
Karlik Elektrotechnik Sp. z o.o. | ul. Wrzesiska 29 | 62-330 Nekla | tel. +48 61 437 34 00 | e-mail: karlik@karlik.pl | www.karlik.pl 3 I 19
Operating mode selection The universal electronic week temperature controller
allows operation in the following three operating modes: – ROOM – room
temperature control, – FLOOR – underfloor heating control, – LIMITER – room
temperature controller with limiter.
To select the appropriate mode: 1. Press the MENU button, then use the +/-
buttons to move to the INSTALLERSETTING CHANGE APPLICATION DETAILS (confirm
the selection with the OK button). 2. Using the +/- buttons, select code 7. 3.
Select H1 – APPLICATION (the selection should be confirmed with the OK.
button), using the +/buttons, switch to the preferred mode of the ROOM, FLOOR
or LIMITER (the selection should be confirmed with the OK button). 4.
Depending on the mode selection, further steps should be carried out according
to the instructions: – ROOM – page 6, – FLOOR – page 9, – LIMITER – page 12, –
functions and operation of the temperature controller for all modes (ROOM,
FLOOR, LIMITER) – page 15.
Notice! If the mode is changed, the user and installer settings change to the
default values.
Properties of the temperature controller (depending on the selected mode of
operation): – line text display for easy operation, – display backlight
(…MRT-3.1 white, …MRT-3.1 blue), – current time (setting year, month, day,
time), – automatic switching of daylight saving time, – max. 9 time intervals
per day (separate during the entire day), – default and customized time
programs, – optimal start (temperature will reach the set value), –
programmable also when the control unit (display) is detached, – shutdown
function, MENU button must be held for 10 seconds, – vacation function with
date setting (you can set the date from…to), – energy consumption display (ON
time * cost) for the last 2 days, week, 30 days, year, – option to set energy
cost after 1 hour, – anti-frost protection, – temperature can be set only
within a limited range, – access protection (unwanted override), – operating
language selection, – PWM or ON/OFF control mode, – minimum values of ON/OFF
time and hysteresis set for ON/OFF control, – possibility to set min. and max.
floor temperature (applies to LIMITER mode), – valve protection (applies to
ROOM and LIMITER modes), – adaptability to set valves in open or closed
position (applies to ROOM and LIMITER modes), – selectable heating or cooling
function (applies to ROOM mode), – measurement of room temperature by remote
sensor (probe) or internal sensor (applies to ROOM mode), – clock (Party) –
specified temperature in a set time interval (applies to ROOM and FLOOR
modes), – floor temperature presented numerically (applies to FLOOR mode).
Karlik Elektrotechnik Sp. z o.o. | ul. Wrzesiska 29 | 62-330 Nekla | tel. +48
61 437 34 00 | e-mail: karlik@karlik.pl | www.karlik.pl 4 I 19
PROGRAMMING MANUAL – UNIVERSAL ELECTRONIC WEEK TEMPERATURE CONTROLLER – ROOM
Characteristics of the universal electronic week temperature controller – room After proper installation and connection, the temperature controller automatically shows the time of day and room temperature. In AUTO operation mode, heating (cooling) will be automatically turned on, according to the programmed time and temperature. Program 1 is the program set by default. The room temperature is adjusted based on the temperature measurement taken by the internal sensor. The heating will turn on as the temperature drops below the level of the setpoint.
The week room temperature controller can be used to control the room temperature in combination with : – thermal actuators, such as underfloor water heating or convector heaters, – oil or gas radiators, – circulation pumps, – heat pumps, – electric convector heaters, ceiling heating and storage heating.
Connecting a probe (SO-1) To measure the room temperature, instead of an internal sensor, you can use a probe (SO-1). Probe selection can be made in the menu, see H1. The probe should be placed in the electrical conduit (which will facilitate replacement if necessary). The probe can be extended using cables or connections for 230V to a maximum. 50 m. Avoid running the probe cables parallel to the power cables, such as in the cable duct.
Notice! The probe wire may be under mains voltage.
Defined programs The temperature controller has three defined programs for temperature control at specific time intervals. at the user’s disposal. Program 1 is specified as standard. To select another program (see G1).
Program 1
Time allocation Time Temperature 0C
1 06:00
21
Monday to Friday
2 08:30
18
3 12:00
21
4 14:00
18
5 17:00
21
6 22:00
15
Time allocation Time Temperature 0C
1 07:00
21
*23:00/22:00 = 23:00 on Saturday
Saturday and Sunday
2 10:00
18
3 12:00
21
4 14:00
21
5 17:00
21
6 23:00/22:00*
15
Karlik Elektrotechnik Sp. z o.o. | ul. Wrzesiska 29 | 62-330 Nekla | tel. +48 61 437 34 00 | e-mail: karlik@karlik.pl | www.karlik.pl 5 I 19
Monday – Friday Saturday – Sunday
Program 2
Time allocation Time Temperature 0C
1 06:00
21
Time allocation Time Temperature 0C
1 07:00
21
*23:00/22:00 = 23:00 on Saturday
Monday to Friday
2 08:30
18
3 12:00
21
4 14:00
18
Saturday and Sunday
5 17:00
21
6 22:00
15
2 23:00/22:00*
15
Monday – Friday Saturday – Sunday
Karlik Elektrotechnik Sp. z o.o. | ul. Wrzesiska 29 | 62-330 Nekla | tel. +48
61 437 34 00 | e-mail: karlik@karlik.pl | www.karlik.pl 6 I 19
Program 3
Time allocation Time Temperature 0C
1 06:00
21
Time allocation Time Temperature 0C
1 07:00
21
*23:00/22:00 = 23:00 on Saturday
Monday to Friday
2 08:30
18
Saturday and Sunday
2 10:00
18
3 17:00
21
4 22:00
15
3 12:00
21
4 23:00/22:00*
15
Monday – Friday
Saturday – Sunday
Notes on programming – active settings automatically turn off without saving,
three minutes after the last press. This will be followed by a return to the
previous active mode, e.g. AUTO, MAN, etc. – programming: set the value with
the +/- buttons, and then press OK. – in case of settings for the user and
installer, the menu displays the numbers of the items listed in the manual,
e.g., G1 for “program selection” or H2 for “control mode.”
Troubleshooting 1. It’s getting warm too late: – has the time interval and
time been set correctly? – is “optimal start” enabled? (See H7) – did the
controller have enough (a few days) to adapt to the characteristics of the
room? – is the automatic daylight saving time change function enabled?(see G5)
2. The controller does not accept any changes. – has access protection been
activated? (see G6) 3. The temperature setting range is limited. – are
temperature restrictions enabled? (see G7) 4. The temperature display does not
change: – is the display of the required target temperature activated? (see
G10)
Karlik Elektrotechnik Sp. z o.o. | ul. Wrzesiska 29 | 62-330 Nekla | tel. +48
61 437 34 00 | e-mail: karlik@karlik.pl | www.karlik.pl 7 I 19
PROGRAMMING MANUAL – UNIVERSAL ELECTRONIC WEEK TEMPERATURE CONTROLLER – FLOOR
Characteristics of the universal electronic week temperature controller – floor After proper installation and connection, the temperature controller automatically shows the time of day and room temperature. In AUTO operation mode, the heating will be automatically turned on, according to the programmed time and temperature. Program 1 is the default setting, the temperature is adjusted based on the floor temperature, and the heating will turn on automatically when the floor temperature drops below the level set on the thermostat and turn off when the specified temperature is reached.
The week temperature controller for underfloor heating can be used to control the temperature in combination with : – direct heating, – underfloor heating system.
Connecting the probe (SO-1) The probe should be placed in the electrical conduit (which will facilitate replacement if necessary). The probe can be extended using cables or connections for 230V to a maximum. 50 m. Avoid running the probe cables parallel to the power cables, such as in the cable duct.
Notice! The probe wire may be under mains voltage.
Defined programs The temperature controller has three defined programs for temperature control at specific time intervals. at the user’s disposal. Program 1 is specified as standard. To select another program (see G1).
Program 1
Monday to Friday
Time allocation Time Temperature 0C
1 06:00
28
2 08:00
18
3 19:00
28
4 22:00
15
Time allocation Time Temperature 0C
1 08:00
28
Saturday and Sunday
2 10:00
18
3 19:00
28
4 22:00
15
Karlik Elektrotechnik Sp. z o.o. | ul. Wrzesiska 29 | 62-330 Nekla | tel. +48 61 437 34 00 | e-mail: karlik@karlik.pl | www.karlik.pl 8 I 19
oC 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14
6:00 h
8:00 h
Monday – Friday Saturday – Sunday
10:00 h 12:00 h 14:00 h 16:00 h 18:00 h 20:00 h 22:00 h
Program 2
Monday to Friday
Time allocation Time Temperature 0C
1 06:00
28
2 08:00
18
3 12:00
28
4 14:00
18
5 19:00
28
6 22:00
15
Time allocation Time Temperature 0C
1 08:00
28
Saturday and Sunday
2 10:00
18
3 12:00
28
4 14:00
18
5 19:00
28
6 22:00
15
oC 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14
6:00 h
8:00 h
Monday – Friday Saturday – Sunday
10:00 h 12:00 h 14:00 h 16:00 h 18:00 h 20:00 h 22:00 h
Karlik Elektrotechnik Sp. z o.o. | ul. Wrzesiska 29 | 62-330 Nekla | tel. +48 61 437 34 00 | e-mail: karlik@karlik.pl | www.karlik.pl 9 I 19
Program 3
Time allocation Time Temperature 0C
1 11:00
28
Monday to Friday
2 13:00
18
3 22:00
15
Saturday and Sunday
Time allocation Time Temperature 0C
1 08:00
28
*23:00/22:00 = 23:00 on Saturday
2 10:00
18
3 19:00
28
4 22:00
15
oC
28
27
26
25
24
23
22
21
20
19
18
17
16
Monday – Friday
15
Saturday – Sunday
14
6:00 h 8:00 h 10:00 h 12:00 h 14:00 h 16:00 h 18:00 h 20:00 h 22:00 h
Notes on programming – active settings automatically turn off without saving,
three minutes after the last press. This will be followed by a return to the
previous active mode, e.g. AUTO, MAN, etc. – programming: set the value with
the +/- buttons, and then press OK. – in case of settings for the user and
installer, the menu displays the numbers of the items listed in the manual,
e.g., G1 for “program selection” or H2 for “control mode”.
Troubleshooting 1. It’s getting warm too late: – has the time interval and time been set correctly? – is “optimal start” enabled? (See H7) – did the controller have enough (a few days) to adapt to the characteristics of the room? – is the date set correctly? – is the automatic daylight saving time change function enabled?(see G5) 2. The controller does not accept any changes. – has access protection been activated? (see G6) 3. The temperature setting range is limited. – are temperature restrictions enabled? (see G7) 4. The temperature display does not change: – is the display of the required target temperature activated? (see G10)
Karlik Elektrotechnik Sp. z o.o. | ul. Wrzesiska 29 | 62-330 Nekla | tel. +48 61 437 34 00 | e-mail: karlik@karlik.pl | www.karlik.pl 10 I 19
PROGRAMMING MANUAL – UNIVERSAL ELECTRONIC WEEK TEMPERATURE CONTROLLER – LIMITER
Characteristics of the universal electronic week temperature controller – limiter After proper installation and connection, the temperature controller automatically shows the time of day and room temperature. In AUTO operation mode, the heating will be automatically turned on, according to the programmed time and temperature. Program 1 is the program set by default. The room temperature will be adjusted and the floor temperature will be limited (measured by the remote sensor). The heating will turn on automatically as the temperature drops below the setpoint. In the case of the “Minimum floor temperature” function, the heating will turn on if the floor temperature falls below the set minimum value. This is the case even when the room temperature is too high. In the case of the “Maximum floor temperature” function, the heating will turn off if the floor temperature exceeds the set maximum value. This is the case even when the room temperature is too low. The week temperature controller for underfloor heating can be used to control the temperature in combination with : – electric floor heating systems, where the floor temperature must be within a certain range of values, – hot water-fed floor heating systems in combination with thermal actuators.
Probe connection (SO-1) When using the “LIMITER” mode of operation, the temperature controller requires using a probe (SO-1). The probe should be placed in the electrical conduit (which will facilitate replacement if necessary). The probe can be extended using cables or connections for 230V to a maximum. 50 m. Avoid running the probe cables parallel to the power cables, such as in the cable duct.
Notice! The probe wire may be under mains voltage.
Defined programs The temperature controller has three defined programs for temperature control at specific time intervals. at the user’s disposal. Program 1 is specified as standard. To select another program (see G1).
Program 1
Time allocation Time Temperature 0C
1 06:00
21
Monday to Friday
2 08:30
18
3 12:00
21
4 14:00
18
5 17:00
21
6 22:00
15
Time allocation Time Temperature 0C
1 07:00
21
*23:00/22:00 = 23:00 on Saturday
Saturday and Sunday
2 10:00
18
3 12:00
21
4 14:00
21
5 17:00
21
6 22:00/23:00*
15
Karlik Elektrotechnik Sp. z o.o. | ul. Wrzesiska 29 | 62-330 Nekla | tel. +48 61 437 34 00 | e-mail: karlik@karlik.pl | www.karlik.pl 11 I 19
Monday – Friday Saturday – Sunday
Program 2
Time allocation Time Temperature 0C
1 06:00
21
Time allocation Time Temperature 0C
1 07:00
21
*23:00/22:00 = 23:00 on Saturday
Monday to Friday
2 08:30
18
3 12:00
21
4 14:00
18
Saturday and Sunday
5 17:00
21
6 22:00
15
2 23:00/22:00*
15
Monday – Friday Saturday – Sunday
Karlik Elektrotechnik Sp. z o.o. | ul. Wrzesiska 29 | 62-330 Nekla | tel. +48
61 437 34 00 | e-mail: karlik@karlik.pl | www.karlik.pl 12 I 19
Program 3
Time allocation Time Temperature 0C
1 06:00
21
Przydzial czasowy
1
Czas Temperature 0C
07:00 21
*23:00/22:00 = 23:00 on Saturday
Monday to Friday 2 08:30 18
Saturday and Sunday 2 10:00 18
3 17:00
21
4 22:00
15
3 12:00
21
4 23:00/22:00*
15
Monday – Friday
Saturday – Sunday
Notes on programming – active settings automatically turn off without saving,
three minutes after the last press. This will be followed by a return to the
previous active mode, e.g. AUTO, MAN, etc. – programming: set the value with
the +/- buttons, and then press OK. – in case of settings for the user and
installer, the menu displays the numbers of the items listed in the manual,
e.g., G1 for “program selection” or H2 for “control mode.”
Troubleshooting 1. It’s getting warm too late: – has the time interval and
time been set correctly? – is “optimal start” enabled? (See H7) – did the
controller have enough (a few days) to adapt to the characteristics of the
room? – is the automatic daylight saving time change function enabled?(see G5)
2. The controller does not accept any changes. – has access protection been
activated? (see G6) 3. The temperature setting range is limited. – are
temperature restrictions enabled? (see G7) 4. The temperature display does not
change: – is the display of the required target temperature activated? (see
G10) 5 The room heats up too slowly – the floor temperature can be limited by
the “Maximum floor temperature” function of the controller. (See H) 6. The
room heats up too quickly – the floor temperature can be limited by the
“Minimum floor temperature” function of the controller. (see H)
Karlik Elektrotechnik Sp. z o.o. | ul. Wrzesiska 29 | 62-330 Nekla | tel. +48
61 437 34 00 | e-mail: karlik@karlik.pl | www.karlik.pl 13 I 19
DESCRIPTION OF FUNCTIONS AND OPERATION OF THE UNIVERSAL ELECTRONIC WEEK TEMPERATURE CONTROLLER – FLOOR, ROOM, LIMITER
Language selection For products that do not have a defined language, the user must set their language by pressing: ENGLISH +/- to select the language and then OK to confirm the selection, the screen will display AUTO mode (to change the language back, select G14 in the MENU). The foregoing settings are only required to be entered when the device is first started or restarted.
How to use the temperature controller? – changing the temperature (until the next time interval), see: buttons, +/- in AUTO – temperature control according to specific properties, see: main menu, AUTO – fixed temperature setting (manual operation = MAN), see: main menu, MAN – temperature setting for a specific number of hours, see: main menu, TIMER – temperature setting for a specific day, see: main menu, HOLIDAY – setting a separate program for specific days, see: main menu, AT HOME – TEMP FOR EXTRA DAYS – adjusting the controller to personal needs, see: main menu, USER – SETTING CHANGE BEHAVIOUR – adjust the controller to the needs of the application, see: main menu, INSTALLER – SETTING CHANGE APPLICATION DETAILS
Buttons
Buttons
Function
To confirm / activate
Periodically change the temperature to the next time
interv al, displaying OK as minus AUTO (AUTO-).
+/- in AUTO (-)
The first time you press it, the set temperature will be
OK
displayed, and after pressing it again, its v alue will
change with ev ery press
+/- in MENU
Go +/- in MENU
OK
Press to confirm your setting/selection
INFO
Additional information in AUTO, MAN, TI MER, HOME is displayed. To cancel, press the button again
MENU
Enter MENU, use +/- buttons to mov e next
MENU
One step back (undo)
MENU for 10 seconds Turning the heating off. OFF will be displayed later, see G4.
Karlik Elektrotechnik Sp. z o.o. | ul. Wrzesiska 29 | 62-330 Nekla | tel. +48 61 437 34 00 | e-mail: karlik@karlik.pl | www.karlik.pl 14 I 19
Main menu A MENU B AUTO
C MAN
D TIMER
E HOLIDAY
AT HOME F (temperature on
additional days)
USER G (adjusting the
operation mode)
INSTALLER H (changing the
operation mode)
To confirm / activate
Use the +/- buttons to mov e to the desired menu item.
The temperature w ill automatically set according to the
time and temperature of the current program, see G1. Use the +/- buttons to change the temperature v alues
up
OK
to the next time interv al.
The temperature w ill be constantly monitored, to set it,
use the +/- buttons and confirm the changes w ith the
OK
button.
The temperature w ill be controlled temporarily according to the time and temperature settings in the menu. After OK this time, the prev ious mode of operation w ill be restored.
Allow s you to set both the temperature and the number
of days before the initial v alue is restored. The HOLI DAY
mode turns on at 0:00 on the first day and turns off at 24:00
on the last day. The AUTO function is activ e before the
HOLI DAY mode is activ ated. While w aiting for the
v acation start date, you can select other modes of operation (AUTO, MAN, TI MER, AT HOME). The I NFO
OK
function w ill prov ide detailed information about the
upcoming v acation. I n this situation, the HOLI DAY mode
w ill start automatically w hen the start date occurs. After
the v acation period, the prev ious mode of operation w ill
be restored.
The temperature w ill set after this set program (regardless
of AUTO). The temperature w ill apply on all days. The
primary settings correspond to the program starting from Monday. The user closes the program by selecting, e.g.
OK
AU TO.
Usage: time off, v acation, illness, etc.
Adaptation to the user’s lifestyle.
OK
Adjust the temperature settings to the heating system (function av ailable for installers only).
OK
Karlik Elektrotechnik Sp. z o.o. | ul. Wrzesiska 29 | 62-330 Nekla | tel. +48 61 437 34 00 | e-mail: karlik@karlik.pl | www.karlik.pl 15 I 19
Se ngs:
G
USER CHANGE BEHAVIOR
Customiza on to meet the personal needs of the user
Default se ngs 0 = value range
ROOM
FLOOR
LIMITER
1
Program selec on
Selec ng a default program, see “Defined programs” (if another program is selected, the se ngs will not be saved).
