Karlik IRO-2 Electronic Lighting Controller with Push and Rotary Button for LED Lamps User Manual

June 9, 2024
KarliK

USER MANUAL
ELECTRONIC LIGHTNING CONTROLLER
WITH PUSH AND ROTARY BUTTON FOR LED LAMPS

IRO-2 Electronic Lighting Controller with Push and Rotary Button for LED

Lamps

Characteristics of electronic lightning controller with push and rotary button for LED lamps Electronic lightning controller with push and rotary button (dimmer switch) ….IRO-2 enables adjustment of LED dimmable light, halogen light supplied by electronic transformer and i incandescent light.
Use of the controller increases comfort and daily savings in electricity which consumption is proportionate to the light intensity. Electronic lightning controller with push and rotary button… IRO-2 is an intelligent device, that can be programmed to be individually set according to minimal light level and operational mode.
Important!
Prior to the first start-up of the regulator, it is necessary to carry out its configuration (see programming instructions). With the configuration, the regulator “learns” how to cooperate with the lighting connected to it.
Controlling involves the use of potentiometer with switch. The controller is equipped with overload and short-circuit protection. In case of overload occurrence the controller will switch off automatically.
Note!
The device does not cooperate with halogen light powered by magnetic transformer, e.g. toroidal one.
In case of light level adjustment of several light source, the same powers and bulb types shall be used.

Technical data

Symbol …IRO-2
Power supply 230V- 50Hz
Tolerance of voltage supply -15 + +10%
Light control switch and regulation on potentiometer
Cooperation with load LED dimmed, halogen powered by electronic transformer,

incandescent
LED load capacity| 0 ÷ 100W (max. 10 x LED dimmed)
Halogen capacity and incandescent load| 10 + 250W
Number of connection clamps| 3
Cross section of connection cables| max 1,5 mm2
Fixing of the casing| standard flush-mounted wall box f 60mm
Temperature operation range| from -20°C to +45°C
Contamination level| 2
Dimension with external frame| 85,4×85,4×50,2
Protection index| IP 20

Warranty terms

The guarantee is provided for a term of twelve months from the date of purchase. The defective controller must be delivered to the producer or to the seller with a purchase document. The guarantee does not cover the fuse exchange, mechanical damage, damages raised by self-repair or improper use.
ASSEMBLY MANUAL

Installation

  1. Deactivate the main fuses of home installation.
  2. Check if there is the phase wire brought into the installation box.
  3. Prize the regulatory button with use of screwdriver and remove it.
  4. Push clips on side walls of the external adapter with flat screwdriver and remove it.
  5. Pull out the intermediate and external frame from the dimmer module.
  6. Connect the phase wire to the clamp with “L”.
  7. Connect the other wire to the clamp with an arrow “ ”. (In case of dual-circuit system connect the third and the fourth wire to the clamp with an arrow “ ”.)
  8. Assemble the dimmer module in the installation box with resilient clips or fastening screws that are supplied with the box.
  9.  Assembly the external frame with the intermediate frame.
  10. Assembly the dimmer and the control button.
  11. Activate the main fuses of home installation and carry out functional tests.

Electric connection scheme of the lightning controller

Note!
Assembly shall be held by a suitably qualified person with deactivated voltage and shall meet the national safety standards.
Connecting two regulators in a two-way system may damage regulators.

**PROGRAMMER GUIDE

**

All programming operations shall be carried out smoothly one by one, with the maximal time interval of 3 seconds between subsequent operations.
Minimal light level
In case of flashing light effect during dimming the minimal light level shall be increased.
Configuration of minimum light level

  1. Switch off the controller and turn the potentiometer to position MINIMUM (i.e. turn the knob all the way left).
  2. Next, restart the regulator 3 times with approximately 1 second interval between each switching on and off (pattern: on – 1s – off – 1s – on – 1s – off – 1s – on).
  3. After the above series of switches the light will start flashing. After it stops the controller will be in the CONFIGURATION mode.
  4. Within maximum next 3 seconds after the light goes off turn the knob right until the light switches on and set the minimum satisfactory light level.
  5. Leave the controller in this position for three seconds. In that time the device will “accept” and “remember” the minimum light level setting.
  6. When the light goes strong and then weak the controller goes back to its normal operation.

Operation mode
By default, the regulator operates in Mode 2. If the regulator does not operate properly (eg the lighting flashes or the desired minimum lighting level cannot be set), change the operation mode of the regulator to Mode 1.
If, after changing the operating mode from Mode 2 to Mode 1, the lighting still does not work properly, change the operating mode again to Mode 2 and check whether the regulator is working properly.
Change of operation mode

  1. Switch off the controller and turn the potentiometer to position MAXIMUM (i.e. turn the knob all the way right).
  2. Switch off and switch on the controller three times with 1 second interval between the switching on and switching off (follow the scheme: turn off – 1s – turn on – 1s – turn off – 1s – turn on – 1s – turn off – 1s – turn on – 1s).
  3. The light shall flash several times and then stop, this will mean that the controller is in the CONFIGURATION mode.
  4. To select mode no. 1 turn the knob within 3 seconds to the position MINIMUM, and then turn back tothe position MAXIMUM.
  5. To select mode no. 2 turn the knob within 3 seconds to the position MINIMUM.
  6. When the light turns on once it means the mode no.1 has been set, when the light turns on twice it means the mode no 2. has been set.
  7. After operation mode is set the device shall return to it is normal operation.

Components of the electronic lightning controller with push and rotary button for LED lamps

Karlik Elektrotechnik Sp. z o. o. I ul.
Wrzesinska 29 I 62-330 Nekola I
tel. +48 61 437 34 00 I
e-mail: karlik@karlik.pl
www.karlik.pl

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals