3onedata IES7110 Series Managed Industrial Ethernet Switch Installation Guide
- September 25, 2024
- 3onedata
Table of Contents
IES7110 Series Managed Industrial Ethernet Switch
“`html
Product Information
Specifications:
-
Model: IES7110 Series Managed Industrial Ethernet Switch
-
Models Available: IES7110-8T2GS-2P48, IES7110-8T2GS-P220
-
Ports: 8 x 100M copper ports, 2 x Gigabit SFP slots
-
Power Supply Inputs: 2 x 12~48VDC (for model I), 1 x 220VAC/DC
(for model II) -
Manufacturer: 3onedata Co., Ltd.
-
Address: 3/B, Zone 1, Baiwangxin High Technology Industrial
Park, Song Bai Road, Nanshan District, Shenzhen, 518108, China -
Website: www.3onedata.com
-
Tel: +86 0755-26702688
-
Fax: +86 0755-26703485
Product Overview:
The IES7110 Series are managed industrial Ethernet switches with
DIN-Rail mounting. They support both 100M and Gigabit speeds and
come in different models with varying port configurations and power
supply inputs.
Package Checklist:
- Industrial Ethernet switch
- DIN-Rail mounting attachment
- Power line (only for AC device)
- Warranty card
- Certification
Mounting Dimension:
Unit: mm
Note: All products in this series have the same installation
size.
Notice Before Mounting:
Before mounting the device, ensure it is not placed in areas
near water or moisture, maintain relative humidity between 5%~95%
without condensation. Check power specifications to prevent damage
due to overvoltage. Avoid direct contact with the high surface
temperature of the device.
Mounting Instructions:
-
Check if the DIN-Rail mounting kit is installed firmly.
-
Insert the bottom of DIN-Rail mounting kit into DIN-Rail, then
insert the top. -
Ensure the product is firmly installed on DIN-Rail.
Disassembling Instructions:
-
Power off the device.
-
Lift the device slightly upward and shift out the top of
DIN-Rail mounting kit. -
Shift out the bottom of DIN-Rail mounting kit.
FAQ:
Q: What should I do if any package items are damaged or
lost?
A: In case of damaged or lost items, please contact the company
or dealers for assistance.
“`
IES7110 Series Managed Industrial Ethernet Switch
Quick Installation Guide
Model I. IES7110-8T2GS-2P48 (8 100M copper ports + 2 Gigabit SFP slots + 2
12~48VDC power supply inputs) IES7110-8T2GS-P220 (8 100M copper ports
Model II. + 2 Gigabit SFP slots + 1 220VAC/DC power supply input)
3onedata Co., Ltd.
Address: 3/B, Zone 1, Baiwangxin High Technology
Industrial Park, Song Bai Road, Nanshan
District, Shenzhen, 518108, China
Website: www.3onedata.com
Tel:
+86 0755-26702688
Fax:
+86 0755-26703485
Package Checklist
Please check the integrity of package and accessories while first using the switch.
1. Industrial Ethernet switch 2. DIN-Rail mounting attachment 3. Power line (only for AC device) 4. Warranty card 5. Certification
If any of these items are damaged or lost, please contact our
company or dealers, we will solve it ASAP.
Product Overview
This series products are 100M/Gigabit managed DIN-Rail
industrial Ethernet switches. For convenience, the products of
this series adopt the following number on the left in this guide,
please confirm the number of your product:
Model III. IES7110-6T2F2GS-2P48 (6 100M copper ports + 2 100M fiber ports + 2
Gigabit SFP slots + 2 12~48VDC power supply inputs) Model IV.
IES7110-6T2F2GS-P220 (6 100M copper ports +2 100M fiber ports + 2 Gigabit SFP
slots + 1 220VAC/DC power supply input) Model V. IES7110-4T4F2GS-2P48 (4 100M
copper ports +4 100M fiber ports + 2 Gigabit SFP slots + 2 12~48VDC power
supply inputs) Model VI. IES7110-4T4F2GS-P220 (4 100M copper ports +4 100M
fiber ports + 2 Gigabit SFP slots + 1 220VAC/DC power supply input)
Panel Design
Main view and right view
Model I
Model II Model III
Rear view, bottom view and top view
Model IV
Model VI Rear view, bottom view and top view
Model III, V
Model V
Model I Rear view, bottom view and top view
Model II
Model IV, VI
1. Indicators, from left to right in turn they are: – Running indicator (RUN)
– Alarm indicator (ALARM) – Power indicator (P1/P2/PWR)
2. Gigabit Ethernet SFP slot (G1-G2) 3. Gigabit Ethernet SFP indicator
(G1-G2) 4. 100M Ethernet copper port (1-4/6/8) 5. 100M Ethernet copper port
indicator (1-4/6/8) 6. 100M Ethernet fiber port (5/7-8) 7. 100M Ethernet fiber
port indicator (5/7-8) 8. DIN-Rail 9. Wall-mounting accessories (additional
purchase
required)
10. DIP switch 11. Console port 12. Terminal blocks for relay alarm output
(RELAY) 13. Grounding screw (M3) 14. Terminal blocks for DC power input (V1+,
V1-, V2+,
V2-) 15. AC power input terminal block (N, FG, L)
Mounting Dimension
Unit: mm
Note: All products in this series have the same installation size.
Notice before Mounting:
Don’t place or install the device in area near
water or moisture, keep the relative humidity of
the device surrounding between 5%~95%
without condensation. Before powering on the
device, check the power specifications
supported by the device to prevent device
damage due to overvoltage. The device surface
temperature is high after running; please don’t
directly contact to avoid scalding. DIN-Rail Mounting
Adopt 35mm standard DIN-Rail mounting which is suitable for most industrial scenes, mounting steps are as follows:
Check if the DIN-Rail mounting kit is installed firmly. Insert the bottom of
DIN-Rail mounting kit (one side
with spring support) into DIN-Rail, and then insert the top into DIN-Rail.
Tips: Insert a little to the bottom, lift upward and then insert to the top.
Check and confirm the product is firmly installed on
DIN-Rail, then mounting ends.
Disassembling DIN-Rail
Power off the device. After lifting the device upward slightly, first shift
out the top of DIN-Rail mounting kit, and then shift out
the bottom of DIN-Rail, disassembling ends.
Notice before Powering on:
Power ON operation: First insert the power supply
terminal block into the device power supply
interface, and then plug the power supply plug and
power on. Power OFF operation: First, remove the
power plug, then remove the wiring section of
terminal block. Please pay attention to the above operation sequence.
Power Supply Connection
DC power supply
Model I, Model III and Model V
support redundant power input,
providing two power inputs, PWR1
and PWR2. You can use one or
connect two independent external
DC power supply systems. When connecting two power
supplies to the device, it could ensure the continuous and
normal operation of the device when one of the power
systems fails. The power supply has
the function of
non-polarity connection, and the device can still work normally
when it is reversely connected. Adopt 4-pin 7.62mm pitch
power input terminal blocks, the terminal block definition is
shown in the left figure. Voltage range:12/24/48VDC
(12~60VDC) AC power supply
Model II, IV, and VI adopts AC power
supply, adopts 4-pin 7.62mm pitch
power supply input terminal blocks,
and the terminal block definition is
shown in the left figure. Voltage (100~240VAC/DC).
Relay Connection
range: 220VAC/DC
Support 1 RELAY alarm information output, and adopt 2-pin
7.62mm pitch terminal blocks. The relay supports the output
of DC power supply alarm or network abnormality alarm. It
can be connected to alarm light or alarm buzzer or other
switching value collecting devices, which can timely inform
operators when the alarm occurs. The relay status is shown in
the figure below.
Device Status
Relay Contacts
Not powered on or powered off Closed
Powered on, but not working Closed properly
Powered on, and working Disconnected
Alarm Yes Yes
No
Relay
Device Status properly without triggering any
Contacts
Alarm
alarm
Powered
on, and working Closed
Yes
properly, but it triggered alarms
DIP Switch Settings
Provide 4 pins DIP switch for function settings,
where “ON” is enable valid terminal. The device
needs to be powered on again to change the
status of DIP switch.
The definitions of DIP switch are as follows:
No. Definition 1 2 Reserved
Restore Factory Settings
Operation —
Set the DIP switch
to ON,
restart the device, it will restore
to factory settings, then turn off
the DIP switch.
3
Burn Mode
This
is onfulynctifoonr
after-sales personnel to use
4
Reserved
—
Console Port Connection
The device provides 1 program debugging port based on RS232
serial port which can conduct device CLI command
management after connecting to PC. The interface adopts RJ45
port, the RJ45 pin definition as follows:
Pin No.
2
3
5
Definition TXD
RXD
GND
Checking LED Indicator
The device provides LED indicators to monitor its operating
status, which has simplified
the overall troubleshooting
process. The function of each LED is described in the table
below:
LED PWR/P1/P2
Indicate Description
ON
Power is connected and
running normally
ALARM RUN
OFF ON OFF ON OFF Blinking ON
Power supply is disconnected or running abnormally Power supply or the port link is alarming. Power supply, port link without alarm The device is powering on or the device is abnormal. The device is powered off or the device is abnormal. Blinking 1 time per second, system is running normally Ethernet port has established a valid network connection
Link/Act (1-8/G1-G2)
Blinking
Ethernet port is in an active network status Ethernet port has not
OFF
established valid network
connection
Logging in to WEB Interface
Support WEB management and configuration. Computer can
access the device via Ethernet interface. The way of logging in
to device’s configuration interface via IE browser is shown as
below:
Configure the IP addresses of computer and the device to the same network segment, and the network between them can be mutually accessed
Enter device’s IP address in the address bar of the
computer browser.
Enter device’s username and password in the login window as shown below.
Click “OK” button to login to the WEB interface of the device.
Note:
The default IP address of the device is
“192.168.1.254”. The default user name and
password of the device are “admin”. If the
username or password is lost, user can restore it to
factory settings via device DIP switch or
management software; all modified configurations
will be cleared after restoring to factory settings, so
please backup configuration file in advance. Please
refer to user manual for specific configuration
method of logging in to WEB interface and other
configurations about network management
function. Specification
Panel Gigabit SFP 100M fiber port
100M copper port
1000Base- SFP, SFP slot
100Base-FX,
optional
SC/ST/FC
10Base-T/100Base-TX, RJ45,
Automatic Flow Control, Full/Half Duplex Mode,
MDI/MDI-X Autotunning
Console port Alarm port
CLI command management port (RS-232), RJ45 2te-rpminin7a.6l 2bmlomcksp,itscuhpport 1 relay alarm output, power load capability is 1A@24VDC
Indicator
Switch Property Backplane bandwidth Cache size MAC address table Power Supply
DC power supply
AC power supply
Access terminal block
Power supply indicator, run indicator, interface indicator, alarm indicator
9.6G 2Mbit 4K
1(122/~2640/4V8DVCD),C
rinepduutn,dant dual power
built-in overcurrent protection,
support non-polarity
220VAC/DC (100~240VAC/DC),
with built-in 5.0A overcurrent
protection
4-pin 7.62mm pitch blocks
terminal
Power Consumption Model I Model II Model III Model IV Model V Model VI
No-load: 3.8W@48VDC Full-load: 4.0W@48VDC No-load: 4.1W@220VDC Full-load: 4.3W@220VDC No-load: 5.6W@48VDC Full-load: 7.8W@48VDC No-load: 5.4W@220VDC Full-load: 6.8W@220VDC No-load: 7.0W@48VDC Full-load: 8.6W@48VDC No-load: 6.8W@220VDC Full-load: 8.0W@220VDC
Working Environment
Working temperature
-40~75
Storage temperature Working humidity
Storage temperature: -40~60
5% 95% (no condensation)
Protection grade
IP40 (metal shell)
Disposal of Waste Electrical and Electronic Equipment (WEEE 2012/19/EU)
(Applicable in the EU-member states)
The crossed-out wheeled bin
symbol on the equipment or its
packaging indicates that the
product, at the end of its service life, shall not be mixed
with unsorted municipal waste
but should be collected separately, in accordance with
local laws and regulations.
A proper separate collection of end-of-life equipment for the
subsequent recycling, treatment and environmentally
compatible disposal, will help prevent potential damage to the
environment and human health,
facilitating the reuse,
recycling and/or recovery of its component materials. Private
users should contact their vendor or municipal waste
management service and ask for disposal information.
Professional users should contact their suppliers and check the
terms of their selling agreement. This product must not be
disposed of with other commercial waste. Users’ cooperation in
the correct disposal of this product will contribute to saving
valuable resources and protecting the environment.