P1 P1, P2, P3
P1
P1
P1, P2, P3 P1, P2, P3
2 Event se ng
Change the me and temperature on selected days of the ac ve program, see “Defined programs”. Each me interval can be reduced to the previous one or to 00:00. Each me interval can be extended un l 23:50, a er which ->>> will be displayed, indica ng that the me interval applies to the next day. If you press the +/- bu on during ->>>, you can set the me interval again. A total of as many as 9 me intervals can be set. The first digit indicates the current me interval, Yes, like the G1 such as 3. 12:00-14:00 means the third me interval. Time intervals can also be saved as me blocks selected by selec ng preset days (MondayFriday, Saturday/Sunday, MondaySunday). To finish programming, press the MENU bu on again. Selec ng a default program, see “Defined programs” (if another program is selected, the se ngs will not be saved).
Yes, like the G1 selected
Yes, like the G1 selected
3 Clock se ng
4
Off hea ng permenent
Se ng the current date and me.
The adjustment will be turned off, OFF will be displayed. The controller will
remain energized. An frost protec on can be triggered when ac vated, see H6.
Turning on again is possible by ac va ng AUTO mode or by pressing the MENU bu
on for 10 s. AUTO mode is ac vated when switching on NO again using the MENU
bu on or through the menu.
NO
NO
5
Summer / winter change
6 Key lock
7
Temp limit min / max temp
Selec ng automa c daylight saving me switching.
YES
Protec ng the controls against unauthorized use. Reac vated using the code = 93.
NO
Limits the temperature range that can be set by the user. Se ng is not possible if the two limits are iden cal. Affects the following modes: AUTO, MAN, VACATION, CLOCK, HOME, programming. The 5; 300C ac ve program/opera on mode will not be changed automa cally.
YES
YES
NO
NO
5; 300C 5; 300C
Karlik Elektrotechnik Sp. z o.o. | ul. Wrzesiska 29 | 62-330 Nekla | tel. +48 61 437 34 00 | e-mail: karlik@karlik.pl | www.karlik.pl
16 I 19
Se ngs:
G
USER CHANGE BEHAVIOR
Customiza on to meet the personal needs of the user
Default se ngs 0 = value range
ROOM
8
Cost / hr of energy
Displays the approximate energy cost per hour (pennies/hour), can be set. To use this func on as an hour meter, set a cost of 100 pennies/hour.
100 (1…999)
FLOOR
LIMITER
100
100
(1…999) (1…999)
Energy 9 consum on to
date
The approximate cost of energy in the controlled area will be displayed, for the last: 2 days, weeks, 30 days, a year. On the current day, the calcula on is performed in real me. When exceeded, 9999 will be displayed. This func on mainly applies to electric hea ng. Calcula on: heater opera ng me x energy cost per hour see above. For reset, see H9.
10 Set temp to read The required temperature will be displayed instead of the room temperature.
NO
NO
NO
11 Adjust temp
Set the temperature to the user’s personal requirements.
12
Number for floor temp
The floor temperature will be displayed as an ID number.
13 Blacklight
14 Language 15 Info
Reset user 16 se ngs only
Con nuous, off, or short when the bu on is pressed.
Language selec on. Display the type and version of the controller.
Only USER se ngs will be restored to the factory se ngs. The energy meter will
not be reset, in order to reset the meter, see H9.
0 (-5,0…+5,0)
NOT
0
APPLICABLE (-5,0…+5,0)
NOT APPLICABLE
NO
NOT APPLICABLE
SHORT (SHORT, OFF)
SHORT (SHORT, OFF)
SHORT (SHORT, OFF)
NO
NO
NO
Karlik Elektrotechnik Sp. z o.o. | ul. Wrzesiska 29 | 62-330 Nekla | tel. +48 61 437 34 00 | e-mail: karlik@karlik.pl | www.karlik.pl
17 I 19
Se ngs: INSTALLER H CHANGE APPLICATION 0 Code 1 Applica on
2 Control mode
Min/max floor 3 temp
4
Hea ng or cooling
5
Valve protec on
Adjust temperature se ngs to meet applica on requirements (only for installers)
Default se ngs 0 = value range
For these se ngs, enter a code (=7) that is valid for one hour.
ROOM
FLOOR
LIMITER
The controller is suitable for use in the hea ng system listed in the right column. You can choose whether to use the remote sensor.
ROOM
FLOOR
LIMITER
You can select the type of PWM or ON/OFF signal. For PWM, you can set the cycle me (in
PWN/10
minutes). Minimum ON/OFF me = 10% of cycle me. Use a short me for hea ng systems with fast (/10…30)
response mes, and a longer me for slow-response systems.
For ON/OFF, you can select:
– Hysteresis
OFF – no hysteresis se ng, even in the case of very small temperature changes, the relay will switch OFF (OFF,
for the me specified below.
0,1…5,0)
– Minimum ON/OFF me (the relay will be in ON or OFF mode at least for this me).
10min (1…30)
PWN/10 PWN/10 (/10…30) (/10…30)
OFF (OFF, OFF (OFF, 0,1…5,0) 0,1…5,0) 10min(1…30) 10min (1…30)
Limits the temperature of the floor. Possible selec on: – minimum floor temperature that does not drop below the set temperature (OFF = no limit); Mintemp. = 21°C, the floor temperature does not drop below 21°C, even if the room is too warm. – maximum floor temperature that does not rise above this set temperature (OFF = no limit); Maxtemp. = 35°C, the floor temperature does not exceed 35°C, even if the room is too cold. If one of these restric ons is not needed, set it to OFF.
NOT APPLICABLE
OFF (OFF, 10…Tmax) NOT APPLICABLE 35°C (OFF, Tmin…40)
HEATING: The controller operates in HEAT mode. REFRIGERATION: The controller
operates in COOLING mode. Condi ons: – cooling is only possible with the se ng
(H1) = ROOM, – an -frost protec on (H6) = NO (cannot be ac vated), – op mal
start (H7) = NO (cannot be ac vated), – in case of error = no cooling, – me
interval and temperature se ngs are the same as in HEAT mode (see G2), – only
for the ON/OFF control method.
The output relays will be ac vated at the specified me each day, at 10:00 am.
Hea ng (hea ng, cooling)
NOT
NOT
APPLICABLE APPLICABLE
3 min (OFF, 1…10)
NOT
3 min
APPLICABLE (OFF, 1…10)
Karlik Elektrotechnik Sp. z o.o. | ul. Wrzesiska 29 | 62-330 Nekla | tel. +48 61 437 34 00 | e-mail: karlik@karlik.pl | www.karlik.pl
18 I 19
Se ngs: INSTALLER H CHANGE APPLICATION
6 Frost protec on
7 Op mum start
8
Valves normally open
9
Energy counter reset
10
Floor temp display
Adjust temperature se ngs to meet applica on requirements (only for installers)
Default se ngs 0 = value range
ROOM
An -frost protec on limit temperature se ng. Turning on in the OFF mode, the temperature will be 50C
adjusted to this value.
(OFF, 5…30)
FLOOR
LIMITER
50C
50C
(OFF, 5…30) (OFF, 5…30)
The temperature will reach the setpoint at the me specified in the program. AUTO mode will be displayed in the previous compartment.
YES
NO
YES
If open valves must be normally used.
NO
NOT APPLICABLE
NO
The energy meter will be reset to 0.
NO
NO
NO
The temperature measured by the probe will be displayed (for service purposes).
NOT APPLICABLE
11 Reset all
All se ngs, both installer and user se ngs, will be restored to factory default.
Errors In this situation, “Err” will be flashing on the screen, possibly
indicating the following error: 1. CONFIGURATION – the display and module do
not match: – use only suitable parts, – turn the power off and on. 2.
COMMUNICATION – communication error between the display and the power module:
– remove the upper part and reconnect, – turn the power off and on. 3.
EXTERNAL SENSOR (PROBE) – remote sensor error – sensor replacement –
measurement span exceeded. In case of any of the foregoing errors, heating
will be on for 30% of the time.
In case of the ROOM mode of operation: if H4 = HEAT: heating will be on for
30% of the time, if H4 = COOL: no cooling.